DPCI 0-TL Totalizer
662/0693
Ml
POWER
Internal battery: 3 V, lithium
Life expectancy: 5 years +
Replacement Pan:
PHYSICAL
Operation Temperature: 0”
Storage Temperature: -20
Operating Humidity: 90% Non-condensing
Weight: 2.2 oz. net
Display Size:
Front Panel Rating: NEMA-4X
with gasket provided.
Case Material: Cycolac X-17
TOTALIZER
Type: UP counting
Digits: 8
k-
I
.43”
high
(74.93mm)
2.95”
DPClO-BAT
-
55°C
-
70°C
when mounted
-4
I
T
1.57
(39.87mm)
1
<
Recommended
Panel Cutout
I
lnputA(Terminal3) highspeedinputrequiringavoltagesource
ee
a current sourcing sensor or a current sinking sensor
such
used with the provided pull up resistors.
RESET INPUT (Terminal 4) designed for contact closures to dc
common.
Speed: 0 to 10
Minimum Low Time: 80 microseconds
Minimum High Time: 20 microseconds
above
(The
Input Impedance:
Voltage Thresholds: Low 0 to 1.2 V dc
Minimum Low: 0.25 to 1 second (maintained)
The required pulse
factor and number of digits displayed.
Voltage Thresholds: Low 0 to 0.4 V dc
(68mm)
2.677”
-+
T
1.299”
(33mm)
I
__!I
kHz
times are with a 0 to 5.0 V swing.)
2kS2
above 5 V dc
High 2.0 to 28 V dc
Max. High 28 V dc
width
varies with count speed, scale
High 2.0 to 28 V dc
DC COMMON (Terminal 1)
COUNT INPUTS
Input B (Terminal 2) low speed input designed for contact
closures to common
Speed: O-40 Hz
Minimum
Minimum High Time: 20
Impedance: 101
Voltage Thresholds:
Low Time: 5
kR
Low 0 to 0.4 V dc
High 2.0 to 28 V dc
Max. High 28 V dc
msec
msec
FRONT PANEL RESET ENABLE (Terminal 5)
COUNT ACCURACY
Operation: Level sensitive (maintained)
100%
when operated within specifications.
INTRODUCTION
Your
OMEGA
high-contrast eight-digit
key can be disabled. A remote-reset terminal is provided.
DPClO-TL
is an UP
LCD display. The front-panel reset
counting totalizer with a
Count
(Voltage
/
rl
occurs
on this
applied to terminal)
edge of the pulse
Ir
FRONT VIEW
REAR VIEW
AST 4
8digit LCD
Display
Ml
Reset
Plastic
front panel
sealed to
meet
NEMA 4X
APPLICATIONS
This totalizer is intended for simple totalizing applications.
One count input pulse per item is necessary. The only
decisions to be made are:
1.
2.
OPERATION
The totalizer display has lead-zero blanking. No decimal
point is available.
-
Do you use the high or low speed input?
Do you want the front panel reset button active?
Terminal 3 is pulled down to common. When
supplies voltage to this terminal, one count is registered on
the display. The sourcing signal must supply at least
+28
+2.0
V dc but no more than
Note:
When a sourcing signal is applied to terminal 3, a
power assist feature of the
battery.
Terminal 2 is the low-speed, current-sinking count input
designed to be used with a contact closure to ground. It has
a maximum count speed of 20 Hz. Inputs into this terminal
are counted on the negative-going edge.
Contact Closes
$gjiijjq
Terminal 2 is pulled up to
pulling the voltage down to
registered.
RUN MODE
Screens
The totalizer screen is the only screen available on this
model.
Front Panel Reset Enable
r
V dc.
DPClO-TL
Contact
+3 V dc. When a contact closes,
.4
V dc or less, one count is
a sensor output
extends the life of the
Opens
MOUNTING
Gasket
Installed?
Iff
Separate contact and solid state count inputs are provided.
The solid state input (terminal 3) requires a current-sourcing
sensor and can count up to 10
are counted on the positive-going edge.
flJ
kHz.
Inputs into this terminal
Page 2
(
GNDl
5 Enable/R
t
1
Note: The front-panel reset button comes
the factory. To enable
from terminal 5 to ground, terminal 1.
The reset terminal on the rear panel is still active when
Note:
the front reset button is disabled.
PROGRAM MODE
There is no program mode for this model.
the button, install a jumper wire
t
disabled from