Our products are manufactured under ISO-9001 Quality Assurance System, approved by CSQ certified under no.9190.OMC2 - FIRST ISSUE 1994/08/04
OMC s.r.l. Via G. Galilei, 18 - 20060 - Cassina de Pecchi (MI) - ITALY - www.omcsrl.com - Tel.: (+39) 02.95.28.468
Installaon, Operaon and Maintenance Manual TD10/…‐en Rev.03/2018
1.0 SAFETY INFORMATION
The safe operation of this product is ensured only if it is installed, commissioned, used and maintained in an
appropriate way by qualified personnel in compliance with the operating instructions.
1.01 INTENDED USE
Verify that the actuator is suitable for the intended use and application by controlling:
- that the material of which the valve is made up of is compatible with the process fluid;
- that the valve is suitable to the pressures and temperatures of the process fluid;
- to have arranged a suitable safety device which prevents, in case of valve malfunctioning, any hazardous
overpressures or overtemperatures.
The OMC valves are not intended to withstand any external stresses which can be induced by the systems in
which they are inserted. The installer must take account of these stresses and take the appropriate measures.
1.02 ACCESS
Ensure a safe access and, if required, a safe working platform (with a suitable protection) before operating on the
product. Arrange the suitable lifting means, if required.
1.03 LIGHTING
Ensure a lighting which is suitable to the required type of work.
1.04 HAZARDOUS FLUIDS IN THE PIPE
Take account of the content of the pipe or anything it may have previously contained. Be careful to: flammable
materials, substances hazardous for the health, temperature extremes.
1.05 ENVIRONMENTAL SITUATIONS
ENGLISH
Take account of: areas at risk of explosion, lack of oxygen (such as tanks, wells, etc.…), hazardous gases,
temperature limits, high or low temperature surfaces, risk of fire (for example during welding operations),
excessive noise, moving machines.
1.06 TEMPERATURE
Wait until the temperature normalizes after the interception to prevent any risks of burn or freezing.
1.07 SYSTEM
Take account of the possible effects on the whole expected working system.
May the intended measure put the other parts of the system or the personnel at risk?
Make sure that the shut-off valves are gradually activated in order to prevent any abrupt variations to the system.
1.08 PRESSURIZED SYSTEMS
Make sure that the pressure is isolated and discharged to the atmospheric pressure in safe conditions. Take
account of a double insulation (double block and vent) and the blocking or the labelling of the closed valves. Do
not consider the system depressurized even if the pressure gauge indicates zero pressure.
During the operation the valve is pressurized. Before performing any maintenance operation or action on
the flanges and closing caps, make sure that the line is depressurized (0 bar) and at ambient temperature.
Our products are manufactured under ISO-9001 Quality Assurance System, approved by CSQ certified under no.9190.OMC2 - FIRST ISSUE 1994/08/04
OMC s.r.l. Via G. Galilei, 18 - 20060 - Cassina de Pecchi (MI) - ITALY - www.omcsrl.com - Tel.: (+39) 02.95.28.468
Page 3
Installaon, Operaon and Maintenance Manual TD10/…‐en Rev.03/2018
1.09 TOOLS AND CONSUMABLE PARTS
Before starting the work, make sure to have at your disposal all the tools required to perform it, do not make use
of inappropriate tools. Use only OMC original spare parts.
ENGLISH
1.10 PROTECTION CLOTHES
Take account of whether you and/or others need some clothes against the hazards, such as chemical products,
temperatures, radiations, noise, fall of objects, risks for eyes and face.
1.11 QUALIFICATION OF THE OPERATORS IN CHARGE OF THE WORKS
All works must be performed and supervised by some skilled, trained and competent personnel.
1.12 HANDLING
Use suitable lifting means for the handling of the products by assessing all the risks concerning the lifting, the
environment load, the individual and the circumstances of the work which is about to be performed.
CORRECT
CORRECT WRONG
1.13 FREEZING
Protect the products against frozen in environments with temperatures lower than the freezing point of the
process fluid.
1.14 OTHER RISKS
During the operation, the external surface of the product can be at temperatures which are hazardous to touch.
Take account of this risk.
1.15 DISPOSAL
For the disposal respect the legislation in force in the State/Country/Nation where the product should be disposed
of.
1.16 RISK OF CORROSION AND/OR EROSION
Periodically verify any phenomena of internal and/or external corrosion and/or erosion as they may
significantly damage the pressurized parts by locally reducing the thickness and as a consequence the
safety degree.
Our products are manufactured under ISO-9001 Quality Assurance System, approved by CSQ certified under no.9190.OMC2 - FIRST ISSUE 1994/08/04
Page 4
OMC s.r.l. Via G. Galilei, 18 - 20060 - Cassina de Pecchi (MI) - ITALY - www.omcsrl.com - Tel.: (+39) 02.95.28.468
Installaon, Operaon and Maintenance Manual TD10/…‐en Rev.03/2018
2.0 INSTALLATION
All works must be performed and supervised by skilled, trained and competent personnel.
The fusion of the OMC valves’ body highlights the flow direction, the maximum operating pressure and the
material.
Before installing the valve, make sure that the pipe which channels the process fluid is clean, by performing, if
required, an energetic blowing with steam or compressed air.
The installation of the filter upstream the valve will prevent the entrance of any dirt in the plug.
To perform periodical maintenance operations of the valves installed on continuous-operation systems, it is
recommended to install three shut-off valves, located upstream and downstream of the three-way valve. The three
shut-off valves must have the same internal diameter of the control valve. During the installation of the valve,
make sure that the flow in the pipe goes in the same direction as indicated by the arrow on the valve body.
The assembling position of the valve does not limit its operation, but it is recommended to assemble the valve
with the actuator pointed upward as other positions might allow the accumulation of any impurities which are
contained in the fluid thus damaging the valve itself.
2.01 ASSEMBLY OF THE VALVE ON THE PIPE
To ensure a uniform load and a uniform alignment, the flange bolts must be gradually tightened in criss-cross
sequence, as indicated in Pic.2
Prevent any excessive tightening. Use the recommended tightening torques. Prevent any pipe
misalignment. Choose the flange gaskets according to the operating conditions.
ATTENTION!!! For valves with braze-on connections, the welding operation must be performed
only by qualified personnel and, in order to prevent any damages to the valves, keep the valve
body cold during the above-mentioned operation.
Our products are manufactured under ISO-9001 Quality Assurance System, approved by CSQ certified under no.9190.OMC2 - FIRST ISSUE 1994/08/04
OMC s.r.l. Via G. Galilei, 18 - 20060 - Cassina de Pecchi (MI) - ITALY - www.omcsrl.com - Tel.: (+39) 02.95.28.468
Pic. 2 Tightening sequence
Page 5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.