Omega HHC230 Instruction Sheet

INTRODUCTION
The pocket size meter is used to measurement of light intensity with user selectable units of lux and fc.
SAFETY INFORMATION
It is recommended that you read the safety and operation instructions before using the absolute pressure meter.
for its intended purpose and within the parame-
ters specified. Do not use force.
acids or other aggressive substances.
3. Don’t keep in place with high Temp, or high
humidity.
4. When not use for long time remove battery.
SPECIFICATIONS
Range: 0 to 200000 lux, 0 to 18580 fc Units: lux, fc Resolution:
1 lux (0 to 19999), 10 lux (20000 to 200000) 1 fc (0 to 18580
)
Spectral re
sponse: CIE photopic.
The CIE photopic curve is an international
standard for the color response of the average
human eye.
Spectral angle: ƒ′1 < 8% Acceptance angle:
ƒ′2 <2% cosine corrected (150°)
Total accuracy for CIE standard illuminant A (2856K): ±(3%rdg + 10dgts)
CIE standard illuminant A can be realized by means of CIE standard source A, which is de­fined as: A gas-filled tungsten-filament lamp
operating at a correlated color temperature of 2856K.
Accuracy:
Stated accuracy at 23°C±5°C, <70% R.H.
Temperature Coefficient: 0.1 times the applicable
accuracy specification per °C out of 23°C±5°C.
Measurement rate: 1 times/second. Operating environment: 0°C to 50°C at <70%
R.H.
Storage temperature: -20°C to 50°C, 0 to 80%
R.H. with battery removed from meter.
Battery: 1.5V (AAA size) x 2pcs. Battery Life: 180 hours typical. Low battery indication: The “
” is displayed when the battery voltage drops below the oper­ating level.
Dimensions:
24.7mm (T) x 50.9mm (W) x 132.9 mm (H).
Weight: Approx. 116g including batteries.
OPERATIONS
There are 3 operation modes, namely Measure-
ment Mode, Set Mode and Hold Mode.
1. Turning on and off the meter:
When
power
is off, a short push on “ ” key turns on the meter and enter Measurement Mode. When power is
on, press and hold “ ” key for 2
seconds turns the power off. Right
after
power on, all the indicators on the
LCD display lights up for one second.
2. Measurement Mode:
When power is on, the meter starts measuring and refresh every second.
Changing unit:
In measurement mode, press “
” key to switch
between lux and fc.
Backlight:
In measurement mode, a short push on “
” key turns on the backlight for dark environment, it goes off automatically after 15 seconds if without further operation.
3. Set Mode:
In set mode, user can turn on/off APO function. (APO = Auto Power Off, when APO is ON, the meter power off automatically if no operation in 10 minutes) When power is off, press and hold “
” key for 2
seconds to enter Set Mode.
Short push on “
” key switches between ON and OFF. Push “MODE” key to save the setting, exit APO setting mode and enter measuring mode.
Note:
To turn off power in Set Mode abandon
the current setting and previous settings remain unchanged. If “
” indicator appeared, the setting value can works till power off but did not save to meter.
4. Hold Mode:
In Measurement Mode, short push “Mode” key to enter Hold Mode with indicator “HOLD” shows at upper left corner of LCD. Right after entering this mode, shown in the LCD is the last measurement and the reading will not be updated with new measurement. Push “Mode” key each time the display changes in following sequence: (1) Last Measurement: with indicator “HOLD”. (2) Maximum value recorded: with indicator
“HOLD” + “MAX”.
(3) Minimum value recorded: with indicator
“HOLD” + “MIN”.
(4) Maximum-Minimum value recorded: with
indicator “HOLD” + “MAX-MIN”.
(5) Average of values recorded: with indicator
“HOLD”
+ “AVG”.
(6) Exit
the Hold Mode and return to Measure-
ment Mode.
To clear the recorded values:
In Hold Mode and during viewing MAX, MIN, MAX-MIN or AVG, press and hold “Mode” key for 2 seconds, to clear the recorded data and re­turn to measurement mode.
MAINTENANCE
Installing and Replacing Battery
A. Battery Cover B. Battery
1. Power is supplied by 2pcs 1.5V (AAA SIZE).
2. The “
” appears in the display when battery
replacement is needed.
3. Push the Battery Cover and lift it in the direction as shown in the figure.
4. Remove the batteries from battery compartment.
5. Replace with 2 new AAA batteries with polarity as indicated on the bottom of Battery Compart­ment.
6. Replace the Battery Cover.
Cleaning
Periodically wipe the case with a damp cloth and
detergent, do not use abrasives or solvents.
HHC230
Light Meter
INSTRUCTION
SHEET
M5512/0418
Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
LIGHT METER
HHC230
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a trademark of OMEGA ENGINEERING, INC. © Copyright 2018 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to
cover the COST of the repair,
2. Model and serial number of
the product, and
3. Repair instructions and/or
specific problems relative to the product.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the o utside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.