Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan
and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or
negligent use of this equipment. The product shall only be operated by someone over the age of 18, of
sound mind, and not under the inuence of any drugs or alcohol, who has been trained in the correct
operation of this machine, and is wearing authorized, proper safety clothing. Any modication to the
machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of
the machine while in operation.
CHECK PACKAGE UPON ARRIVAL
Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the
external packaging, open carton to ensure all ordered items are within the box, and there is no concealed
damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed),
please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may
initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be
lled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse
for damaged products that were shipped collect or third party.
Before operating any equipment, always read and familiarize yourself with all operation and safety
instructions.
Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save
these instructions for future reference. Also save the original box and packaging for shipping the
equipment if servicing or returning of the machine is required.
Omcan Fabrication et distribution Companie Limité et Food Machinery d’Amerique, dba Omcan et
Omcan Inc. ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne
ait utilisé cet équipement de façon irrégulière. Le produit ne doit être exploité que par quelqu’un de
plus de 18 ans, saine d’esprit, et pas sous l’inuence d’une drogue ou d’acohol, qui a été formé pour
utiliser cette machine correctement, et est vêtu de vêtements de sécurité approprié. Toute modication
de la machine annule toute garantie, et peut causer un préjudice à des personnes utilisant la machine
ou des personnes à proximité de la machine pendant son fonctionnement.
VÉRIFIEZ LE COLIS DÈS RÉCEPTION
Dès réception d’une expédition d’Omcan veuillez inspecter pour dommages externes. Si aucun dommage
n’est visible sur l’emballage externe, ouvrez le carton an de s’assurer que tous les éléments commandés
sont dans la boîte, et il n’y a aucun dommage dissimulé à la machine. Si le colis n’a subi aucune mauvaises
manipulations, de bosses ou de dommages (visible ou cachée), notez-le sur le bond de livraison avant
d’accepter la livraison et contactez Omcan dans les 24 heures qui suivent, pour que nous puissions engager
une réclamation auprès du transporteur. Un rapport détaillé sur l’étendue des dommages causés à la machine
doit être rempli dans un délai de trois jours, à compter de la date de livraison indiquée dans les documents
d’expédition. Omcan n’a aucun droit de recours pour les produits endommagés qui ont été expédiées ou cueilli
par un tiers transporteur.
3
General Information
Avant d’utiliser n’importe quel équipement, toujours lire et vous familiariser avec toutes les opérations
et les consignes de sécurité.
Omcan voudrais vous remercier d’avoir choisi cette machine. Il est primordial de conserver ces
instructions pour une référence ultérieure. Également conservez la boîte originale et l’emballage pour
l’expédition de l’équipement si l’entretien ou le retour de la machine est nécessaire.
Omcan Empresa De Fabricacion Y Distribucion Inc. Y Maquinaria De Alimentos De America, Inc. dba
Omcan y Omcan Inc. no son responsables de ningun daño o perjuicío causado por cualquier persona
inadecuada o el uso descuidado de este equipo. El producto solo podra ser operado por una persona
mayor de 18 años, en su sano juicio y no bajo alguna inuencia de droga o alcohol, y que este ha sido
entrenado en el correcto funcionamiento de esta máquina, y ésta usando ropa apropiada y autorizada.
Cualquier modicación a la máquina anúla la garantía y puede causar daños a las personas usando la
máquina mientras esta en el funcionamiento.
REVISE EL PAQUETE A SU LLEGADA
Tras la recepcion de un envio Omcan favor inspeccionar daños externos. Si no hay daños evidentes en el
empaque exterior, Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la
caja y no encuentre daños ocultos en la máquina. Si el paquete ha sufrido un manejo de poco cuidado, golpes
o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro
de las 24 horas, de modo que podamos iniciar una reclamación con la compañia. Un informe detallado sobre
los daños causados a la máquina debe ser llenado en el plazo de tres días, desde la fecha de entrega que se
muestra en los documentos de envío. Omcan no tiene ningun recurso por productos dañados que se enviaron
a recoger por terceros.
Antes de utilizar cualquier equipo, siempre lea y familiarizarse con todas las instrucciones de
funcionamiento y seguridad.
Omcan le gustaría darle las gracias por la compra de esta máquina. Es de la mayor importancia para
salvar estas instrucciones para futuras consultas. Además, guarda la caja original y el embalaje para el
envío del equipo si servicio técnico o devolución de la máquina que se requiere.
Safety and Warranty
• To minimize shock and re hazards, be sure not to overload the outlet.
• To minimize electric shock and malfunction, do not spray the unit with water.
• To minimize re hazards, do not use ammable spray products near the unit.
• After unplugging the unit, wait at least 6 minutes before re-plugging it. It may cause compressor failure if
plugged in before 6 minutes waiting period.
• Cautions for cleaning:
- Unplug the power cord before cleaning.
4
Safety and Warranty
- Do not unplug-plug the power cord with wet hands.
- Do not use an abrasive cleaners, solvents or polishing agents on plastic parts. Doing so might cause
cracking or discoloring.
• When it is not in use:
- Unplug the power cord.
- Wipe inside with dry cloth, and you may leave the door slightly open to eliminate moisture and odor.
2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR
WARRANTY
Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized
service technician to repair the equipment locally.
Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not
improper use.
Please see https://omcan.com/disclaimer for complete info.
WARNING:
The packaging components are classied as normal solid urban waste and can therefore be disposed of
without difculty.
In any case, for suitable recycling, we suggest disposing of the products separately (differentiated
waste) according to the current norms.
DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!
5
Technical Specications
GLASS DOOR COOLERS
ModelRE-CN-0045-HCRE-CN-0009-HCRE-CN-0014-H
Temperature Range0°C - 5°C / 33°F - 41°F
Max Ambient Temp Rating32°C / 90°F
Horsepower1/4 HP1/5 HP
Electrical110V / 60Hz / 1Ph
Amps4.3A2.88A
RefrigerantR290
Cooling SystemVentilated
Number of Doors21
Number of Shelves84
Shelf Capacity90 lbs. / 40.8 kgs.55.1 lbs. / 25 kgs.77 lbs. / 35 kgs.
Exterior Dimensions
Interior Dimensions
Net Volume1270 L / 45 cu.ft.257.7 L / 9.1 cu.ft.398 L / 14 cu.ft.
Weight441 lbs. / 200 kgs.161 lbs. / 73 kgs.220 lbs. / 99.8 kgs.
Item Number500325003350035
53.25” x 32” x 83.8”
1353 x 813 x 2129mm
50” x 28.5” x 62”
1270 x 724 x 1575mm
21.75” x 21.75” x 63”
552 x 552 x 1600mm
19” x 18” x 46”
483 x 457 x 1168mm
25.6” x 22.8” x 79.4”
650 x 579 x 2017mm
22.8” x 19.8” x 55”
579 x 503 x 1397mm
ModelRE-CN-0023-HCRE-CN-0023-HRE-CN-0052-HC
Temperature Range0°C - 5°C / 33°F - 41°F
Max Ambient Temp Rating32°C / 90°F
Horsepower1/5 HP3/4 HP
Electrical110V / 60Hz / 1Ph
Amps3A10.7A
RefrigerantR290
Cooling SystemVentilated
Number of Doors13
Number of Shelves4512
Shelf Capacity90 lbs. / 41 kgs.
Net Volume648 L / 23 cu.ft.1500.8 L / 53 cu.ft.
ModelFR-CN-0012-HCFR-CN-0790-HCFR-CN-1250-HC
Temperature Range-23°C - -18°C / -10°F - -0°F
Max Ambient Temp Rating32°C / 90°F
Horsepower3/4 HP0.75 HP
Electrical110V / 60Hz / 1Ph
Amps8.8A9.4A
RefrigerantR290
Cooling SystemVentilated
Number of Doors12
Number of Shelves48
Net Volume368 L / 13 cu.ft.648 L / 23 cu.ft.821.2 L / 29 cu.ft.
ModelFR-CN-1250-CFR-CN-0045-HC
Temperature Range-23°C - -18°C / -10°F - -0°F
Max Ambient Temp Rating32°C / 90°F
Horsepower1 3/5 HP1 HP
Electrical110V / 60Hz / 1Ph115V / 60Hz / 1Ph
Amps12A9.2A
RefrigerantR404aR290
Cooling SystemVentilated
Number of Doors2
Number of Shelves810
Shelf Capacity90 lbs. / 41 kg.
Net Volume708 L / 25 cu.ft.1270 L / 45 cu.ft.
• The refrigeration system operates most efciently when installed in an area with cool, dry air circulation.
• There must be at least 6 inches of clearance on both sides and the back of the cabinet.
• Select a location away from the heat and moisture generating equipment such as stoves, ovens, etc.
• Avoid direct sun rays.
• Be sure that the oor where you intend to install that unit is strong and level enough to support the total
weight of the unit and its contents.
• To minimize shock and re hazards, be sure that the unit is properly grounded. For your safety and
protection, all units are equipped with a special three-prong grounding plug on the service cord.
• All units are designed for indoor use. Outdoor use may cause signicant damage to the unit.
Maintenance
• When loading the unit:
- Be careful not to block the air duct located at the back and the fan on the ceiling of the unit with contents.
- Blocking the air ow may cause decrease in performance.
- For the best performance, maintain at least 4 inches of clearance between the contents and the air duct.
• Set the shelves that come with the unit to t your needs.
• Temperature controller:
- The controller is located at the right, front corner of the ceiling, or on the front bottom panel.
- To adjust temperature please refer to the manual of temperature controller.
• Do not leave the unit door open for long period of time. For the most efcient operation, close the door
immediately after the use.
ICE ACCUMULATION MAY OCCUR IN FREEZERS
• Try to reduce the amount of time the freezer doors remain open to prevent ice accumulation.
• Keep door seals clean to prevent air leakage.
• Scrape off any ice accumulated or try manual defrost mode.
8
Troubleshooting
SYMPTOMSPOSSIBLE CAUSE
Compressor will not startCheck if the power cord has been plugged in.
Check for blown fuse.
Poor PerformanceMove the unit from direct sun light, and avoid
installing heating devices near the unit.
Install the unit in a well ventilated place with minimum
of 6” clearance in the back.
Check the condenser, and clean if heavy dust is
collected.
Check to see if contents are blocking the air duct.
Check to see if refrigerant charge is low.
Make sure the door is completely closed.
No Interior LightTurn off the light switch and turn it on again.
Make sure the light is correctly inserted into the
sockets.
Check the light, and replace it if blown.
Unit NoisyMake sure to install the unit on level surface.
Make sure to maintain the minimum clearance of 6”
from the wall.
Check for the loose parts or mounting.
Make sure the tubing is free from any contact to avoid
tubing rattle.
Condensation on Cabinet and/or FloorReduce the relatively humidity in the area where the
unit is installed.
Gasket on door or head section is not sealing
properly. Repair or replace gasket as necessary.
9
Controller Instructions
Digital controller model: PJEZ for cooler
Display and functions
During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient
probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation
of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the
functions(see Table 2).
LED’s and Associated Functions (Table 1)
IconFunctionNormal OperationStart Up
ONOFFBlink
CompressorOnOffRequestON
FanOnOffRequestON
DefrostOnOffRequestON
AuxOutput OnOutput Off-ON
AlarmAllNo Alarm-ON
ClockRTC tted and enabled, at
least 1 time band set
RTC not tted or disabled, not
even 1 time band set
-ON if RTC
tted
10
Controller Instructions
Table of Functions activated by the buttons - Models S, X, Y, C (Table 2)
ButtonNormal OperationStart Up
Pressing the Button AlonePressed Together
Up
ON/OFF
Down
Defrost
Set Mute- 1 sec.: display/set the set
Setting the set point (desired temperature)
More than 3 sec: toggle ON/
OFF
More than 3 sec: start/stop
defrost
point.
- more than 3 secs.: access
parameter setting menu
(enter password )
- mute audible alarm
(buzzer)
Start/Stop
continuous cycle
-For 1 sec.
-
Pressed
together
Start parameter
reset procedure
For 1 sec.
display
rmware
vers. code
RESET current EZY set
• press SET for 1 sec, the set value will start ashing after a few moments;
• increase or decrease the value using UP or DOWN;
• press SET to conrm the new value.
Switching the device ON/OFF
Press UP for more than 3 sec. The control and defrost algorithms are now disabled and the Instrument
displays the message “OFF” alternating with the temperature read by the set probe.
Manual defrost
Press for DOWN more than 3 sec (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3 sec.
Access and setting type F (frequent) and type C (conguration) parameters.
1. Press SET for 3 sec (the display will show “PS”).
2. • To access the type F and C parameter menu, enter the password “22” using UP/DOWN, press SET to
conrm.
• To access the F parameter menu only, press SET (without entering the password).
3. Scroll inside the parameter menu using UP/DOWN.
11
Controller Instructions
• To display/set the values of the parameter displayed, press SET, then UP/DOWN and nally SET to
conrm the changes (returning to the parameter menu).
To save all the new values and exit the parameter menu, press SET for 3 s.
To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s.
Digital controller model: IR33 for freezer
Signals on the display
The blinking status indicates a request for activation that cannot be implemented until the end of the
Corresponding delay times.
IconFunctionONOFFBlinkStartup
Compressor Compressor onCompressor offRequest
FanFan onFan offRequest
DefrostDefrost in progressDefrost not required Request
AuxAuxiliary Output AUX
active
AlarmDelayed external
alarm (before the
expiry of the time ‘A7’)
ClockAt least one timed
defrost has been set
Auxiliary Output
AUX not active
No alarm presentAlarms in normal operation
No timed defrost is
present
Anti-sweat heater function
active
(eg. high/low temp.) or
alarm from ext. digital input
immediate or delayed
Clock alarmOn if Real-
Time Clock
present
12
Controller Instructions
LightAuxiliary output light
active
ServiceNo malfunctionMalfunction (eg. EEPROM
HACCPHACCP functionHACCP function
Continuous
Cycle
EnabledNot enabledRequest
Auxiliary output light
not active
enabled
Anti-sweat heater function
active
error or probe fault)
HACCP alarm (HA and/or
HF) not enabled
Setting the set point (desired temperature value)
To display or set the set point, proceed as follow:
1. press the “Set” button for more than 1 second to display the set point;
2. increase or decrease the value of the set point, using the “ ” and “ ” respectively, until reaching the
desired value;
3. press the “Set” button again to conrm the new value,
Alarms with manual reset
The alarms with manual reset can be reset by pressing the “ ” and “ ” for more than 5 sec.
Manual defrost
As well as the automatic defrost function, a manual defrost can be enabled, if the temperature conditions allow,
by pressing the “ ” button for more than 5 sec.
Continuous cycle
Pressing the buttons “ ” and “ ” simultaneously for more than 5 seconds enables the continuous cycle
function. During operation in continuous cycle, the compressor continues to operate for the time “cc” and
it stops when it reaches the “cc” time out or the minimum temperature has been reached(AL = minimum
temperature alarm threshold). Continuous cycle setting: “cc” parameter (continuous cycle duration): “cc”=0
never active; “c6” parameter (by passing the alarm after the continuous cycle):”cc” = 0 never active; it avoid or
delays the low temperature alarm after the continuous cycle.
Accessing the conguration parameter (type C)
1. Pressing the “ ” and “Set” buttons at the same time for more than 5 sec, the display will show
“00”(password prompt).
2. Use the “ ” or “ ” buttons to display the number “22” (parameter access password).
3. Conrm by pressing “Set”.
4. The display will show the rst modiable “C” parameter.
13
Controller Instructions
Accessing the conguration parameter (type F)
1. Hold the “ ” button for more than 5 s (if there are active alarms, rst mute the buzzer), the display will
show the rst modiable “F” parameter.
Modifying the parameters
After having displayed the parameter, either type “C” or type “F”, proceed as follows:
1. Use the “ ” or “ ” buttons to scroll the parameters, until reaching the parameter to be modied; when
scrolling the parameters, an icon is shown on the display that represents the category of the parameter.
2. Alternatively, press the “ ” button to display a menu that can be used to quickly access the family of
parameters to be modied.
3. Scrolling the menu using the “ ” and “ ” buttons displays the codes of the various categories of
parameter, accompanied by the corresponding icon on the display(if present).
4. Once having reached the desired category, press “Set” to go directly to the rst parameter in the chosen
category(if no parameter is visible, pressing the “Set” button will have no effect).
5. At this stage, modify the parameters or return to the “Category” menu, using the “ ” button.
6. Press “Set” to display the value associated with the parameter.
7. Increase or decrease the value using the “ ” or “ ” buttons respectively.
8. Press “Set” to temporarily save the new value and return to the display of the parameter.
9. Repeat the operation from point 1 or point 2.
10. If the parameter has sub-parameters, press “Set” to display the rst sub-parameter.
11. Press the “ ” or “ ” button to display all the sub-parameters.
12. Press “Set” to display the associated value.
13. Increase or decrease the value using the “ ” or “ ” button respectively.
14. Press “Set” to temporarily save the new value and return to the display of the sub-parameter code.
15. Press “ ” to return to the display of the parent parameter.
Saving the new values assigned to the parameters
To denitely save the new values of the modied parameters, press the “ ” button for more than 5 seconds,
thus exiting the parameter setting procedure. All the modication made to the parameters temporarily saved in
the RAM, can be cancelled and “normal operation” resumed by not pressing any button for 60 seconds, thus
allowing the parameter setting session to expire due to timeout if the Instrument is switched off before pressing
the “ ” button, all the modications made to the parameters and temporarily saved will be lost.
Mechanical Controller Instructions
OFF: shut the compressor off
Temperature range from 7 (coldest) to 1 (warmest).
CAUTION: Setting the temperature control to the coldest setting may cause the
evaporator coil to freeze and ice up. This will eventually result in a warmer cabinet
temperature.
14