a current sourcing sensor or a current sinking sensor
suchused with the provided pull up resistors.
RESET INPUT (Terminal 4) designed for contact closures to dccommon.
Speed: 0 to 10 Minimum Low Time: 80 microsecondsMinimum High Time: 20 microseconds
above
(The Input Impedance:
Voltage Thresholds:Low 0 to 1.2 V dc
Minimum Low: 0.25 to 1 second (maintained)The required pulse factor and number of digits displayed.Voltage Thresholds:Low 0 to 0.4 V dc
(68mm)
2.677”
-+
T
1.299”(33mm)
I
__!I
kHz
times are with a 0 to 5.0 V swing.)
2kS2
above 5 V dc
High 2.0 to 28 V dcMax. High 28 V dc
width
varies with count speed, scale
High 2.0 to 28 V dc
DC COMMON (Terminal 1)COUNT INPUTSInput B (Terminal 2) low speed input designed for contact
closures to common
Speed: O-40 HzMinimum
Minimum High Time: 20 Impedance: 101 Voltage Thresholds:
Low Time: 5
kR
Low 0 to 0.4 V dcHigh 2.0 to 28 V dc
Max. High 28 V dc
msec
msec
FRONT PANEL RESET ENABLE (Terminal 5)
COUNT ACCURACY
Operation: Level sensitive (maintained)
100%
when operated within specifications.
INTRODUCTION
Your
OMEGA
high-contrast eight-digit
key can be disabled. A remote-reset terminal is provided.
DPClO-TL
is an UP
LCD display. The front-panel reset
counting totalizer with a
Count
(Voltage
/
rl
occurs
on this
applied to terminal)
edge of the pulse
Ir
FRONT VIEW
REAR VIEW
AST 4
8digit LCDDisplay
Ml
Reset
Plasticfront panelsealed tomeetNEMA 4X
APPLICATIONS
This totalizer is intended for simple totalizing applications.One count input pulse per item is necessary. The onlydecisions to be made are:
1.
2.
OPERATION
The totalizer display has lead-zero blanking. No decimal
point is available.
-
Do you use the high or low speed input?Do you want the front panel reset button active?
Terminal 3 is pulled down to common. When
supplies voltage to this terminal, one count is registered on
the display. The sourcing signal must supply at least
+28
+2.0
V dc but no more than
Note:
When a sourcing signal is applied to terminal 3, apower assist feature of the battery.
Terminal 2 is the low-speed, current-sinking count inputdesigned to be used with a contact closure to ground. It hasa maximum count speed of 20 Hz. Inputs into this terminalare counted on the negative-going edge.
Contact Closes
$gjiijjq
Terminal 2 is pulled up to pulling the voltage down toregistered.
RUN MODE
Screens
The totalizer screen is the only screen available on thismodel.
Front Panel Reset Enable
r
V dc.
DPClO-TL
Contact
+3 V dc. When a contact closes,
.4
V dc or less, one count is
a sensor output
extends the life of the
Opens
MOUNTING
Gasket
Installed?
Iff
Separate contact and solid state count inputs are provided.The solid state input (terminal 3) requires a current-sourcingsensor and can count up to 10are counted on the positive-going edge.
flJ
kHz.
Inputs into this terminal
Page 2
(
GNDl
5 Enable/R
t
1
Note: The front-panel reset button comes
the factory. To enable
from terminal 5 to ground, terminal 1.
The reset terminal on the rear panel is still active when
Note:
the front reset button is disabled.
PROGRAM MODE
There is no program mode for this model.
the button, install a jumper wire
t
disabled from
WIRING RECOMMENDATIONSWIRING DIAGRAMS
Following these suggestions will increase noise immunity
and extend the life of the product.
Cable:
Make the connection between the count source andthe totalizer with a two-conductor shielded cable. Connectthe shield to earth ground at one end only.
Relay Coil Suppression:
count source, suppress the relay coil. This can be accom-plished with an RC network for AC coils or a diode for DCcoils.
Mounting:
inductive devices. Supply enough ventilation to keep thetotalizer operating within the temperature specifications.
BATTERYSAFETY
The lithium battery that powers your device contains inflam-mable materials such as lithium organic solvent, and otherchemical ingredients. Explosion or fire may result if thebattery is not handled correctly.
these guidelines:
Do
not mount he totalizer nearasolenoidorother
If a relay contact is used as a
To
avoid an accident follow
CONTACT CLOSURE COUNT INPUT
SOLID STATE COUNT INPUT
CURRENT SOURCING SENSOR
6
@
5 Enable/R
\?
SOLID STATE INPUT
CURRENT
SlNKtNG
SENSOR
RST4
INAINB2
GNDl
@@
@
@
-I-
‘“I
;\
J
+28
to
V dc
+6
??
Do not stack or jumble up batteries
??
Do not heat batteries above 95°C
??
Do not disassemble batteries
??
Do not recharge lithium batteries
??
Do not apply pressure to, or deform batteries
??
Do not solder to batteries
??
Do not dispose of batteries in fire
??
Insert battery with correct polarity
Terminal
12
3
4
5
FunctionGround
Input B
Count
Input
Count Input
Reset
Reset Enable
Operation
Use with Contact Closure to Ground
Input
Maximum 20 Hz Count Speed
with Current Sourcing Sensor
Use
A
maximum 10
Connect to ground to ResetTotalizer. This is a maintained or
Level Sensitive Reset
Key
Connect to Ground to Enable
Reset Key
kHz Count Speed
REMOTE RESET
RST 4
INAINB2
Enable/R
@
5
4
FRONT PANEL RESET ENABLE
GND
t
1
Page 3
REPLACEMENT PARTS
DPClO-BATBattery46066-21053300-241
GasketMounting Clip
28772-200Mounting Screw
OTHER OMEGA MINI COUNTER PRODUCTSDPCl
0-CS
Add/Subtract Totalizer
(Solid State Input)
DPCl O-CC
Add/Subtract Totalizer
(Contact Input)DPClO-QTDPClO-RMDPClO-RT
Quadrature Indicator
Ratemeter
Ratemeterflotalizer
OMEGA warrants this unit to be free of defects satisfactory service for a period of 13
anadditionalone(l)monthhandling and shipping time. This each product. Customer Service Department will issue an Authorized Return phone or written request.be repaired or replaced at no charge. However, this WARRANTY is VOID
evidence of having been tampered with or shows evidence of being damaged as a result of
excessive corrosion: or current, heat, moisture tion;misuseorotheroperatingconditionsoutsidsofOMEGA’scontrol. Componentswhichwearor which are damaged by misuse are not warranted. These include contact points, fuses, andtriacs.
We are glad to offer
OMEGA only warrants that the parts of defects.
OMEGA MAKES NO OTHERWHATSOEVER, EXPRESSED OR
WARRANTIES INCLUDING ANY WARRANTY OF FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF
the total
warrantv,the purchase price of the component upon which liability is based.In no event shallOMEGA be liable for consequential, Incidental or
Every precaution for accuracy has been taken in the preparation of this manual, however.OMEGAENGINEERING.INC.neitherassumesresponsibilityforanyomissionsorerrorsthatmavappear nor assumes liability for any damages that result from the use of the products inaccordance with the information contained in the manual.
lftheunitshouldmalfunction,it
negligence, indemnification.
Upon examination by OMEGA, if the unit is found to be defective it will
suggestions on the use of our various products. Nevertheless
LIABILIM:
months from date of purchase. OMEGA Warranty adds
graceperiodtothenormal
ensuras
WARRANTtES
IMPUED, EXCEPT THAT
The
remedies of buyer set forth herein are exclusive and
resPect
RETURN REQUESTS
Direct all warranty and repair requests/inquiries to the OMEGA ENGINEERING Customer ServiceDepartment. Call toll free in the USA and Canada: l-800-622-2378, FAX: tional:203-359-1669,
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, BETURN(ARINUMBEA FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOIDPROCESSING DELAYS). The assigned AR number should then be marked on the outside of thereturn package and on any correspondence. Please have the following information availableBEFORE contacting OMEGA:
product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement ispossible. That way our customers get the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING. INC.Q
Copyright 1993 OMEGA ENGINEERING, INC. All rights resewed including illustrations.NothinginthismanualmaybereproducedinanYmanner,eitherwhollyorinpartforanypurposewhatsoever without written permission from OMEGA ENGINEERING, INC.
FAX: 203-359-7807.
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems you are having with the
in
materials and workmanship and to give
ono(l)yearproductwanantytocovar
our
customers receive maximum coverage on
that
mustbereturnedtothefactoryforevaluation.
or
vibration; improper specification;
manufacturad
OR
to thii order, whether based on contract,liabilitv of OMEGA with