Omega FP-5060 User Manual

User’s Guide
Shop online at
www.omega.com
e-mail: info@omega.com
FP-5060
Series Micro-Flow Sensors
OMEGAnet® Online Service Internet e-mail
www.omega.com info@omega.com
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certifi ed Stamford CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada: 2 Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: En Español: (001) 203-359-7803 e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
®
®
®
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl
Czech Republic: Rudé arm
TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France: 11, rue Jacques Cartier, 78280 Guyancourt, France
TEL: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de
United Kingdom: 2 One Omega Drive, River Bend Technology Centre
ISO 9002 Certifi ed Northbank, Irlam, Manchester
M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-48 e-mail: sales@omega.co.uk
.
dy 1868, 733 01 Karvin. 8
page 2
The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifi cations without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
OMEGA FP-5060 Series Micro Flow Sensor
OMEGA FP-5060 Series Micro-Flow Sensors
SAFETY INSTRUCTIONS
1. Do not remove from pressurized lines.
2. Do not exceed maximum temperature/pressure specifi cations.
3. Do not install/service without following installation instructions (see sensor manual).
4. Wear safety goggles and faceshield during installation/service.
5. Do not alter product construction.
6. Failure to follow safety instructions could result in severe personal injury!
1. Instrument Wiring
OMEGA FP-5060 Series Sensor
OMEGA FP-90 Series, FPM-5500,
Black (5 to 24 VDC)
Red (Signal out)
Shield (DC return)
Black
Shield
Red
Note: A 10 kΩ pull-up resistor is required as shown, if
not provided internal to the instrument. Contact OMEGA Technical Support for assistance.
10 kΩ
+
-
Gnd.
Input
FPM-9020A
Blk Power
Red Freq. input
Shld Gnd
5 to 24 VDC
Other instrument
Technical Notes:
Use 2-conductor twisted-pair shielded cable for cable splices up to 300 m (1000 ft) max.
Maintain cable shield through cable splice.
Route sensor cable away from AC power lines.
AUX power required when used with any OMEGA FP90 Series Flow Transmitter.
Other
Instrument
2. Recommended Sensor Position
30°30°
Recommended
mounting angles
Technical Notes:
• Horizontal surface mount (±30 °) recommended for optimum performance.
• Suitable for clean fl uids only. Suspended solids will cause mechanical failure.
• ¼ in. NPT or ISO 7/1 - R¼ (male) port connections
• NEMA 4X/IP65 splashproof enclosure
OMEGA FP-5060 Series Micro Flow Sensor
Vertical mounting
not recommended
page 3
3. Surface Mount Instructions
Remove sensor then use correct
2
screws for panel material.
#6 or M3 metric
screws recommended
Mounting surface
4. Fitting Installation
CAUTION:
• Maximum pipe fi tting torque: 10 ft - lbs (13 N m).
• DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports.
1
Pipe fittingPipe
120°
Mounting surface (top),
68 mm (2.68 in.) bolt circle
FP-5060
Mounting surface (side)
Pipe fitting Pipe
Sealant
Technical Notes:
Compatible fi ttings (customer supplied): Female union (shown), reducer, or hose barb type.
Always apply thread sealant to sensor port threads to prevent leakage.
5. Calibration
The K-Factors listed below represent the number of pulses the sensor will generate for each engineering unit of fl uid which passes. They are listed in U.S. gallons, liters and mL by sensor model:
Sensor
Model
FP-5061 9950 2629 2.629
FP-5062 9950 2629 2.629
FP-5063 3160 834.9 0.835
FP-5064 3160 834.9 0.835
PULSES PER
U.S. GAL
PULSES PER
LITER
PULSES PER
mL
page 4
OMEGA FP-5060 Series Micro Flow Sensor
6. Specifi cations
General
Flow range: 5061 and 5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm) 5063 and 5064: 1.13 to 12.11 lpm (0.3 to 3.2 gpm)
Linearity: ±1.2% of full range Repeatability: ±0.5% of full range Connections: ¼ in. NPT (male) or ISO 7/1 - R¼ (male) Cable length: 8 m (25 ft.), can splice up to 300 m (1000 ft.) max. Cable type: 2-conductor twisted pair w/shield (Belden 8451) Weight: 250 g (9.6 oz.)
Wetted Materials
• Sensor body and cover: 40% glass fi lled Polyphenylene Sulfi de
• Rotor: PEEK, natural, unfi lled
• Rotor O-ring: Viton®
• Cover O-ring: Viton®
psi
25 20 15 10
bar
1.7
1.4
1.0
0.7
0.3
5
0
0
FP-5061/FP-5062 FP-5063/FP-5064
Pressure Drop Across Sensor vs. Flow Rate
0 1.9 3.8 5.7 7.6 9.5 11.4
0 0.5 1 1.5 2 2.5 3
Electrical
Supply voltage: 5 to 24 VDC, regulated Supply current: 10 mA max. Output type: Open-collector NPN transistor, 10 mA max sink
Quality Standard
• Manufactured under ISO 9001 and ISO 14001
Fluid Conditions
Max. pressure/temperature: 0 to 80°C (32 to 176°F) @ 5.5 bar (80 psi) max
L/m
gpm
Dimensions
Top View
100 mm (3.94 in.)
Mounting tabs for metric M3 or standard #6 screws on 68 mm (2.68 in.) bolt circle
OMEGA FP-5060 Series Micro Flow Sensor
Side View
36 mm (1.42 in.)
81 mm
(3.2 in.)
page 5
NOTES:
page 6
OMEGA FP-5060 Series Micro Flow Sensor
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product
2. Model and serial number of the product under
3. Repair instructions and/or specifi c problems relative
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This aff ords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2000 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated,
or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
was PURCHASED,
warranty, and
to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the
repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specifi c problems relative
to the product.
OMEGA FP-5060 Series Micro Flow Sensor
page 7
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at www.omega.com
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
6-2000.090-OM/(E-03/07) M-2579/0307
Loading...