This instruction manual contains essential information on how to use this Olympus product safely and effectively.
Before using this product, thoroughly review this instruction manual. Use the product as instructed.
Keep this instruction manual in a safe, accessible location.
Olympus NDT, 48 Woerd Avenue, Waltham, MA 02453, USA
This document was prepared with particular attention to usage to ensure the
accuracy of the information contained therein, and corresponds to the version of
the product manufactured prior to the date appearing on the title page. There
could, however, be some differences between the manual and the product if the
product was modified thereafter.
The information contained in this document is subject to change without notice.
Part number: DMTA-20015-01EN [U8778402]
Rev. J
January 2014
Printed in Canada
All brands are trademarks or registered trademarks of their respective owners and
third party entities.
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Table of Contents
List of Abbreviations ....................................................................................... xi
Labels and Symbols ........................................................................................... 1
Important Information — Please Read Before Use ..................................... 7
Intended Use .......................................................................................................................... 7
O.3 Data Specifications .................................................................................................. 196
List of Figures ................................................................................................. 199
List of Tables ................................................................................................... 201
Index ................................................................................................................. 205
Table of Contents ix
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Table of Contents
x
List of Abbreviations
DCdirect current
ECAEddy current array
ECTEddy current testing
EFUPenvironment-friendly use period
FSfull speed
HShigh speed
IATAInternational Air Transport Association
ICAOInternational Civil Aviation Organization
IMOInternational Maritime Organization
NDTnondestructive testing
PAphased array
RHrelative humidity
SDHCSecure Digital High Capacity
TFTthin film transistor
USDOTUS Department of Transportation
UTultrasonic testing
WEEEwaste electrical and electronic equipment
DMTA-20015-01EN [U8778402], Rev. J, January 2014
List of Abbreviations xi
DMTA-20015-01EN [U8778402], Rev. J, January 2014
List of Abbreviations
xii
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Location of rating label
(see Table 1 on page 3)
Membrane
vent label
Identification
label
Labels and Symbols
Safety-related labels and symbols are attached to the instrument at the locations
shown in Figure i-1 on page 1, Figure i-2 on page 2, and Figure i-3 on page 2. If any or
all of the labels or symbols are missing or illegible, please contact Olympus.
Figure i-1 The OmniScan MX2
Labels and Symbols
1
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Location of rating label
(see Table 1 on page 3)
Module
identification
label
Figure i-2 The OmniScan MX
Labels and Symbols
2
Figure i-3 Module identification label
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Table 1 OmniScan MX2 and the OmniScan MX rating labels
OmniScan MX2
rating label
a
:
OmniScan MX
rating label:
Contains:
The C-Tick label indicates that the product complies with the
applicable standard, and establishes a traceable link between
the equipment and the manufacturer, importer, or agent
responsible for compliance, and for placing it on the
Australian market.
The WEEE symbol indicates that the product must not be
disposed of as unsorted municipal waste, but should be
collected separately.
The CE marking is a declaration that this product conforms to
all the applicable directives of the European Community. See
the Declaration of Conformity for details (contact your local
Olympus representative for more information).
Labels and Symbols
3
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Table 1 OmniScan MX2 and the OmniScan MX rating labels (continued)
The China RoHS mark indicates the product’s EnvironmentFriendly Use Period (EFUP). The EFUP is defined as the
number of years for which listed controlled substances will
not leak or chemically deteriorate while in the product. The
EFUP for the OmniScan MX2 has been determined to be
15 years. Note: The Environment-Friendly Use Period (EFUP)
is not meant to be interpreted as the period assuring
functionality and product performance.
The direct current symbol.
The DC adaptor polarity symbol.
M/NThe model number (on the OmniScan MX rating plate label).
S/NThe serial number (on the OmniScan MX rating plate label).
CALIB. DATEIndicates the date on which the unit was calibrated.
CALIB. DUEIndicates the date on which the next calibration must be
performed.
PAR/BYThe initials of the person who calibrated the instrument.
M
ANUFACTURING
DATE
(OmniScan MX2:
former label)
Labels and Symbols
4
The manufacturing number is a nine (9) digit number in the
following format:
yyzzzzzmm
where:
yy Production year
zzzzz Unit number manufactured that month
mm Production month
For example, the 110003401 manufacturing number indicates
that the 34
th
unit (00034) was produced on January 2011.
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Table 1 OmniScan MX2 and the OmniScan MX rating labels (continued)
Mfg. Date
The manufacturing date in the following format:
(OmniScan MX2:
new label)
where:
yyyy Production year
mm Production month
dd Production day
a. The OmniScan MX2 rating label may vary.
Table 2 Content of the OmniScan MX2 identification label
Identification
label:
Contains:
M/NModel number
S/NSerial number
Table 3 Content of a module identification label
yyyy-mm-dd
Identification
a
label
:
Contains:
M/NModel number
MFGDATEManufacturing date
S/NSerial number
a. Refer to Table 1 on page 3 for symbol signification and to Figure i-3 on page 2 for label
location.
Labels and Symbols
5
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Membrane
vent label
The membrane vent (see Figure i-4 on page 6) is used to counterbalance the internal
and external pressure, and to maintain the instrument’s watertight integrity. Do not
puncture the membrane vent. Puncturing of the membrane vent will result in the
instrument’s failure to comply with the IP rating.
Labels and Symbols
6
Figure i-4 The OmniScan MX2 membrane vent
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Important Information — Please Read Before Use
Intended Use
The OmniScan MX and OmniScan MX2 are designed to perform nondestructive
inspections on industrial and commercial materials.
Do not use the OmniScan MX and OmniScan MX2 for any purpose other than their
intended use. They must never be used to inspect or examine human or animal body
parts.
Instruction Manual
This instruction manual contains essential information on how to use these Olympus
products safely and effectively. Before using these products, thoroughly review this
instruction manual. Use the products as instructed.
Keep this instruction manual in a safe, accessible location.
Important Information — Please Read Before Use
7
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Some of the details of components illustrated in this manual may differ from the
components installed on your instrument. However, the operating principles remain
the same.
Instrument Compatibility
Refer to Appendix A on page 123 to confirm that the OmniScan MX or
OmniScan MX2 are compatible with the ancillary equipment being used.
Always use equipment and accessories that meet Olympus specifications. Using
incompatible equipment could cause malfunction and/or equipment damage, or
injury.
Repair and Modification
The OmniScan MX and OmniScan MX2 do not contain any user-serviceable parts.
Opening an instrument might void the warranty.
In order to prevent human injury and/or equipment damage, do not disassemble,
modify, or attempt to repair the instrument.
Important Information — Please Read Before Use
8
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Safety Symbols
The following safety symbols might appear on the instrument and in the instruction
manual:
General warning symbol:
This symbol is used to alert the user to potential hazards. All safety messages that
follow this symbol shall be obeyed to avoid possible harm or material damage.
High voltage warning symbol:
This symbol is used to alert the user to potential electric shock hazards greater
than 1000 volts. All safety messages that follow this symbol shall be obeyed to
avoid possible harm.
Safety Signal Words
The following safety symbols might appear in the documentation of the instrument:
The DANGER signal word indicates an imminently hazardous situation. It calls
attention to a procedure, practice, or the like, which, if not correctly performed or
adhered to, could result in death or serious personal injury. Do not proceed beyond a
DANGER signal word until the indicated conditions are fully understood and met.
The WARNING signal word indicates a potentially hazardous situation. It calls
attention to a procedure, practice, or the like, which, if not correctly performed or
adhered to, could result in death or serious personal injury. Do not proceed beyond a
WARNING signal word until the indicated conditions are fully understood and met.
Important Information — Please Read Before Use
9
DMTA-20015-01EN [U8778402], Rev. J, January 2014
The CAUTION signal word indicates a potentially hazardous situation. It calls
attention to an operating procedure, practice, or the like, which, if not correctly
performed or adhered to, could result in minor or moderate personal injury, material
damage, particularly to the product, destruction of part or all of the product, or loss of
data. Do not proceed beyond a CAUTION signal word until the indicated conditions
are fully understood and met.
Note Signal Words
The following symbols could appear in the documentation of the instrument:
The IMPORTANT signal word calls attention to a note that provides important
information, or information essential to the completion of a task.
The NOTE signal word calls attention to an operating procedure, practice, or the like,
which requires special attention. A note also denotes related parenthetical
information that is useful, but not imperative.
The TIP signal word calls attention to a type of note that helps you apply the
techniques and procedures described in the manual to your specific needs, or
provides hints on how to effectively use the capabilities of the product.
Safety
Before turning on the instrument, verify that the correct safety precautions have been
taken (see the following warnings). In addition, note the external markings on the
instrument, which are described under “Safety Symbols”.
Important Information — Please Read Before Use
10
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Warnings
General Warnings
•Carefully read the instructions contained in this instruction manual prior to
turning on the instrument.
•Keep this instruction manual in a safe place for further reference.
•Follow the installation and operation procedures.
•It is imperative to respect the safety warnings on the instrument and in this
operation manual.
•If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment could be impaired.
•Do not install substitute parts or perform any unauthorized modification to the
instrument.
•Service instructions, when applicable, are for trained service personnel. To avoid
the risk of electric shock, do not perform any work on the instrument unless
qualified to do so. For any problem or question regarding this instrument, contact
Olympus or an authorized Olympus representative.
•Do not touch the connectors directly by hand. Otherwise, a malfunction or electric
shock may result.
•Do not allow metallic or foreign objects to enter the device through connectors or
any other openings. Otherwise, a malfunction or electric shock may result.
Electrical Warnings
•Before turning on the instrument, you must connect the protective earth terminal
of the instrument to the protective conductor (mains) of the power cord. The
mains plug shall only be inserted into a socket outlet provided with a protective
earth contact. Never negate the protective action by using an extension cord
(power cable) without a protective conductor (grounding).
Important Information — Please Read Before Use 11
DMTA-20015-01EN [U8778402], Rev. J, January 2014
•Only use fuses with the required rated current, voltage, and specified type
(normal-blow, slow-blow, quick-acting, etc.). Do not use repaired fuses or shortcircuited fuse holders. Doing so could cause electric shock or create a fire hazard.
•If there is any possibility that the ground protection could be impaired, you must
make the instrument inoperative and secure it against any unintended operation.
•The instrument must only be connected to a power source corresponding to the
type indicated on the rating label.
Battery Precautions
•Before disposing of a battery, check your local laws, rules, and regulations, and
follow them accordingly.
•Transportation of lithium-ion batteries are regulated by the United Nations under
the United Nations Recommendations on the Transport of Dangerous Goods. It is
expected that governments, intergovernmental organizations, and other
international organizations shall conform to the principles laid down in these
regulations, thus contributing to worldwide harmonization in this field. These
international organizations include the International Civil Aviation Organization
(ICAO), the International Air Transport Association (IATA), the International
Maritime Organization (IMO), the US Department of Transportation (USDOT),
and others. Please contact the transporter and confirm current regulations before
transportation of lithium-ion batteries.
•For California (USA) only:
The CR battery contains perchlorate material, and special handling may be
required. Refer to http://www.dtsc.ca.gov/hazardouswaste/perchlorate.
•Do not open, crush, or perforate batteries; doing so could cause injury.
•Do not incinerate batteries. Keep batteries away from fire and other sources of
extreme heat. Exposing batteries to extreme heat (over 80 °C) could result in an
explosion or personal injury.
•Do not drop, hit, or otherwise abuse a battery, as doing so could expose the cell
contents, which are corrosive and explosive.
•Do not short-circuit the battery terminals. A short circuit could cause injury and
severe damage to a battery making it unusable.
Important Information — Please Read Before Use
12
DMTA-20015-01EN [U8778402], Rev. J, January 2014
•Do not expose a battery to moisture or rain; doing so could cause an electric
shock.
•Only use the OmniScan MX or OmniScan MX2 unit or an external charger
approved by Olympus to charge the batteries.
•Only use batteries supplied by Olympus.
•Do not store batteries that have less than 40 % remaining charge. Recharge
batteries to between 40 % and 80 % capacity before storing them.
•During storage, keep the battery charge between 40 % and 80 %.
•Do not leave batteries in the OmniScan MX or OmniScan MX2 unit during
instrument storage.
Equipment Disposal
Before disposing of the OmniScan MX or OmniScan MX2, check your local laws,
rules, and regulations, and follow them accordingly.
CE (European Community)
WEEE Directive
This device complies with the requirements of both directive
2004/108/EC concerning electromagnetic compatibility and directive
2006/95/EC concerning low voltage. The CE marking indicates
compliance with the above directives.
In accordance with European Directive 2002/96/EC on Waste Electrical
and Electronic Equipment (WEEE), this symbol indicates that the
product must not be disposed of as unsorted municipal waste, but
should be collected separately. Refer to your local Olympus distributor
for return and/or collection systems available in your country.
Important Information — Please Read Before Use 13
DMTA-20015-01EN [U8778402], Rev. J, January 2014
China RoHS
China RoHS is the term used by industry generally to describe legislation
implemented by the Ministry of Information Industry (MII) in the People’s Republic
of China for the control of pollution by electronic information products (EIP).
The China RoHS mark indicates the product’s EnvironmentFriendly Use Period (EFUP). The EFUP is defined as the number of
years for which listed controlled substances will not leak or
chemically deteriorate while in the product. The EFUP for the
OmniScan MX2 has been determined to be 15 years.
Note: The Environment-Friendly Use Period (EFUP) is not meant
to be interpreted as the period assuring functionality and product
performance.
EMC Directive Compliance
This equipment generates and uses radio-frequency energy and, if not installed and
used properly (that is, in strict accordance with the manufacturer’s instructions), may
cause interference. The OmniScan MX and OmniScan MX2 have been tested and
found to comply with the limits for an industrial device in accordance with the
specifications of the EMC directive.
FCC (USA) Compliance
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, might cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own
expense.
Important Information — Please Read Before Use
14
DMTA-20015-01EN [U8778402], Rev. J, January 2014
ICES-001 (Canada) Compliance
This Class A digital apparatus complies with Canadian ICES-001.
Cet appareil numérique de la classe A est conforme à la norme NMB-001 du Canada.
Warranty Information
Olympus guarantees your Olympus product to be free from defects in materials and
workmanship for a specific period, and in accordance with conditions specified in the
Olympus NDT Terms and Conditions available at http://www.olympusims.com/en/terms/.
The Olympus warranty only covers equipment that has been used in a proper
manner, as described in this instruction manual, and that has not been subjected to
excessive abuse, attempted unauthorized repair, or modification.
Inspect materials thoroughly on receipt for evidence of external or internal damage
that might have occurred during shipment. Immediately notify the carrier making the
delivery of any damage, because the carrier is normally liable for damage during
shipment. Retain packing materials, waybills, and other shipping documentation
needed in order to file a damage claim. After notifying the carrier, contact Olympus
for assistance with the damage claim and equipment replacement, if necessary.
This instruction manual explains the proper operation of your Olympus product. The
information contained herein is intended solely as a teaching aid, and shall not be
used in any particular application without independent testing and/or verification by
the operator or the supervisor. Such independent verification of procedures becomes
increasingly important as the criticality of the application increases. For this reason,
Olympus makes no warranty, expressed or implied, that the techniques, examples, or
procedures described herein are consistent with industry standards, nor that they
meet the requirements of any particular application.
Olympus reserves the right to modify any product without incurring the
responsibility for modifying previously manufactured products.
Important Information — Please Read Before Use 15
DMTA-20015-01EN [U8778402], Rev. J, January 2014
Technical Support
Olympus is firmly committed to providing the highest level of customer service and
product support. If you experience any difficulties when using our product, or if it
fails to operate as described in the documentation, first consult the user’s manual, and
then, if you are still in need of assistance, contact our After-Sales Service. To locate the
nearest service center, visit the Service Centers page at: http://www.olympusims.com.
Important Information — Please Read Before Use
16
OmniScan MX2
Model no. OMNI-MX2
Loading...
+ 198 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.