THIS ONLINE MANUAL IS FOR PLANNING PUPOSES ONLY. CAREFULLY READ
BEFORE PURCHASING. REFER TO INSTALLING MANUAL PROVIDED WITH YOUR
APPLIANCE FOR MOST RECENT INSTALLATION AND OPERATING
INSTRUCTIONS FOR YOUR APPLIANCE.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance
WHAT TO DO IF YOU SMELL GAS:
*Do not try to light any appliance.
*Do not touch any electrical switch; do not use any phone in your building.
*Immediately call your gas supplier from a neighbors phone. Follow the gas
supplier’s instructions.
*If you cannot reach your gas supplier; call the fire department.
Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
This is an unvented gas fired heater. It uses air (oxygen) from the room in which it
is installed. Provisions for adequate combustion and ventilation air must be
provided. See Section 2
1
INCHES TO NON
0
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
The Old Salem Regency coal set is a ventless appliance consisting of an
integrated burner control and a simulated coal fire. There are no loose parts
nor any field assembly required.
MODELS
R400IGV36 BV3ON 19.5”W F, 17.5”W
B,
12” D, 14.75” Fl
BRWR400I
GV36BV3ON
WR400I 0V39
BV3ON
BRWR400I 6V39
BV3ON
19.5” W F, 17.5” W
B,
12” D, 14.75” H
16” W F, 14” W B
,l2” D,14”H
16” W F, 14” W B
,12” D., 14” H.
SIZE
-
COMBUSTIBLE
S
0 Sides, 0 Back,
0 Floor.
0 Sides, 0
Floor
0 Sides, 0 Back,
0 Floor
0 Sides, 0 Back,
0 Floor
Back,
MINIMUM FIREPLACE
SIZE
19.5”W F, 17.5” W B,
12” D., 14.75” H
19.511 WF, 17.5” W 8,
12” D, 1475” H
16” W F,14” W 8,12” D,
14”H
16” W F, 14W B ,12” D,
14” H.
Maximum BTU for Natural Gas - 13,400 intake
Maximum BTU for Natural Gas Bedroom unit - 10,000 intake
Minimum BTU for Natural Gas - 9,000 intake
The Old Salem Regency coal set is a ventless heater appliance consisting of
integrated burner controls and a simulated coal fire. There are no loose parts or
any field assembly required. It is intended for installation in a masonry or noncombustible fireplace only. When installed in an existing fireplace, the flue must be
blocked to prevent down drafts from disturbing the flame patterns and the chimney
must be capped to prevent potential water damage to the appliance. See the
following section for additional requirements.
1) GENERAL INSTRUCTIONS - IMPORTANT SAFETY INFORMATION
WARNING: This appliance is for installation only in a solid fuel-burning fireplace.
WARNING: Before installing in a solid fuel-burning fireplace, the chimney flue and
firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified
chimney cleaner.
2
INTRODUCTION
WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts
that alter burner flame patterns.
WARNING: Do not use a blower insert, heat exchanger insert or other accessory
not approved for use with this heater.
(a) A fireplace screen must be in place when the appliance is operating. The
screen must have openings for introduction of combustion air.
(b) No combustible materials shall be placed or burned in the fireplace where the
appliance is installed.
(c) The “Old Salem coal set” is provided as a completed assembly with no loose
parts. If improper handling should result in one or more of the coals becoming
loosened, the coals must be repositioned in exactly the same position into which
they were first attached. Should there be any doubt as to that location or if the
coals will not remain in that position during operation, the unit must be repaired
by a factory approved repair man or returned for repair.
(d) Never burn solid fuels in a fireplace where a gas coal set is installed
(e) This unit complies with ANSI Z21.11.2 Unvented Heaters.
(f) The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.
(g) The flow of combustion air MUST NOT be obstructed.
(h) Provide adequate clearances around air openings into the combustion
chamber and adequate accessibility clearance for servicing and proper
operation. NEVER obstruct the front opening of the appliance.
(i) Solid-fuels shall not be burned in a masonry or UL 127 factory-built fireplace in
which an unvented room heater is installed.
(j) Any safety screen or guard removed for servicing must be replaced Prior to
operating the appliance.
(k) An unvented room heater having an input rating of more than 6,000 BTU per
hour shall not be installed in a bathroom.
(l) An unvented room heater having an input rating of more than 10,000 Bth per
hour shall not be installed in a bedroom.
(m) Correct installation of coals, proper location of the heater and annual
cleaning are necessary to avoid potential problems with sooting. Sooting,
3
resulting from improper installation or operation, can settle on surfaces outside
the fireplace.
(n) Note: Installation and repair should be done by a qualified service person. The
appliance should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative that the control
compartment, burners and circulating air passageways of the appliance be kept
clean.
(o) An unvented room heater intended for installation in a solid-fuel burning
fireplace shall comply with these instructions.
(p) This heater is equipped with a PILOT LIGHT SAFETY SYSTEM designed to
turn off the heater if not enough fresh air is available.
(q) DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM
(r) If heater shuts off, do not relight until you have provided fresh air. If heater
keeps shutting off, have it serviced. Keep burner and control compartment clean.
Call your installer or Old Salem Hearths.
(s) It is critical that the burner be installed level to prevent sooting
WARNING: Do not use this room heater if any part has been under water.
WARNING: When used without adequate combustion air, heater may give off
CARBON MONOXIDE, an odorless, poisonous gas.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may
result in sooting and property damage.
WARNING: State or local codes may not allow operation of unvented appliances.
Check your state or local codes.
WARNING: Any outside air ducts and/or ash dumps in the fireplace shall be
permanently closed at the time of appliance installation.
WARNING: Any glass doors shall be fully opened when the appliance is in
operation.