Omec OMT2, OMT1 Maintenance Manual

Seite 1 von 10
– Mounting & Maintenance Instructions –
OMT1 & OMT2 Motors
Seite 2 von 10
Inhalt Seite
1 General information 3
2 Delivery 3
3 Mounting 3
4 Coupling 3
4.2.1 Flat belt or V-belt 4
4.2.2 Spur gear transmission 4
5 Electrical connections 4
6 Putting into service 6
7 Maintenance 6
8 Bearing types 8
9 Regrasing interval of bearings 8
10 Disposal 9
11 Motor spare part list / exploded view 10
Seite 3 von 10
1 General information
This manual concerns normal three phase induction motors with an output varying from small to middle size; they are externally cooled, totally enclosed, supplied in a cast iron or aluminium frame and provided with ball bearings or roller bearings, lubricated with grease.
2 Delivery
After receipt, remove the package material, if any, and mind the parts that have been delivered loose.
Check the motor to see whether transport damage has occurred.
You should be able to rotate the shaft easily and smoothly by hand. Compare the details on the nameplate with those of the power network and with the requirements of the motor.
3 Mounting
The motor must be fixed on a stable, clean and flat foundation with good fitting foundation bolts, using washers.
Never mount a motor manufactured for a horizontal mounting on a surface with an angle of inclination of more than 15 degrees without consulting the supplier in advance. Foot & flange motors always have to be mounted in such a way that the drain holes, if any, are situated at the bottom, otherwise you risk that moisture will condensate in the motor and cannot be drained off. To this end you need to remove the drain plugs.
Under no circumstances the entrance of cooling air, drafted by the cooling fan, may be obstructed. This will cause overheating of the motor. Special attention is required where motors will be located in small enclosed rooms.
The ambient cooling temperature must not exceed 40 ºC, unless otherwise agreed upon at the time of ordering.
4 Coupling
4.1 Direct coupling
The motor and driven shafts must be accurately aligned. In case of a flexible coupling, the manufacturers distance between the parts to be coupled must be adhered to, also the degree of misalignment must be within the makers tolerance. We do not recommend using solid couplings.
Loading...