Handheld Volatile Organic
Compound (VOC) Meter
HHAQ-107
U Metal-Oxide Semi-Conductor Sensor
within Vented Ball Housing Detects
Ammonia, Toluene, Ethanol, Hydrogen
Sulfide (H
U Make Total VOC Concentration
Measurements, Ambient Temperature,
Relative Humidity (RH), Dew Point and
Wet Bulb Temperatures
U Logs Up to 32,000 Data Points
U Powerful Data Logging Software
U Adjustable High VOC Concentration
Audible Alarm
U Min/Max Memory (for All Measured
Parameters) and Data Hold
U Separate Automated Procedures
for VOC Zero Adjustment and
Background Calibration
U Manually Off-Settable Temperature
and RH Sensor Drift
U Large Backlit Dual-Readout LCD
U Tripod Mountable
The HHAQ-107 is ideal for making general
measurements of mixed gas volatile organic
compound (VOC) levels as part of an indoor air quality
(IAQ) maintenance program. Much less expensive
than photo-ionization meters designed to make precise
measurements of VOC levels from a single gas.
Small and light weight with a tripod mount fitting, the
HHAQ-107 is a versatile tool for HVAC and
IAQ technicians. The meters storage capacity can be
entirely devoted to VOC readings or split 3 ways for
VOC, ambient temperature and relative humidity. The
HHAQ-107 incudes powerful data logging software for
downloading readings to a PC and printing in table or
graph form.
S) and Cigarette Smoke
2
Temperature Measurement Accuracy/Resolution:
±0.6°C (1.2°F)/0.1°
RH Measurement Range: 10 to 90% RH
RH Measurement Accuracy/Resolution: ±5% of reading at
25°C (77°F); ±7% of reading elsewhere in range/0.1% RH
Dew Point Measurement Range: -73 to 47°C
(-99.2 to 118°F)
Wet Bulb Measurement Range: -11 to 48.2°C
(12.2 to 118.8°F)
Data Logging Capacity: 32,004 points
Display Type/Size: Dual readout LCD/51 mm (2") diagonal
Auto Power-Off Trigger: 15 minutes of front-panel inactivity
(can be disabled)
Operating Temperature: 0 to 50°C (32 to 122°F) at
0 to 95% RH, non-condensing
Dimensions: 210 L x 60 W x 25 mm D (8.3 x 2.4 x 1.0")
Weight: 204 g (7.2 oz), including batteries
Power Source: (6) “AAA” batteries (included) or included
110 Vac adaptor
HHAQ-107, shown
smaller than actual size.
SPECIFICATIONS
VOC Measurement Range/Resolution:
0 to 50/0.01 ppm
VOC Warmup Time: 10 minutes first use,
2 minutes thereafter
VOC Sensor Type/Longevity: Metal-oxide semiconductor/
5 years (typical)
Temperature Measurement Range: -10 to 50°C
(14 to 122°F)
To Order
Model No. Description
HHAQ-107
MN2400
Comes complete with meter, PC-compatible data logging program
on mini-disc, USB cable, AC adaptor, soft pouch, (6) “AAA” batteries
and operator’s manual.
1
Handheld volatile organic compound
(VOC) meter
Replacement “AAA” batteries
2 per pack, 3 packs needed