CL3512A
Digital Thermometer & Calibrator
OMEGAnetSM On-Line Service
http://www.omega.com
USA: ISO 9001 Certified
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
FAX: (203)359-7700
e-mail: info@omega.com
USA and Canada:
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Benelux:
Postbus 8034, 1180 LA Amstelveen,
The Netherlands
Tel: (31) 20 6418405 FAX: (31) 20 6434643
Toll Free in Benelux: 06 0993344
e-mail: nl@omega.com
Czech Republic:
ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Repubic
Tel: 420 (69) 6311627 FAX: 420 (69) 6311114
e-mail: czech@omega.com
France:
9, rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400 FAX: (33)130-699-120
Toll Free in France: 0800-4-06342
e-mail: france@omega.com
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its
products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and
reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected application.
For immediate technical or application assistance:
Servicing North America:
Servicing Europe:
SM
SM
Internet e-mail
info@omega.com
Canada:
976 Bergar
Laval (Quebec) H7L5A1
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: info@omega.com
Mexico and Latin America:
Tel: (95) 800-TC-OMEGA
FAX: (95) 203-359-7807
En Espanol: (203) 359-7803
e-mail: espanol@omega.com
Germany/Austria:
Daimlerstrasse 26, D-75392
Deckenpfronn, Germany
Tel: 49 (07056) 3017 FAX: 49 (07056) 8540
Toll Free in Germany: 0800 82 66342
e-mail: germany@omega.com
United Kingdom: ISO 9002 Certified
One Omega Drive
Riverbend Technology Centre Northbank, Irlam,
Manchester, M44 5EX, England
Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488
e-mail: sales@omega.com.uk
SM
Table of contents
1.0 Introduction
1.1 Safety Information
1.2 Unpacking
2.0 Operation Procedure
2.1 Unit Drawing
2.2 Description of Buttons and Switches
2.3 Read Mode Procedure
2.4 Source Mode Procedure
3.0 Operator Maintenance
4.0 Specifications
5.0 Calibration Procedure
removing contents, save the packing material and carton in
1.0 Introduction
The OMEGA® CL3512A calibrator/thermometer is two meters in one. The
CL3512A simulates type J/K/T/E thermocouple signals. Each signal is
adjustable by using the coarse and fine dials. The CL3512A can also be used
as a dual type J/K/T/E thermocouple input thermometer. Features include a
large 3½ digit display with backlighting and display selections of HOLD, °C/°F,
and0.1/1°.
The source mode of the CL3512A simulates the thermocouple output to check
the operation of a thermocouple meter and make rough calibration
adjustments. A more accurate calibrator would be required for calibration of
thermocouple meters to specify tolerances.
1.1 Safety Information
It is recommended that you read the safety and operation instructions before
using the thermometer.
To avoid electrical shock, do not use this instrument when working
voltages at the measurement surface over 24V AC or DC.
To avoid damage or burns, do not make temperature measurement
Repeated sharp flexing can break the thermocouple leads. To prolong
lead life, avoid sharp bends in the leads, especially near the connector.
WARNING
WARNING
in microwave ovens.
CAUTION
1
1.2 Unpacking
Remove the packing list and verify that all equipment has been received. If
there are any questions about the shipment, please call the OMEGA
Customer Service Department.
Upon receipt of shipment, inspect the container and equipment for any signs
of damage. Immediately report any damage to the shipping agent.
The carrier will not honor any claims unless all shipping
material is saved for their examination. After examining and
the event reshipment is necessary.
The following is supplied in the box:
CL3512A
Rubber boot
2 K beaded wire thermocouples
K calibration cable
9 volt battery
Operator's manual
NOTE
2