● Wireless connection between thermostat and commands of Relay.
● Connection with WiFi.
Controlled from the smartphone.
RF signal strength indicator.
● 3 operation modes: manual, daily and weekly.
Easy programm entry.
Multiply indication screen with backlight.
Clock, Calender.
Keypad lock
Selection of upper and lower limits for manual temperature selection.
Boiler operation (BS-851/Τ) with selectable time.
Easy connection - adjustment.
1
2
3
4
5
6
7
8
9
940851000_09_001
ESC
MENU
ENTER
1
2
3
4
5
20
19
18
17
16
15
21
23
24
26
27
28
25
22
7
8 9 10
12 1411
6
13
The key is like this
on the BS-850/T.
BS-850/T - BS-851/T
BS-850/R - BS-851/R
Only for BS-851/R
CONTROL AND INDICATIOR DESCRIPTION
Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator
= When the selection is less than the
actual temperature. = When the selection + the differential is
more than the actual temperature. = When the temperature is between the
selection and the selection the
+
differential.
BS-850/KIT, BS-851/KIT
BS-850/KIT, BS-851/KIT
Wi
Thank you for your trust in our products
Olympia Electronics - European manufacturer
WIR E L ESS PR O GRAM M A BLE Wi F i C HRON O - T HERM O S TAT
WIT H H E ATIN G F UNCT I O N - BATT E R Y OPER A TED WI T H B OILE R O U TPUT
WIR E L ESS PR O GRAM M A BLE Wi F i C HRON O - T HERM O S TAT
WIT H H E ATIN G F UNCT I O N - BATT E R Y OPER A TED WI T H B OILE R O U TPUT
Page 2
24
25
26
27
28
15
14
13
12
11
10
16
17
18
19
20
21
22
23
29
30
ESC
MENU
ENTER
1
2
3
4
5
20
19
18
17
16
15
21
23
24
26
27
28
25
22
7
8 9 10
12 1411
6 13
31
BOILER
29
30
POWER/ OPERATION
BURNER
31
Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate / Deactivate boiler (valid only for the BS-851/T) Go to the next item or selection Select normal or night program Go to the previous item or selection Select and confirm installation settings Daily program activation indicator Weekly program activation indicator Manual program activation indicator Day of the week indicator Night program activation indicator Burner activation indicator Boiler activation indicator (valid only for the BS-851/R) Normal program activation indicator
Power supply and programming status indicator
Burner activation indicator
Boiler activation indicator (valid only for the BS-851/R)
Wi
WPS
Button
Manual
Button
LD5
LD1
LD4
Programming
Key
Serial
Number
Figure 1
Page 2 from 13
940851000_09_001
Page 3
1. SMARTPHONE CONNECTION
1) Download for free our application from Google Play by scanning with your smartphone the QR code (Figure 2) or make a search typing “Olympia
electronics thermostat”.
2) In the start up screen press No account
yet? Create one (Figure 3). After finishing the process successfully you will have to confirm the e-mail address that you registered. With these data you can log in.
3) If you want to add a device to your home
network firstly you have to connect your smartphone to the network which your thermostat will be connected.
4) To add the thermostat to the application:
In the application touch the '+' icon to the bottom left corner of the screen (Figure
4). By selecting scan the QR Code with the camera scan the serial number located inside the receiver or scan the QR Code on the included card. Otherwise you can insert the serial number by typing the 32digit on the included card.
Figure 2
Figure 3
2
Figure 4
CONTENTS
CONTENTS
Setting up the device, page 3 Entering the MENU, page 5 Day or Night operation, page 5 Boiler activation selection, page 5 Presence selection, page 5 Keypad lock, page 6 Setting time-date, page 6 Setting the daily program, page 6 Setting the weekly program, page 6 Setting the limits of the manual program, page 7 Thermostat operation mode, page 7 Temperature indication unit, page 7
Screen illumination, page 7 Burner output indicator, page 7 Manual operation time, page 7 Differential value, page 7 Hour meter, page 8 Factory settings, page 8 Battery changing, page 8 Screen messages, page 8 Daily programming example, page 9 Weekly programming example, page 10 Communication errors, page 11
Page 3 from 13
940851000_09_001
Page 4
5) To set up the parameters of WiFi you can
do this either selecting WPS either Smart Config (Figure 5):
By WPS
Push the WPS button (Figure 1) and the r ec e i ve r ge t s i n WP S mo d e . Subsequently you have to push the WPS button on the router as shown in your smartphone’s screen (Figure 6).
By Smart Config
In field SSID (Figure 7) the name of the WiFi that you want to connect your thermostast must be visible. In field password (Figure 7) put the password of the WiFi. Subsequently you have to push the Manual button (Figure 1) on the thermostat and at the end the SEND icon from the application (Figure 7).
When they connect, the LD4 must blink every 2 seconds while the LD5 must be off which means there is internet connection.
By finishing the process successfully you will be able to guide to the main screen of the app and your device will be visible, furthermore you can control it.
The screen of the thermostat is refreshing every five minutes, therefore, the command from your smartphone might not be visible to the screen immediately but this does not mean that it is not executed.
Figure 5
Figure 6
Figure 7
Page 4 from 13
940851000_09_001
Figure 1
WPS
Button
Manual Button
LD5
LD1
LD4
Programming
Key
Serial
Number
Page 5
temperature is set to 18.0ºC. To deactivate the night program, press the key for more than 3", the symbol is replaced by the symbol .
3. Boiler ACTIVATION (available only on the BS-851/T).
This capability can be executed by pressing briefly the key, the backlight will be activated for 2" and the symbol will be shown on the top left corner of the screen. The built-in relay will send the command to the burner. The command will be active for as long as it has been preselected via the
ΜΕΝU setting with the indication
(Boiler time), or until the key is
pressed again. If the preselected Boiler value is 00 then the deactivation can be done only with the key. The Boiler command is independent from the other functions of the device and can be given even if the thermostat is deactivated (OFF state). The factory default Boiler time is 00 minutes.
4. AREA PRESENCE SELECTION (The thermostat is in the ON state).
In normal operation, the symbol shows the presence of people in the area and all the programs, which ever are selected, are executed normally. In limited absence from the area (from a few hours to a few days) there is the capability to execute the absence program. If the key is pressed for 3", the backlight will be activated for 2" and the symbol will be changed to .This command superimposes every other program. The selected temperature is shown on the screen if any of the or keys is pressed and can’t be changed. The value can be changed only with the selection (Absent temperature) of the
ΜΕΝU. The factory default setting of this
temperature is 16.0 ºC and can be altered from 6.0 to 30.0 ºC. To deactivate the absence mode, the key must be pressed for 3", then the thermostat will continue the execution of the program that was running before absence mode was selected.
GENERAL
When the plastic battery separator is removed the unit is automatically activated and shows all the screen indicators for 1",then the firmware version is shown and finally the screen enters final operation status. In the center of the screen you can see the current temperature. The clock has the hour 00:00, the date is 1 January (Friday) 2016 and the thermostat is inactive (OFF state). In this state the only available s el e c ti o n s a r e Bo i le r ac t i v a t i o n /deactivation (only for BS-851/ΚΙΤ) and entry to the settings menu. If the key is pr ess ed mo men tar ily , th e scr een illumination will be activated for 2" and the symbols , and ΜΑΝ will be shown which are the factory defaults.
1. ENTERING THE MENU (the thermostat in the OFF state).
To enter the menu settings press the button for more than 3". The screen will be illuminated and will stay illuminated during all the duration of the settings To navigate through the menu . items use the keys and . To change the value of a menu item use the keys and . Press the key to accept the change or press the key to go to the previous state. By pressing again the key our settings are saved. If no key is pressed for 2 minutes then the thermostat returns to normal operation while saving the changed settings.
2. SELECTING DAY OR NIGHT OPERATION MODE
(the thermostat is in the ON state and in manual operation).
If the key is pressed for more than 3" then the indication is deactivated and you can see the . This means that night operation mode has been selected. This selection replaces temporarily the manually selected temperature for as long as the night program is active. If one of the keys or is pressed then the set night program temperature is shown. (this can be changed from the setting (night) of the ΜΕΝU). The factory default night
MENU
ENTER
ESC
MENU
ENTER
ESC
ESC
ESC
Page 5 from 13
940851000_09_001
Page 6
MENU
ENTER
Page 6 from 13
940851000_09_001
5. KEYPAD LOCK (in any operation state).
If the keys and are pressed simultaneously for 3" (first the key and then the ), the screen will show the message and the keypad is locked. Which ever key is pressed after this will show the same message on the screen. All other function are executed normally. To unlock the keypad follow the same procedure and the screen will show the message .
6. SETTING THE TIME AND DATE (the thermostat is in the OFF state).
To enter time and date adjustment mode press the key for 3" as mentioned in paragraph 1. The backlight will be activated and the lower section of the screen will flash the message (Set Time). After that press briefly the key and the hours indicators will start to blink. Use the keys or to set the correct time. Pressing the key will cause the minutes indicators to blink and with the keys or change to the correct value. Pressing again the key you can adjust consecutively the year, month and date. You can see that the day names are changed automatically depending on the year, month and date. In normal operation the clock has leap year and daylight savings time correction.
7. SETTING THE DAILY PROGRAM.
(the thermostat is in the OFF state).
If immediately after entering the MENU parameters press the key then the blinking message (Day) will be shown on the bottom of the screen and the word
DAY on the top right. By pressing the
key the message (Program 1) is shown in place of the message. In the center of the screen and if programming is done for the first time you can see the message . By pressing the key the hours indicators blink and you can alter the setting by using the keys or . By pressing the key you can alter the minutes and the required temperature. With the key you can return to the initial position with the
blinking . With consecutive presses of the key you can select the remaining programs of the 24 hour cycle (10 in total) and can set the required time periods and temperatures as described above. Please note that for every program define only the start time since the end time is the start time of the next program. For example, if you desire a temperature of 23.0º C from 14:00 to18:00 in program 1 set the start time 14:00 at 23.0º C and the start time of the second program 18:00 with the desired temperature. The 24 hour time base starts at 00:00 and ends at 23:59'. The start time of the next program must also be bigger than the start time of the previous. If no more changes are required and when the program indicator is blinking (e.g. ) you can press the key to store all the changes and the screen will show the message . The programs that have not been adjusted are not taken into account.
8. ADJUSTING SETTINGS FOR THE WEEKLY PROGRAM. (the thermostat is in
the OFF state).
If immediately after entering the ΜΕΝU press the key for 2 times the message (7days) will be shown on the bottom of the screen and the word WEEK on the top right. On the top left of the screen there is the message ΜΟ (Monday) that shows the day that corresponds to the programming that follows. By pressing again the key the screen shows a blinking that determines the first program of Monday of the weekly program. The remaining procedure is as described in paragraph 7 (setting the daily program). Finishing the programming of the first day if you press the key while the program number is blinking (e.g. ) will show the blinking message . With the key you can select the day for which you want to alter the program as described above. If no other changes are required then press the key to save the setting to memory. The screen will show the message . It is stressed that at least one program must be adjusted for every day else the factory default temperature of 6.0 ºC will be used
MENU
ENTER
ESC
ESC
MENU
ENTER
MENU
ENTER
MENU
ENTER
MENU
ENTER
ESC
ESC
MENU
ENTER
Page 7
Page 7 from 13
940851000_09_001
for all the 24 hour base.
9. SELECTING THE UPPER AND LOWER
L I M I T S O F T H E M A N U A L TEMPERATURE ADJUSTMENT (the
thermostat is in the OFF state).
After enteri ng th e and by MENU consecutive presses of the key the message (High Temperature Limit) will be shown on the bottom of the screen as well as the initial value 30.0 ºC. By pressing the key you can change this temperature between the lower limit and the value of 30.0 ºC. By pressing the key and then immediately the key the lower section of the screen shows the message (Low Temperature Limit) as well as the initial temperature of 6.0 ºC. With the key you can adjust the value between 6.0 ºC and the value of the upper limit. The two limits define a temperature area that can be used by the user to enter the desired temperature. The selection of the limits influences the manual adjustment of the temperature and is independent from the operating mode of the unit (manual, daily weekly) and does not have any influence on the programs for daily or weekly operation.
10.OTHER MENU SETTI NG S (th e
thermostat is in the OFF state).
All the menu settings that follow can be changed by using the same method as described in the previous chapters. After entering the use the key to ΜΕΝU select the required setting. The messages are shown in the bottom section of the screen like this:
A. (Mode) OPERATION MODE.
One of three operation modes can be selected: (User) Manual mode (the symbol
ΜΑΝ. is shown on the top right of the
screen).
(Day) daily operation (the symbol
DAY is shown on the top right of the screen.
(7 Days) weekly program (the symbol
WΕΕK is shown on the top right of the
screen).
The factory default is .
Β. (Unit) TEMPERATURE UNIT.
The option are: or (Degree Celsius ή Degree Fahrenheit) and regard the display of the temperature in ºC or ºF. Depending on the selection, the symbol ºC or ºF are shown on the center right of the screen.
C . ( B a c k L i g h t ) S C R E E N ILLUMINATION.
With this setting you can turn off the screen illumination in order to conserve battery energy. If (ΟΝ) is selected then the screen illumination will be activated every time a key is pressed. If is selected then the screen illumination will be deactivated The factory default is .
D. (LED) BURNER OUTPUT INDICATOR.
This setting can deactivate the burner output indicator in order to conserve battery energy.. If (ON) is selected then when the burner output is active the indicator will briefly blink every second so the user has a knowledge of the state of the thermostat from a distance.. If (OFF) is selected
then the indicator is deactivated.
Ε. (Time Out) TEMPORARY TIME FOR MANUAL OPERATION.
With this setting you can determine the time period for which the manual temperature adjustment is valid. When the thermostat is running a daily or weekly program and you press the keys or , either you change the temperature through the application, then the thermostat enters briefly the manual mode for a time period that is determined by the setting . The value of this setting can be from 3 to 10 hours after which normal program execution is continued. The factory default is 3 hours.
F. (Differential) DIFFERENTIAL SETTING.
This setting determines the ” temperature wi n d o wbe tw ee n a ct iv at io n and
deactivation of the burner output. For example, if the room temperature is set to
23.0 °C then with a differential of 0.5 °C the output to the burner will be deactivated at
23.0 °C and will be reactivated at 22.5 °C.
MENU
ENTER
ESC
MENU
ENTER
Page 8
Page 8 from 13
940851000_09_001
The differential value can be set between
0.2 °C and 4.0 °C.
The factory default value is 0.2 °C.
G. (Heat/Cold). HEATING MODE.
The device can control only heating
units (e.g. diesel burners).
H. (Time) HOUR METER.
In this screen position you can see the total operation hours of the burner. This value can not be altered by the keypad but can be reset if the battery is removed. The maximum value is 9.999 hours.
I. (Factory settings) SELECTING THE FACTORY DEFAULT SETTINGS.
If for any reason there is the need to restore the thermostat to its factory default settings then this setting will restore then if you select and press the key .This does not affect the time and date settings. The factory default setting is .
11. CHANGING THE BATTERY
When the screen shows the symbol the unit warns the user that the batteries have limited energy and that they must be replaced in the next 3 weeks. To replace the batteries simple remove the cover (Fig. 2) to expose the battery compartment. Remove the batteries and within 30 seconds reinsert new ones in order to avoid a reset of the device. Should this happen it will require to adjust the time and date again. All other setting remain unaffected. Avoid replacing the batteries with the backlight activated, this will immediately reset the device and the hour meter. Take care of the battery orientation and insert the new batteries according to the graphic representation etched on the plastic base. The reverse installation will not harm the device but it will not permit it to operate. The battery life time has been design to be approximately one year. Factors that influence the battery life are prolong use of the keyboard with the backlight active, increased temperature and humidity as well as battery quality.
12. ANTI-ICE PROTECTION
If the room temperature in which the thermostat is installed falls below C, the unit activates the burner output irrelevant of the ON or OFF state of the thermostat to prevent ice build up. The burner output is active for as long as the temperature is below 5°C.
13. CLEANING THE THERMOSTAT
To clean the device use a damp cloth to remove any dust or stains from the covers. Do not use any liquid or dissolvers that will damage the plastic covers.
14. SCREEN MESSAGES
Following you can see a complete list of screen messages that can be seen by consecutively pressing the key: = =Time and date setting.Set Time
= = Daily program selection. Day = = Weekly program selection. Week = = Operation mode selection. Mode = = Temperature unit. Unit = = Screen illumination.Backlight = = Burner output indication LED. LED = = Manual temperature Time out time. = = Upper limit High Temperature Limit
for manual temperature adjustment. = = Lower limit Low Temperature Limit for manual temperature adjustment. = = Active boiler timeBoiler Time = = Differential for burner Differential relay.
= = Absence program.Absent = = Night program.Night = = Heat operation mode. Heat
= RF = Wirelless connection setting = = Factory default settings. Factory
MISCELLANEOUS INDICATIONS
= = keyboard lock.Lock = = unlock keyboard. Unlock = = Save settings to memory. Save = = Manual program User = = Celsius Degree Celsius
temperature unit.
= = Fahrenheit Degree Fahrenheit
temperature unit. = = Program number Program 1 to 10 from 1 to 10.
MENU
ENTER
Page 9
Page 9 from 13
940851000_09_001
FACTORY DEFAULT VALUES
The following values are the factory default setting of the thermostat:
Thermostat state = Inactive (OFF) Daily and weekly programs = Not set Selected temperature value = 23.0°C Normal or Night program = Normal Temperature unit = Degrees Celsius Screen backlight = Active (On) Burner activation indicator = Active (On) Presence/ Absence program = Presence Manual selection time = 3 hours Upper manual temperature limit = 30.0°C Lower manual temperature limit = 6.0°C Boiler operation time = 00 minutes (BS­851/T) Boiler state = Inactive (BS-851/T) Operation mode = Manual (User) Differential = 0.2° C Absence temperature = 16.0° C Night program temperature = 18.0° C Heating function= Heating Keypad state = Unlocked
DAILY PROGRAMMING EXAMPLE
Lets assume that you want to program the foll owing te mperat ures and ho urs (programs): From 07.00 to 08.30 at 22,5°C. From 8.30 to 12.00 at 21,5°C. From 12.00 to 17.30 at 18.5°C. From 17.30 to 23.00 at
22.5°C and from 23.00 to 07.00 at 19,8°C.
Note that the end hour of each program is the start hour of the next program and always the start hour of a program is at least 1 minute greater than the end hour of the previous program. It is essential to select at least 1 program per day otherwise the thermostat will operate with the factory defined temperature of 6°C. Also note that the first program is considered the program with the start hour nearest to the hour 00.00 (e.g. 07.00).
1. Turn OFF the thermostat by pressing the
corresponding key.
2. Press continuously the key for 3
seconds The screen back light is activated . and the screen shows . Now you are in programming mode of the thermostat parameters.
3. Press the key 9 times and the screen
shows with the (Mode) blinking.
4. Press the key and the starts to blink. With the keys and select the operation mode (Day - daily program).
5. Press the key to return to the previous screen with the blinking.
6. Press the key 8 times and the screen shows with the blinking. Now you are in the daily programming sub menu that has a 10 program capability.
7. Press the key and the screen shows with the blinking, this shows that you are in program 1 of the daily program (the indication indicates that the current program in empty).
8. Press the key and the hours digit starts to blink. With the keys and
select 07.
9. Press the key and the minutes digit starts to blink. With the keys and select 00.
10. With the next press of the key
the screen shows the temperature blinking and by using the and keys you select 22,5°C. This concludes the programming of the first program.
11. Press the key and the screen shows the symbol blinking.
12. Press the key and the symbol will blink. This shows that you are in the second program.
13. Follow the step 8, 9 and 10 and set the time to 8.30 (which is the end time of the first program) and the temperature to 21,5°C.
14. Following the steps 8, 9, 10 and 11 to adjust the remaining programs with the values 12.00/18,5°C, 17.30/22,5°C and
23.00/ 19.8°C. If by mistake you add a new program (ex. Ρ6), this program can’t be canceled but can be defined as a new program with a start time of 23.01 and the same temperature as Ρ5.
15. Completing the daily program you can store the programmed values to the devices memory by pressing 2 times the
key while the indication is blinking. The screen will show for awhile and then normal operation will continue. By activating the device with the key the daily program will start to take affect. In order for the program to execute correctly make sure you have programmed the
MENU
ENTER
MENU
ENTER
ESC
DAY
MENU
ENTER
MENU
ENTER
ESC
ESC
Page 10
Page 10 from 13
940851000_09_001
device clock with the correct time.
WEEKLY PROGRAMING EXAMPLE.
The weekly program in general is based on the daily programming which is repeated for every day of the week independently. For the days of the week that have not been programmed, the values of the last programmed day are valid. For example, if you program only the days Monday to Wednesday, then the programming for Wednesday will be used for the days Thursday to Sunday. If you program only the days Monday, Wednesday and Thursday then for Tuesday’s program the program from Monday will be used and for the days Friday, Saturday and Sunday the program from Thursday will be used.
1. Follow the steps 1, 2, 3, and 4 of the daily
programming. Select in the (Mode) section the setting and press the key .
2. Press 7 times the key and the
screen shows with the indication blinking. The symbol ΜΟ (Monday) means that you are ready to program the Monday program and the symbol WEEK that you are in weekly programming mode.
3. Press the key and the screen shows
. From now the procedure follows the steps 8-14 of the daily programming and you can set the required temperatures on the required time.
4. Completing the programming of the
Monday program press the key and the screen shows with the indication blinking. By pressing the
key, the day indicator changes to TU (Τuesday) you can repeat the steps for programming a new program for Tuesday. The same can be done for the rest of the days of the week.
5. The complet i on of the weekly
programming can be done by pressing the key when the indicator is blinking. The screen will show the message briefly and the settings will be stored in to the devices memory.
6. Activate the device using the key.
The weekly program will start to execute as defined. In order for the program to execute
correctly make sure you have programmed the device clock with the correct time.
WIRELESS CONNECTION SETTING
After installing the peripheral received (BS­851/R), press the programming key (Figure
1) until the indicator POWER/STATUS (LD1) starts to blink in a rapid manner. This shows that the unit is in programming mode. After activating the thermostat by removing the battery separation tape, go to the selection (the thermostat in the OFF state, prolonged press of the MENU/ENTER key and then 22 consecutive presses of the key lead us to the screen ). The number of dashes verifies the correct connection between the two devices and also shows the strength of the signal. The thermostat must be placed in such a position that will allow good signal strength which means that at least 2 dashes must be shown. If less that 2 dashes are shown the communication between the two devices is not good and can lead to communication errors and bad operation. To completion of the wireless installation procedure is done by pressing the key on the thermostat and by a prolonged press of the programming key on the peripheral until the POWER/STATUS(LD1) indicator stops to blink and remains ON.
MOUNTING
Select mounting areas away from heating elements, door and window openings and fireplaces and in general, away for all heat sources and away from drafts. Mount the thermostat at a height of about 1.5 meters and on an interior wall (The external wall have a lower temperature than the internal wall and can affect the device).
ESC
MENU
ENTER
ESC
ESC
ESC
Page 11
Page 11 from 13
940851000_09_001
Dimensions in mm
Dimensions in mm
Mounting hole spacings
COMMUNICATION ERROR
Errors can occur if for any reason the communication between the two devices is disrupted. The screen of the thermostat will show the message (Communication Error), the backlight of the screen will blink.
The interruption of the mains voltage causes the interruption of communication between the two devices. When the voltage is restored, the peripheral device-receiver activates the outputs according to the state be f ore the i n ter rup tio n, un til the communication is automatically restored with the thermostat (maximum delay of 6 minutes), so the outputs will change according to the new commands that will be given.
Mounting hole spacings
81,3
27,3
121,5
105
105
19
19
80mm
120mm
120mm
34mm
Wi
Page 12
Page 12 from 13
940851000_09_001
Installation procedure
Installation procedure
Fig. 1 Fig. 2 Fig. 3
To install the devices BS-850/T or BS-851/T, insert a flat blade screwdriver in the slot as shown in (Fig. 1). Press and lift the front cover. Remove the retaining screws and remove the plastic cover that contains the keys (Fig. 2). Use the supplied mount accessories to mount the unit according to the diagram of page 11. Install the base, align it using the built in vial and tighten the screw to secure it. Reinstall the plastic containing the keypad with care and fasten the screws with a maximum torque of 0,5 Nm. To activate the device, remove the battery separation tape (Fig. 3). Install the front cover with slight pressure and the device is ready to operate.
Fig. 4
To install the BS-851/R, remove the front cover with a screwdriver (Fig. 4). Mark and drill the mounting holes according to the
schematic in page 11. Mount the device using the supplied mounting accessories (Holes A and B) as shown in Fig.5. Do the electrical connections according to (Fig.5). Connect the phase to the L terminal and the neutral to the N terminal, this is used to power the device. The phase cable for the outputs is to the common of the relay contacts. In every activation, the contacts will provide the phase to the burner. Avoid installing the phase internally (from the L terminal to the relay common terminals) because it might cause interferences. The outputs are not fuse protected so any short circuit will destroy them and the device.
N
L
230V~
Boiler Indicator (BS-851)
LD5
LD4
Boiler (BS-851/R)
Burner
Fig. 5
Burner Indicator
A
B
WPS Button
Manual Button
Power/Status
Indicator
Programming button BT1
Page 13
Page 13 from 13
940851000_09_001
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to
the premises of our company for repair or replacement, as long as the warranty period is valid. Olympia Electronics reserves the right to repair or to replace the returned
goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr info@olympia-electronics.gr
TECHNICAL CHARACTERISTICS
POWERED BY
2 Alk alin e ΑΑ
BS-850/T - BS-851/T BS-850/R - BS-851/R
MODEL
220 - 2 40V AC / 50- 60Hz
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
TYP ICAL WEIG HT GUA RANT EE
MEASURING RANGE
OPEN RELAY CONTACT
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
2x5 Α - 250V AC1
o
0.0 t o 99.9 C
EN 61 000- 6-1, EN 6 1000- 6-3, E N 60730 -1, EN 60 730- 2-9
o
5 to 35 C
10 - 90 % RH
2 yea rs
121.5 x 27.3 x 81.3 mm
IP2 0
175 g r. (with b atter ies) 200 g r.
o
-10 t o 50 C
10 - 95 % RH
120 x 34 x 80 mm
-
CONSUMPTION
1.9 VA
WARRANTY
WARRANTY
-
COMMUNICATION FREQUENCY
869 ,75M Hz
TEMPERATURE SELECTION RANGE
o
6.0 t o 30.0 C
-
-