![](/html/fc/fc29/fc2994e2269fe3f6f206ba8f9700fb34eb3df0cff74ee9d4dad74d22a9ae6300/bg1.png)
Tools:
OLYMPIA FAUCETS, INC.
Interchange City Distribution Center #20
1277 Heil Quaker Boulevard
La Vergne, TN 37086
(888) 772-7701
www.olympiafaucets.com
Adjustable Wrench Plumbers Putty Teon Tape Rags
Model Number: L-7220, L-7221, L-7222, L-7290, L-7291
L-7292, L-7280, L-7282, L-7250, L-7251, L-7251G
Warnings and Notes:
Check with local plumbing code requirements before installation.
This product should be installed by a local listed plumber.
Do not use plumbers putty on threads.
Installation Steps:
Two Handle Lavatory Faucet
Pop-up Drain Installation:
(1) Shut off water supplies. Remove old faucet.
Clean mounting surface in preparation for new
faucet.
INSTALLATION
(1) Remove pop-up ange from body
(2) Place the faucet in position on the sink.
Apply plumbers putty under the base gasket.
Install washer on shanks and tighten with
locknut.
(3a) when using ball-nose exible supplies
to connect faucet to water supply valves, slip
coupling nut onto exible supply. Ball-nose
coupling will go partially into shank. Tighten
coupling nut (DO NOT OVERTIGHTEN).
Install opposite end according to
manufacturer’s instruction for both tubes.
(3b) when using stainless steel braided
faucet supply hose; this faucet requires one
end of the supply hose to have a ½” female
IPS connection. The other end of this supply
hose must match the thread on the water
supply valve under your sink. Once you’ve
identied the required size, carefully follow
the manufacturer’s installation instructions for
each hose.
(4) Important: After installation is complete,
remove aerator. Turn water supplies on and
allow both hot and cold water to run at least
one minute each. While water is running,
check for leaks. Turn off water and replace
aerator.
(2) Place a ring of putty on the bottom of
ange.
(3) Insert pop-up ange through drain hole
and attach fIange to body. Ensure the pop-up
outlet faces towards the back of the slnk
Tíghten the locknut securely with a wrench Do
not overtighten.
(4) Remove the excess putty. Connect the
trap (check manufacturer’s instructions for
ínstallation)
(5) Remove pivot rod nut from pop-up body,
ensure the washers is in place, insert pivot
rod, tighten pivot rod nut back to pop-up body.
![](/html/fc/fc29/fc2994e2269fe3f6f206ba8f9700fb34eb3df0cff74ee9d4dad74d22a9ae6300/bg2.png)
(6) Push pivot rod down, insert drain plug
carefully. Test to ensure drain plug works
properly.
Exploded Drawing:
(7) Connect lift rod strap to pivot rod by using
clip. Tighten the thumbscrew to connect lift rod
strap to pop-up lift rod.
ITEM # DESCRIPTION
1 OP-490012C,H Acrylic Handle Button Cold, Hot
2 OP-490014 Screw
3 OP-490013C,H Mini Blade Handle Button Cold, Hot
4 OP-490042 Handle Hub Screw
5 OP-490015 Handle Screw
6 OP-490016C,H Wrist Blade Handle Button Cold,
Hot
1
A1
3
2
2
ITEM # DESCRIPTION
A1 OP-190003C,H Acrylic Handle Cold,Hot
A2 OP-190004C,H Mini Blade Handle Cold, Hot
A3 OP-190006C,H Handle Hub
A4 OP-490017 Chrome Insert
A5 OP-490018 Acrylic White Insert
A6 OP-190005C,H Wrist Blade Handle Cold, Hot
B OP-490040 Bonnet Nut
C OP-390004
OP-390005
Stem Unit-Brass Post
Stem Unit-Plastic Post
D OP-490041 Spring and Seats
E OP-490035 1.5 GPM Aerator
F OP-590003 Mounting Locknuts & Washers
G OP-590001 Supply Nuts
H OP-630004
OP-630002
4
A3
A2
50/50 Pop-Up Drain Assembly
Brass Pop-Up Drain Assembly
5
6
A5
A6
H
E
B
C
D
F
G
A4
For more care information or trouble shooting
inquiries about your Olympia product, Please call:
OLYMPIA FAUCETS, INC. (888) 772-7701
8AM - 8PM EST (5AM to 5PM PST)
www.olympiafaucets.com