Omega Engineering DFG81, DFG82 User Manual

www.omega.com
e-mail: info@omega.com
User’s Guide
DFG81 AND DFG82
Mechanical Force Gauges
Servicing North America:
USA: One Omega Drive, Box 4047
TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico: TEL: (001) 800-826-6342 FAX: (001) 203-359-7807
En Espan˜ ol: (001) 203-359-7803 e-mail: espanol@omega.com
info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 6418405 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: nl@omega.com
Czech Republic: Rudé armády 1868, 733 01 Karviná 8
TEL: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free in Czech Republic: 0800-1-66342 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400 FAX: +33 (0)130 699 120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 3017 FAX: +49 (0)7056 8540 Toll Free in Germany: 0800 TC-OMEGA
SM
e-mail: germany@omega.com
United Kingdom: One Omega Drive, River Bend Technology Centre
ISO 9002 Certified Northbank, Irlam, Manchester
M44 5EX, England TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in England: 0800 488 488 e-mail: sales@omega.co.uk
OMEGAnetSMOn-Line Service Internet e-mail
http://www.omega.com info@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
PRECAUTIONS
1. Do not exceed capacity of unit.
2. Do not use the tension shaft to measure compression or the compression shaft to measure tension.
3. When mounting DFG81/DFG82 to stand, use M3 mounting screws with a maximum insertion depth of 8mm into the gauge.
4. Accuracy may be affected if unit is exposed to high humidity, dust or extreme shock.
5. Do not apply oil or chemical soap which causes corrosion or dust adhesion.
6. Do not remove warranty seal or disassemble gauge. Disassembly voids warranty.
GENERAL OPERATION
1. Press Peak Switch OFF.
2. Hand tighten (no tool!) selected attachment to the measuring shaft.
3. Rotate Tare Ring to read “0” to tare the weight of attachment and measuring shaft orientation.
4. Begin measuring.
Real Time Mode: the Peak Switch is OFF and the gauge displays force as it changes.During Real
Time Mode, you can hold a critical reading by turning the Peak Switch to the ON position.
Peak Mode: the Peak Switch is ON and the gauge will retain highest reading taken which will not
change until a higher value is measured.Turn the Peak Switch OFF to zero the gauge and turn it ON again to measure Peak values.
Tension measuring shaft
Peak switch
This switch activates or clears peak hold reading.
Tare ring
Compression measuring shaft
ON
Pounds Kilograms Newtons
Model
Capacity
Model
Capacity
Model
Capacity
(Resolution) (Resolution) (Resolution)
DFG81-2 2 lb (0.02 lb) DFG81-1 KG 1 kg (10 g) DFG81-10 N 10 N (0.1 N) DFG81-5 5 lb (0.05 lb) DFG81-2 KG 2 kg (20 g) DFG81-20 N 20 N (0.2 N) DFG81-10 10 lb (0.1 lb) DFG81-3 KG 3 kg (25 g) DFG81-30 N 30 N (0.25N) DFG81-20 20 lb (0.2 lb) DFG81-5 KG 5 kg (50 g) DFG81-50 N 50 N (0.5 N)
DFG81-10 KG 10 kg (100 g) DFG81-100 N 100 N (1 N) DFG81-30 30 lb (0.25 lb) DFG81-20 KG 20 kg (200 g) DFG81-200 N 200 N (2 N) DFG81-50 50 lb (0.5 lb) DFG81-30 KG 30 kg (250 g) DFG81-300 N 300 N (2.5 N) DFG81-100 100 lb (1 lb) DFG81-50 KG 50 kg (500 g) DFG81-500 N 500 N (5 N)
DFG81 Ranges (Resolution) Accuracy: DFG81 ±0.3% F.S.
DFG82 Ranges (Resolution) Accuracy: DFG82±0.1% F.S.
Pounds Kilograms Newtons
Overload capacity: 165 lbs. for all ranges Stroke: 10 mm F.S.
Overload capacity: 165 lbs. for all ranges Stroke: 10mm F.S.
Model
Capacity
Model
Capacity
Model
Capacity
(Resolution) (Resolution) (resolution)
DFG82-2 2 lb (0.01 lb) DFG82-1 KG 1 kg (5 g) DFG82-10 N 10 N (0.05 N) DFG82-5 5 lb (0.025 lb) DFG82-2 KG 2 kg (10 g) DFG82-20 N 20 N (0.1 N) DFG82-10 10 lb (0.05 lb) DFG82-3 KG 3 kg (20 g) DFG82-30 N 30 N (0.2 N) DFG82-20 20 lb (0.1 lb) DFG82-5 KG 5 kg (25 g) DFG82-50 N 50 N (0.25 N)
DFG82-10 KG 10 kg (50 g) DFG82-100 N 100 N (0.5 N) DFG82-30 30 lb (0.2 lb) DFG82-20 KG 20 kg (100 g) DFG82-200 N 200 N (1 N) DFG82-50 50 lb (0.25 lb) DFG82-30 KG 30 kg (200 g) DFG82-300 N 300 N (2 N) DFG82-100 100 lb (0.5 lb) DFG82-50 KG 50 kg (250 g) DFG82-500 N 500 N (2.5 N)
Dimensions
When installing be sure to keep the depth to 8mm
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR W
ARRANTY RETURNS, please have the
following information available BEFORE contacting OMEGA:
1. P.O. number under which the product was PURCHASED,
2. Model and serial number of the product under warranty, and
3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
1. P.O. number to cover the COST
of the repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
M3515/1099
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
TEMPERATURE
䡺⻬
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
䡺⻬
Wire: Thermocouple, RTD & Thermistor
䡺⻬
Calibrators & Ice Point References
䡺⻬
Recorders, Controllers & Process Monitors
䡺⻬
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
䡺⻬
Transducers & Strain Gauges
䡺⻬
Load Cells & Pressure Gauges
䡺⻬
Displacement Transducers
䡺⻬
Instrumentation & Accessories
FLOW/LEVEL
䡺⻬
Rotameters, Gas Mass Flowmeters & Flow Computers
䡺⻬
Air Velocity Indicators
䡺⻬
Turbine/Paddlewheel Systems
䡺⻬
Totalizers & Batch Controllers
pH/CONDUCTIVITY
䡺⻬
pH Electrodes, Testers & Accessories
䡺⻬
Benchtop/Laboratory Meters
䡺⻬
Controllers, Calibrators, Simulators & Pumps
䡺⻬
Industrial pH & Conductivity Equipment
DATA ACQUISITION
䡺⻬
Data Acquisition & Engineering Software
䡺⻬
Communications-Based Acquisition Systems
䡺⻬
Plug-in Cards for Apple, IBM & Compatibles
䡺⻬
Datalogging Systems
䡺⻬
Recorders, Printers & Plotters
HEATERS
䡺⻬
Heating Cable
䡺⻬
Cartridge & Strip Heaters
䡺⻬
Immersion & Band Heaters
䡺⻬
Flexible Heaters
䡺⻬
Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
䡺⻬
Metering & Control Instrumentation
䡺⻬
Refractometers
䡺⻬
Pumps & Tubing
䡺⻬
Air, Soil & Water Monitors
䡺⻬
Industrial Water & Wastewater Treatment
䡺⻬
pH, Conductivity & Dissolved Oxygen Instruments
Loading...