
Issue Department: Date:
2019.01.07
Instruction of RF27
1 Key description
1.1 appearance
System Instruction
ruction of RF27
Inst
Author:
Edition:
Page 1 of 5
V0.0
Figure1buttonofremote
1/5

Issue Department: Date:
2019.01.07
Instruction of RF27
2 Key description
System Instruction
Author:
Edition:
Page 2 of 5
V0.0
Buttons
&LEDs
B1: CHILD LOCK
B2: PAIR
Key value Specification
Press and hold child lock button till the backlight
flashes remote enters locking or unlocking mode.
press and hold pair button
mode
2/5
,the remote enters pairing

Issue Department: Date:
2019.01.07
System Instruction
Instruction of RF27
B3: M
B4: FLASH LIGHT
B5: ZG
B6: HEAD UP
Click M button, the
and hold M button for 5s, until backlight flashes,
the control set the current position as M position
Click FLASH LIGHT button, open or close flash
light
Click zeroG
position, press and hold zeroG button for 5s, until
backlight flashes, the control set the current
position as zeroG position
Press and hold head up button, head actuator moves
out, stop when released
Author:
Edition:
Page 3 of 5
bed moves to M position, press
button, the bed moves to zeroG
V0.0
Click TV/PC button, the be
B7: TV/PC
B8: FOOT UP
B9: FLAT Press and hold flat button, the bed goes flat
B10: FOOTDOWN
B11: ANTI SNORE
B12: HEAD DOWN
B13: LOUNGE
B14: MASSAGE HEAD
position, press and hold TV/PC button for 5s, until
backlight flashes, the control set the current
position as TV/PC position
Press and hold foot up button, foot actuator moves
out, stop when released
Press and hold foot down button,foot actuator
moves out, stop when released
Click antisnore button, the bed moves to antisnore
position, press and hold antisnore button for 5s until
backlight flashes, the control set the current
position as antisnore position
Press and hold head down button, head actuator
moves out, stop when released
Click lounge button, the bed moves to lounge
position, press and hold lounge button for 5s, until
backlight flashes, the control set the current
position as lounge position
Click massage head button to switch massage
intensity of head massage motors
d moves to TV/PC
B15: TIMER Click timer button to switch massage time
B16: MASSAGE FOOT Click massage foot button to switch massage
3/5

Issue Department: Date:
2019.01.07
System Instruction
Instruction of RF27
intensity of foot massage motors
B17:
B18:
B19: MASSAGE TYPE Click massage type button to switch massage mode
LED 1: LED 1 Massage time: 10 minutes
LED 2: LED 2 Massage time: 20 minutes
LED 3: LED 3 Massage time: 30 minutes
MASSAGE
ON/OFF
UNDER BED
LIGHT
Click massage on/off button to turn on/off head &
foot massage motors
Click under bed light button to turn on/off the under
bed light
Author:
Edition:
Page 4 of 5
V0.0
Press and hold zeroG and flat button for 5s until
Other function
1:
Zero G + Flat
backlight
flashes, the memory positions of control box reset
to default settings
FCC Warning:
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
4/5

Issue Department: Date:
2019.01.07
System Instruction
Instruction of RF27
Author:
Edition:
Page 5 of 5
V0.0
ISED RSS Warning:
This device co
licenceexemptRSS standard(s). Operation is subject to the following two conditions: (1) this
devicemay not cause interference, and (2) this device must accept any interference,
includinginterference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radioexempts de
licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,même si le
brouillage est susceptible d'en compromettre le fonctionnement.
ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled
environment.The device has been evaluated to meet general RF exposure requirement.
Le matériel est conforme aux limites de dose d'exposition aux rayonnements énoncés pour fac un
autre environnement.ce dispositif a été évalué à satisfaire l'exigence générale de l'exposition aux
rf.
mplies with Innovation,Science and Economic Development Canada
5/5

JL DP .1 4. 02 7. 00 0
JL DP .1 0. 02 3. 00 0
JL DP .0 5. 03 2. 00 0
16 .0 1. 01 5C
R5 .2
FCC ID: PCU-RF27
IC: 21319-RF27
R5 .5 04 .0 1. 25 0
R5 .2 17 .0 1. 01 6
R5 .4 13 .0 1. 00 5
CB .1 3. 22 .0 1
FCC ID: PCU-CB1322
IC: 21319-CB1322
R5 .4 10 .0 1. 00 9
R5 .1 13 .0 0. 01 1
JL DQ .9 .0 01 .1 30 C
B.1 5227
NO.
Product name
1 Head Motor
2 Foot Motor
Product code
B.15227
B.15226
3 Massage Motor JLDQ.9.001.130C 2
4
Massage Motor Cable
5 Control Box
6 Power Supply
R5.410.01.009 1
CB.13.22.01
JLDP.10.023.000
7 Power Cord R5.217.01.016 1
8
9
10
ANSI power cord
Y cable R5.216.01.015C 1
Patch cord of LED strip
R5.504.01.250 1
R5.413.01.005 1
11 LED strip/ LED R5.113.00.011 1
12 USB Socket/USB JLDP.05.032.000 1
13
14
Double USB Chager
19Keys remote
JLDP.14.027.000 2
RF27
B. 15 22 6
number
1
1
1
1
1