OJ Electronics MCD5-1999 Instruction Manual

67384B 06/16 (HKT)
© 2016 OJ Electronics A/S
MCD5-1999
MCD5-1999
INSTRUCTIONS
• English
GREEN COMFORT
MCD5-1999
BR1017A02
BR1017A01
ILLUSTRATIONS
Pages .................................................................................... 3
INSTRUCTIONS
English .................................................................................. 7
Fig. 1
BR1017A01BR1017A02
Fig. 2
2
© 2016 OJ Electronics A/S © 2016 OJ Electronics A/S
© 2016 OJ Electronics A/S
3
MCD5-1999 MCD5-1999
BR1017A05A
653 421
N
L
BR1017A06
Fig. 3
BR1017A03A
Fig. 5
L N
BR1017A05A
Fig. 4
1.5m
BR1017A03a
653 421
BR1017A05aBR1017A06
Fig. 6
1
3
2
BR1017A04c
4
© 2016 OJ Electronics A/S
© 2016 OJ Electronics A/S
5
MCD5-1999
1
NTC 12k@ 25°Celsius
°Celsius
°Fahrenheit
Ohm (Ω)
-10°C 14°F 55076
0°C 32°F 34603
10°C 50°F 22284
20°C 68°F 14675
30°C 86°F 9860
Fig. 7
MCD5-1999
1
2
Instruction English
Fig. 8
ON
OFF
Fig. 9
6
4
4
Manual
Auto
3
FIG. 1 - CONTENT
• Thermostat
• Sensor
The thermostat is an electronic PWM/PI thermostat for temperature control by means of an NTC sensor located either externally or
BR1017A14BR1017A07
internally within the thermostat. The thermostat is for flush mounting in a wall socket. A baseplate for wall mounting is also available.
BR1017A07
This thermostat can be used as a controller for electric room heating pursuant to EN50559.
Product programme
OCD5-1999/MCD5-1999 Clock-thermostat with two sensors:
2
Menu
floor sensor and built-in room sensor.
FIG. 2 - WARNING – Important Safety Instructions
Disconnect the power supply before carrying out any installation or maintenance work on this thermostat and associated components. The thermostat and associated components should only be installed by a competent person (i.e. a qualified electrician). Electrical instal­lation must be in accordance with appropriate statutory regulations.
FIG. 3 - THERMOSTAT PLACEMENT Mounting of sensor
The floor sensor contains a safety extra-low voltage (SELV) circuit, allowing it to be placed as close to the floor surface as possible without having to take account of the risk of shock should the sen­sor cable become damaged. The two wires connecting the sensor to the mounting box must be additionally insulated, e.g. shrink flex. To prevent loose wires in the fixed installation from coming into contact with the terminal block for the floor sensor, they must be restrained using cable ties.
BR1017A17
© 2016 OJ Electronics A/S
© 2016 OJ Electronics A/S© 2015 OJ Electronics A/S
7
MCD5-1999 English
It is strongly recommended that the cable and sensor are placed in a non-conductive installation pipe embedded in the floor. The end of the pipe must be sealed and the pipe placed as high as possible in the concrete layer. Alternatively, the sensor can be embedded directly in the floor. The sensor cable must be led through a sepa­rate conduit or segregated from power cables. The floor sensor must be centred between loops of heating cable.
The sensor cable may be extended up to 100 m by means of a separate two-core cable. Two vacant wires in a multi-core cable used, for example, to supply current to the floor heating cable must not be used. The switching peaks of such current supply lines may create interference signals that prevent optimum thermostat func­tion. If a shielded cable is used, the shield must not be connected to earth (PE). The two-core cable must be placed in a separate pipe or segregated from power cables in some other way.
Mounting of thermostat with built-in sensor
The room sensor is used for comfort temperature regulation in rooms. The thermostat should be mounted on the wall approx.
1.6 m above the floor in such a way as to allow free air circulation around it. Draughts and direct sunlight or other heat sources must be avoided. No external sensor is connected.
FIG. 4 - OPENING THE THERMOSTAT
1. Slide the power button down to O “0”.
2. Release the front cover ONLY by inserting a small screwdriver into the slot at the centre of the bottom side of the front cover to press and hold the catch securing the front cover.
3. Then carefully pull the front cover away, initially from the lower part of the thermostat, then from the upper part of the thermo­stat.
MCD5-1999 English
FIG. 6 + 7 - MOUNTING THE THERMOSTAT
1. Mount the thermostat in the wall socket.
2. Fit the frame and carefully press the cover onto the thermostat
- starting with the upper part of the cover, then the lower part of the cover. Ensure that both the power slide button on the cover and the power switch pin in the thermostat are down.
3. Click the cover into place by applying light, even pressure. Warning! Do not apply pressure to the corners of the display cover or to the display itself.
DO NOT open the thermostat by releasing the four fixing clips on the back.
FIG. 8 - OPERATING THE THERMOSTAT
There is an ON/OFF switch on the left side of the thermostat: up is ON - down is OFF. The resistive touchscreen requires a soft tap with your fingertip to register the touch. Installer Wizzard: The first time the thermostat is connected, push the power slide button to On “I” The Installer Wizard on the touchscreen will guide you through the set up of:
1. Region
2. Language
3. Date
4. Time
5. Floor Type
Programming
See user manual. http://www.ojelectronics.com/OCD5
FIG. 5 - CONNECTIONS
Connect the wires in accordance with the diagram. The wires must be connected as follows: Term. 1: Neutral (N) Term. 2: Live (L) Term. 3-4: Output, max. 16 A Term. X: Do not connect Term. 5-6: External floor sensor
8
© 2016 OJ Electronics A/S
© 2016 OJ Electronics A/S
9
MCD5-1999 English
FIG. 9 - TROUBLESHOOTING
If the sensor is disconnected or short-circuited, the heating system is switched o. The sensor can be checked against the resistance table.
Error codes
E0: Internal fault. The thermostat must be replaced. E1: Built-in sensor defective or short-circuited. Replace the ther-
mostat, or use the floor sensor only.
E2: External sensor disconnected, defective or short-circuited.
Reconnect the sensor if disconnected, or replace the sensor.
E5: Internal overheating. Inspect the installation.
CE marking
According to the following standard: LVD/EMC: EN 60730-2-9
Classification
Protection from electric shock must be assured by appropriate installation. Appropriate installation must meet the requirements of Class II (enhanced insulation).
Environment and recycling
Please help us to protect the environment by disposing of the packaging in accordance with national regulations for waste processing.
MCD5-1999 English
TECHNICAL DATA
Voltage ........................................................................ 100-240 VAC
Max. pre-fuse .............................................................................16 A
Built-in circuit breaker .................................................. 2-pole, 16 A
Output relay ........................................... make contact - SPST - NO
Output .............................................................................. max. 16 A
Terminal wire size ......................................................... 1.5-2.5 mm2
Control principle .................................................................. PWM/PI
Standby power ........................................................................ 0.5 W
Battery backup ..................................................................... 5 years
Action type .................................................................................. 1.B
Software class .................................................................................A
TB ............................................................................................ 125°C
ELV limits realized ............................................................. SELV 24 V
Pollution degree rating.....................................................................2
Rated impulse voltage ............................................................... 4 kV
Enclosure rating ........................................................................ IP 21
Dimensions .................................................. H/115, W/84, D/40 mm
Build-in depth ........................................................................ 23 mm
Display ...................................... 176x220 pixel TFT - resistive touch
EU registered design .................................................... DM/082270
The thermostat is maintenance free.
Recycling of obsolete appliances
Appliances with this label must not be disposed of with general household waste. They must be collected separately and disposed of in compliance with local regulations.
10
© 2016 OJ Electronics A/S
© 2016 OJ Electronics A/S
11
MCD5-1999
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg Tel.: +45 73 12 13 14 · Fax +45 73 12 13 13 oj@ojelectronics.com · www.ojelectronics.com
The trademark is registered and belongs to OJ Electronics A/S · © 2016 OJ Electronics A/S
12
© 2015 OJ Electronics A/S
Loading...