Omega FTB-1400-MD-A, FTB-1400-RD-A, FTB-1400-SD-A User guide

Page 1
User’s Guide
Shop online at
omega.com
For latest product manuals:
omegamanual.info
Series FTB-1400-MD-A
FTB-1400-RD-A FTB-1400-SD-A
Page 2
OMEGAne t ®Online Service Internet e-mai l
o mega.com i [email protected]
Servicing North America:
U.S.A. : One Omega Drive, Box 4047
ISO 9001 Certied Stamford, CT 06907-0047
Canada :
Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected]
976 Bergar Laval (Quebec) H7L 5A1, Canad a Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] a
For immediate technical or application assistance:
U.S.A. and Canada : Sales Service: 1-800-826-6342/1-800-TC-OMEGA
Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
®
®
Mexico : En Espa n ˜o l: (001) 203-359-7803
e-mail: [email protected] FAX: (001) 203-359-7807 [email protected] x
Servicing Europe:
Czech Republic : Frystatska 184, 733 01 Karvina ´, Czech Republic
Germany/Austria : Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9001 Certied Northbank, Irlam, Manchester
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
Tel: + 420 (0) 59 6311899 FAX: + 420 (0) 59 6311114 Toll Free: 0800-1-66342 e-mail: [email protected]
Tel: +49 (0)7056 9398- 0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: [email protected] e
M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: [email protected]
Page 3
TABLE OF CONTENTS
Introduction ................................................................................................... 4
Features ............................................................................................................ 5
Speci cations ................................................................................................. 6
Operating the Monitor .............................................................................. 7
Advanced Programming Mode ................................................ 7
Programming ....................................................................... 7
Linearization ...................................................................... 11
Password ............................................................................12
Battery Replacement ............................................................... 13
Additional Input Options ........................................................ 13
Wiring Diagram ........................................................................ 14
Programming Menu ................................................................15
Mounting Options ...................................................................16
Troubleshooting ...................................................................... 18
Part Numbering Information .................................................. 19
Installation Drawing ................................................................ 20
Statement of Warranty ............................................................ 23
3
Page 4
INTRODUCTION
The FTB-1400 Flow Monitor is a state-of-the-art, digital signal processing  ow monitor, designed to provide the user with exceptional  exibility at a very a ordable price. Though designed for use with Omega FTB-1400  ow meters, this display can be used with almost any  ow meter producing a low amplitude AC output or contact closure signal(s).
This  ow monitor is capable of accepting a low-level frequency input for calculating  ow rate and total. These calculations can then be displayed in the desired units of measurement. All FTB-1400  ow monitors come pre-calibrated, from the factory, if ordered with an Omega FTB-1400 Flow Meter. If required, however, it can easily be re-con gured in the  eld. The monitor’s large 8 digit by .75" numeric liquid crystal display makes extended range viewing practical. The second 8 digit by .38" alphanumeric display provides for selectable units viewing in run mode and prompts for variables in program mode. Finally, the user can choose between displaying rate, total, or alternating between both rate and total.
Mode
Indicator
Programming
Keys
RUN PROGRAM
RELAY1 RELAY2
Rate / Total Display
And
Programming Choices
Units Display
And
Programming Choices
FIGURE 1
Flow Monitor
4
Page 5
FEATURES
• Displays Rate and/or Total
• Large 0.75 Inch, 8 Digit Display for Easy Viewing
• Simple, Front Panel Programming
• Various Mounting Styles Available
• 10 Point Linearization Capability
• Gas Measurement Software Included
• NEMA 4X Suitable for Outdoor Mounting
• Intrinsically Safe
• Microprocessor Based, Low Power Components
• 1.5V “D” Size Battery
• Automatic Decimal Point Locating
• Lead Zero Blinking
• Surface Mount Technology Use Throughout
5
Page 6
SPECIFICATIONS
Power Supply:
1 “D” size 1.5 volt alkaline battery
Power Consumption:
Less than 1 milliwatt
Alphanumeric Rate and Total Display:
8 digit, .75" high numeric display 8 character, .38" high alphanumeric display Fixed or toggle modes of operation for  ow rate and totalizer display
Pulsed Output Signal:
Outputs one pulse for each increment of the least signi cant
totalizer digit Max. Voltage: 30Vdc Pulse Type: Opto-Isolated open collector transistor Pulse Width ON State: 0.9V drop @ 5.0mA or 0.7V drop @ 0.1A
Magnetic Pick-up Inputs:
Frequency Range: 0 to 3500 Hz Trigger Sensitivity: 30 mV p-p Over Voltage Protected: ±30 VDC
Frequency Measurement Accuracy: ±0.1%
Temperature Drift: 50 ppm / ºC (max)
Transient Overvoltages: Category 3, in accordance with IEC664
Pollution Degree: 2, in accordance with IEC664
Mounting Classi cation:
Meter Mount: NEMA 4X Enclosure Remote Mount: NEMA 4X Enclosure Swivel Mount: NEMA 4X Enclosure
Environmental:
Operating Temperature: -22 ºF to +158 ºF (-30 ºC to +70 ºC) Humidity: 0-90% Non-condensing
Units of Measure:
Gallons, Oil Barrels, Liters, Cubic Meters, MGal, Cubic FT, MCF, MMCF Megltrs, Acre FT, Liq. Barrels, LBS, KGS
Time Intervals: Day, Hour, Minute, Second
6
Page 7
OPERATING THE MONITOR
The monitor has two modes of operation referred to as the RUN mode and the PROGRAM mode. Both the run mode and the program mode display screen enunciators con rming the state of the monitor. A quick glance at the lower left hand corner of the LCD screen will con rm operating status. Normal operation will be in the RUN mode. To access the program mode, press the MENU button until the  rst programming screen is displayed. After programming the display with the necessary information, a lock out feature can be turned on to prevent unauthorized access or changing the meter’s setup parameters.
BASIC PROGRAMMING MODE
Keys:
MENU – Switch between RUN and PROGRAM modes
UP Arrow – Scrolls through programming sub-menus in forward
direction and increments numeric variables
RIGHT Arrow – Scrolls through programming sub-menus in reverse direction and moves the active digit to the right
ENTER – Used to enter sub-menus, save programming information and in the reset process
If your monitor was ordered with an Omega  ow meter, the two components ship from the factory calibrated as a set. If the monitor is a replacement, the turbine’s K-factor has changed, or the monitor is being used with some other pulse generating device, programming will be necessary.
PROGRAMMING USING PULSE OUTPUT TURBINE
FLOW METERS
Each turbine  ow meter is shipped with either a K-factor value or frequency data. If frequency data is provided, the data must be converted to a K-factor before programming; otherwise, 10 Point Linearization must be used to program the monitor. K-factor information, when supplied, can usually be found on the neck of the  ow meter or stamped on the body. The K-factor represents the number of pulses per unit of volume. The K-factor will be needed to program the monitor readout.
7
Page 8
ENTER PROGRAM MODE – Change to program mode by pressing the MENU button once. The mode indicator will change from RUN to PROGRAM.
NOTE: If any input value exceeds the meter's capabilities for that particular parameter, the LIMIT indicator will begin to  ash indicating an invalid entry. Press ENTER once to return to the parameter’s entry screen to reenter the value.
SELECT THE METER SIZE – At the METER prompt, press the ENTER button once. The current meter size number will begin to  ash. Using the arrow keys, scroll through the size choices until you  nd the bore size of your meter. Press ENTER once to save the meter size choice.
NOTE: The meter connection size and the bore size are di erent. For example, many of the 1” NPT turbines have bore sizes that range from 3⁄8” up to 1”. Be sure to use the correct bore size or the meter will report incorrect  ows and totals.
Mode
Indicator
Programming
Keys
RUN PROGRAM
RELAY1 RELAY2
Rate / Total Display
And
Programming Choices
Units Display
And
Programming Choices
FIGURE 2
Flow Monitor
8
Page 9
SELECT THE DISPLAY FUNCTION – The monitor can display RATE or TOTAL or alternate between BOTH rate and total. At the DISPLAY prompt, press the ENTER key once. The monitor now shows the display mode currently in e ect. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate display mode, use the arrow keys to scroll to the desired display mode and press ENTER to save the choice.
SELECT THE RATE UNITS OF MEASURE – The monitor allows the choice of many common rate units. (See Speci cations for a complete listing of the unit choices.) At the RATE UNT prompt, press the ENTER key once. The monitor now shows the rate units of measure the display is currently set for. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate unit, use the arrow keys to scroll to the desired rate unit and press ENTER to save the choice.
SELECT THE RATE [TIME] INTERVAL – The term Rate implies that something is occurring over a period of time. Most people are familiar with the rate of speed of a car reported in miles per hour (MPH). The same concept holds true for a  ow meter. The time choices are SEC (seconds), MIN (minutes), HOUR (hours), and DAY (days). At the RATE INT prompt, press the ENTER key once. The monitor now shows the time interval the display is currently set for. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate time interval, use the arrow keys to scroll to the desired time interval and press ENTER to save the choice.
NOTE: If  ow rate is the only measurement of interest, skip to KFAC UNT to complete the programming process.
SELECT THE TOTAL UNITS OF MEASURE – If a  ow amount is desirable, the units for the total must  rst be chosen. The monitor allows the choice of many common totalization units. (See Speci cations for a complete listing.) At the TOTL UNT prompt, press the ENTER key once. The monitor now shows the total units of measure the display is currently set for. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate unit, use the arrow keys to scroll to the desired totalization unit and press ENTER to save the choice.
NOTE: This unit of measure does not have to re ect the rate unit you have previously chosen. (Example: Rate Units = Gallons, Total Units = Barrels).
9
Page 10
SELECT THE TOTAL’S DISPLAY MULTIPLIER – The monitor has a very versatile display that has the ability to accumulate the  ow total in multiples of ten. For example, if the most desirable totalization unit is 1,000 gallons, the monitor can easily be set up for this requirement. Once the unit is back in RUN mode, every time the total display is incremented by one digit the actual total would be an additional 1,000 gallons. At 1,000 gallons the total display would read 1, at 3,000 gallons the total display would read 3, etc. This feature eliminates having to look at a total, counting the digits and mentally inserting commas for each 1000 multiple.
At the TOTL MUL [Multiple] prompt, press the ENTER key once. The monitor now shows the multiplier the total display is currently set for. If the current selection is correct, press the ENTER key to advance to the next parameter. To change to an alternate multiplier, use the arrow keys to scroll to the desired multiplier unit and press ENTER to save the choice.
Multiplier Choices – 0.01, 0.1, 1, 10, 100, 1000, 10000, 100000, and
1000000 Units.
NOTE: Unless otherwise speci ed, Omega FTB-1400 turbine  ow meters are supplied with K-factors measured in pulses per gallon (PUL/GAL).
ENTER THE METER’S K-FACTOR UNIT – Directly after the METER size is selected, the display’s K-factor unit must be chosen. Use the UP arrow key to select your K-factor unit. For meters calibrated in gallons, use PUL/GAL (pulses per gallon); for meters calibrated in cubic meters, use PUL/M3 (pulses per cubic meter), etc. Press ENTER to save the K-factor unit and advance to the next parameter.
SCALE FACTOR – At the SCALE F prompt, press the ENTER key once. The current Scale Factor will begin to  ash. If the current selection is correct, press the ENTER key to advance to the next parameter. The scale factor is used to force a global change to all variables. For example, under operating conditions the display is reading a consistent 3% below the expected values at all  ow rates. Rather than changing all parameters individually, the scale factor can be used to compensate for the 3% o set. The scale factor would be set to 1.03 to correct the readings. The range of scale factors is from 0.5 to 1.5. The default scale factor is 1.00.
10
Page 11
METER TYPE – At the METERTYP prompt, press the ENTER key once. The current meter type will be displayed as “Liquid” or “GAS”. If the current selection is correct, press the ENTER key to advance to the next parameter. If “GAS” is selected you must then enter your Operating Pressure and Operating Temperature before advancing to the next parameter.
DAMPING FACTOR – At the DAMPING prompt, press the ENTER key once. The current Damping setting will begin to  ash. If the current selection is correct, press the ENTER key to advance to the next parameter. The Damping Factor is increased to enhance the stability of the  ow readings. Damping values are decreased to allow the  ow meter to react faster to changing values of  ow. This parameter can take on any value between 0 and 99 with 0 being the default.
TOTALIZER PULSE OUTPUT – The pulse output parameter can be either enabled or disabled. When enabled this output generates 20mS duration pulse for every time the least signi cant digit of the totalizer increments (20Hz Max). The amplitude of the pulse is dependent on the voltage level of the supply connected to the pulse output and is limited to a maximum 30 VDC.
LINEARIZATION – Enhanced accuracy can be obtained by linearization of the display. The linearization routine will accept a maximum of ten points. Linearization requires additional calibration data from the meter to be used with the monitor. Typically, calibration information can be obtained in three,  ve, and ten points from the  ow meter’s manufacturer. If linearization is not needed, pressing the RIGHT arrow key will take you to the next parameter
Number of Points – At the LINEAR prompt, press ENTER once. The
NUM PTS number will be displayed. Press ENTER to set the number
of points you wish to use. Again, the UP arrow key increments
the value and the RIGHT arrow moves the cursor between digits.
When the number of points has been input, press the ENTER key
once to move to the  rst linear segment.
Press the ENTER key once and the  rst linear point’s frequency
input will begin to  ash (FREQ 1). Enter the frequency for the  rst
linear point using the arrow keys. When the frequency value input
has been completed, press ENTER once again to change to the
coe cient value for the  rst linear point.
11
Page 12
The coe cient is the value applied to the nominal K-factor to
correct it to the exact K-factor for that point. The coe cient is
calculated by dividing the actual K-factor for that point by the
average K-factor for the  ow meter.
Coe cient = Actual K-factor ÷ Average K-factor
At the COEFF prompt, enter the coe cient that corresponds to the
frequency value previously entered. Press ENTER once to move to
the next scaling point.
Continue entering pairs of frequency and coe cient points until
all data has been entered. Press the MENU key twice at the NUM
PTS prompts to exit to the LINEAR prompt. Press the RIGHT arrow
key to move to the next parameter.
PASSWORD – Password protection prevents unauthorized users from changing programming information. Initially, the password is set to all zeros. To change the password, press ENTER once at the password prompt. The  rst digit of the password value will begin to  ash. Using the arrow keys as previously described, enter the password value. Pressing ENTER once will store the password and take you back to the RST PSWD screen.
NOTE: This password will allow the operator to manually reset totals.
RST PSWD – Reset Password protection prevents unauthorized users from manually resetting the  ow monitor’s accumulated totals. Initially, the password is set to all zeros. To change the password, press ENTER once at the password prompt. The  rst digit of the password value will begin to  ash. Using the arrow keys as previously described, enter the password value. Pressing ENTER once will store the password and take you back to the METER size screen, pressing MENU exits the program mode. The FTB-1400 Flow Monitor is now ready for use with its companion meter. Note: Entering a password in the Password screen and leaving the password blank in the RST PSWD screen would allow for total resets (not requiring password) and restrict programming modi cation.
RESET TOTAL – To reset the monitor total display, in run mode press the MENU and ENTER simultaneously until TOTAL RST starts to  ash. The TOTAL RST will stop  ashing and the display will return to the run mode at the conclusion of the procedure.
12
Page 13
STORE TOTAL – The current total can be manually stored in the monitor’s  ash memory. This procedure may be desirable prior to changing the settings or replacing the battery. Press and hold the ENTER key for 2 seconds. The display will respond with a  ashing TOTALSVD and then return to the run mode.
AUTOMATIC STORE TOTAL – The monitor is equipped with a store total feature that works automatically, saving the current total to  ash memory once per hour and just before a low battery condition turns the unit o .
BATTERY REPLACEMENT
Battery powered monitors use a single 1.5V, “D” size, alkaline battery. When replacement is necessary, use a clean fresh battery to ensure continued trouble-free operation. It is recommended that the total be saved to memory before the battery is removed. (See STORE TOTAL above.)
Unscrew the two captive screws on the front panel to gain access to the battery. Replace the battery being sure to observe the proper polarity, and then re-fasten the front panel.
ADDITIONAL INPUT OPTIONS
The FTB-1400 Flow Monitor is capable of receiving magnetic pick-up input (small signal sine wave) or a contact closure input (pulse). Since Omega FTB-1400 Flow Meters utilize a magnetic pick-up, the monitor is shipped con gured for magnetic pick-up input. To change to a contact closure input, remove JP2 from the top two pins and jumper them to the bottom two pins. See Figure 3 on page 14.
13
Page 14
Keypad
Connector
J2
12345
JP2
Mag Input
Pulse Inuput
20 mS Pulse
14
+30 VDC (Max)
10K
123456
-
+
Pulse Out Freq. In4-20 mA
FIGURE 3
Wiring Diagram
+ -+
N/C N/C
TB1
-
Magnetic Pickup
Page 15
BPD/BBL
M3PH/M3 M3PD/M3
PUL/GAL PUL/FT3PUL/LTRPUL/M3
LPM/LIT
GPM/GAL
BOTH TOTAL RATE TEST
PULS ON PULS OFF
IO/SETUP
METER
15
K Factor Units
K FACTOR
Units
Basic Programming Menu
DSP
FIGURE 4
Pulse Output
PASSWORD
RST PSWD
Page 16
MOUNTING OPTIONS
8.93"
7.00"
5.75"
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
METER DISPLAY
7.00"
5.75"
3.93"
4.30"
7.00"
16
2.40" TYP.
2.25" TYP.
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
REMOTE DISPLAY
Page 17
3.93"
5.75"
SWIVEL MOUNT
RUN PROGRAM
RELAY1 RELAY2
MENU ENTER
7.00"
12.25"
17
Page 18
TROUBLESHOOTING GUIDE
Trouble Remedy
No LCD Display
No Rate or Total Displayed
Flow Rate Display Interprets Reading Constantly
Flow Rate Indicator Bounces
• Check battery voltage. Should be 1.5 Vdc. Replace if low or bad.
• Check connection from meter pick-up to display input terminals.
• Check turbine meter rotor for debris. Rotor should spin freely.
• Check programming of  ow monitor.
• This is usually an indication of external noise. Keep all AC wires separate from DC wires.
• Check for large motors close to the meter pick-up.
• Check for radio antenna in close proximity.
• Try disconnecting the pick-up from the monitor pig tail. This should stop the noise.
• This usually indicates a weak signal. Replace pick-up and/or check all connections.
• Examine K-factor.
DEFAULT K-FACTOR VALUES
Meter Size Default K-factor Lower Limit Upper Limit
0.375 20,000 16,000 24,000
0.500 13,000 10,400 15,600
0.750 2,750 2,200 3,300
0.875 2,686 2,148 3,223
1.000 870.0 696.0 1,044
1.500 330.0 264.0 396.0
2.000 52.0 41.6 62.0
3.000 57.0 45.6 68.0
4.000 29.0 23.2 35.0
6.000 7.0 5.6 8.0
8.000 3.0 2.4 4.0
10.000 1.6 1.3 2.0
18
Page 19
PART NUMBERING INFORMATION
FTB - 1400 - X D - A
Mounting Style
M - Meter Mount R - Remote Mount S - Swivel Mount
REPLACEMENT PARTS
Component Part Number
Keypad B260713
Battery B280601
Battery Tie Wrap B228036
Pick-up Cable B222-121
Desiccant Bag B260630
PVC Union B220016
PVC Reducer Bushing B220056
Rubber Washer B228207
Steel Lock Washer B220018
PCB Shield (battery units) B280603
Desiccant Shield B280680
Cord Grip B220103
19
Page 20
SWIVEL MOUNT
METER MOUNT OR
METER MOUNT
OR SWIVEL MOUNT
SCALE: .75 = 1
SWIVEL MOUNT DETAIL
WIRE HARNESS
FTB-1400 SERIES
TURBINE METER
WIRE HARNESS
-+
+ -
REMOTE CABLE WITH STRAIGHT AMPHENOL
CONNECTOR OR REMOTE CABLE WITH
MAGNETIC PICK-UP
90° AMPHENOL CONNECTOR
INSTALLATION DRAWING
MAGNETIC PICKUP
10 FT. TO MAX. 100 FT.
STRAIGHT TO TURBINE
CONNECTOR 90° OR
OPTIONAL AMPHENOL
20
Page 21
NOTES
21
Page 22
NOTES
22
Page 23
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moistur e or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
RETURN REQUESTS/INQUIRIES
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2008 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
23
RETURNS, please have
FOR NON-WARRANTY REPAIRS, OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific problems
relative to the product.
consult
Page 24
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
 
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
 
Wire: Thermocouple, RTD & Thermistor
 
Calibrators & Ice Point References
 
Recorders, Controllers & Process Monitor s
 
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
 
Transducers & Strain Gage s
 
Load Cells & Pressure Gages
 
Displacement Transducers
 
Instrumentation & Accessories
FLOW/LEVEL
 
Rotameters, Gas Mass Flowmeters & Flow Computers
 
Air Velocity Indicators
 
Turbine/Paddlewheel System s
 
Totalizers & Batch Controllers
pH/CONDUCTIVITY
 
pH Electrodes, Testers & Accessories
 
Benchtop/Laboratory Meters
 
Controllers, Calibrators, Simulators & Pumps
 
Industrial pH & Conductivity Equipment
SM
DATA ACQUISITION
 
Data Acquisition & Engineering Softwar e
 
Communications-Based Acquisition System s
 
Plug-in Cards for Apple, IBM & Compatibles
 
Datalogging System s
 
Recorders, Printers & Plotters
HEATERS
 
Heating Cabl e
 
Cartridge & Strip Heaters
 
Immersion & Band Heaters
 
Flexible Heaters
 
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
 
Metering & Control Instrumentation
 
Refractometers
 
Pumps & Tubing
 
Air, Soil & Water Monitor s
 
Industrial Water & Wastewater Treatment
 
pH, Conductivity & Dissolved Oxygen Instrument s
M-4521/0310
Loading...