1. Introduction
Thank you for purchasing an Ohm loudspeaker.
To guarantee the best possible operating of the equipment and avoiding any malfunction of the system, please read this manual carefully before use. For your own safety we recommend you take the time to read all the warnings and precautions contained within this manual and study the connection details to ensure correct usage and avoid any misuse which may invalidate your warranty.
Record the model and serial number, found on the back of the unit, in the spaces designated on the warranty card and also somewhere safe for future reference. Refer to the model and serial number whenever you call upon your dealer for information or service on this product.
All information contained in this manual is based on information available at the time of going to press. The information has been carefully checked for accuracy, however no guarantee is given with respect to the correctness.
Ohm (UK) accepts no responsibility for any errors or inaccuracies that may appear in this manual or the information on any products described in it.
Technical specifications, dimensions, weights and properties do not represent guaranteed qualities.
As manufacturers we reserve the right to make alterations and modifications within the constitution of the law, as well as changes aimed at improving quality.
This manual does not include all of the details of design, production or variations of the equipment. Nor does it cover every possible situation that may arise during installation, operation or maintenance. If you need particular assistance beyond the scope of this manual please contact your local dealer and if further assistance is require contact our technical personnel.
Before setting up a system read this manual and its safety instructions and keep the manual readily available on site.
If the product requires repair or if information about the warranty is needed, please contact an approved Ohm distributor or the Ohm factory. The contact details are available on the Ohm website.
CT-8 / 10 / 12 / 15 Full Range Loudspeakers
Version 2.0
3
2. Warranty
All Ohm products have 2 years warranty covering any faults in materials ormanufacturing. Warranty does not cover any damage caused by using the products against Ohm UK’s recommendations.
1.1. Unpacking
Carefully open the shipping carton and check for any noticeable damage. Verify that all the items are included, please contact your dealer if any parts are missing.
Every Ohm loudspeaker has been rigorously tested and inspected before being carefully packaged, prior to shipping. If any damage has occurred to the packaging or the unit during transit, please notify the delivery company as soon as possible. Only the consignee can file a claim against the carrier for shipping damage.
We recommend that you retain the original carton and packing materials for use should you transport or ship the unit in future.
Declaration of CE Conformity
This equipment has been tested and found to conform to the requirements of the:
EMC Directive 89/336/EEC, Machinery Directive 2006/42/EC Low Voltage Directive 2006/95/EC
and to the following standards:
EMC Emission EN55103-1 (1996)
EMC Immunity EN55103-2 (1996)
Electrical Safety EN60065 (1998)
Mechanical Safety EN ISO 12100-1 (2004)
CT-8 / 10 / 12 / 15 Full Range Loudspeakers
Version 2.0
4
For more details (UK), check The Control of Noise at Work Regulations 2005.
Noise Level (dBA) Maximum Exposure Time per 24 Hours
85 8 hours
88 4 hours
91 2 hours
94 1 hour
97 30 minutes
100 15 minutes
103 7.5 minutes
106 3.7 minutes
109 112 seconds
112 56 seconds
115 28 seconds
118 14 seconds
121 7 seconds
124 3 seconds
127 1 second
130-140 less than 1 second
140
NO EXPOSURE
Maximum Recommended Noise Dose Exposure Levels
3. Important safety instructions
1. Read this manual
2. Heed all safety warnings
3. Follow all instructions
4. The user should never incorporate equipment or accessories not approved by Ohm
5. Safety warnings Sound systems are capable of producing high sound pressure levels which can lead to a hearing damage especially in long term exposition.
To prevent damage to hearing avoid being too close to speakers in operation.
The generally accepted standard to minimize hearing risk is based on an exposure to 85 dBA for a maximum limit of eight hours per day, followed by at least ten hours of recovery time at 70 dBA or lower (at which the risk of harm to healthy ears is negligible). Then a “3 dB exchange rate” formula is applied, which means that for every 3 dB above 85 dBA, the maximum exposure time is cut in half.
Noise levels above 140 dB are not considered safe for any period of time, however brief. For children, the World Health Organization recommends no exposure above 120 dB.
CT-8 / 10 / 12 / 15 Full Range Loudspeakers
Version 2.0
5
6. Speakers have a permanent magnetic field even when they are not operating. Magnetic fields can cause faults for magnetic data media and monitors, therefore it is important to keep all speakers always at least 1m away from these kinds of equipments.
7. Do not expose the product to long term moisture (rain, sea spray, shower or steam) or put in direct contact or partially immersed in water.
8. System parts and rigging inspection Be sure to follow the relevant national specifications, norms, and safety regulations. The information described here does not relieve the user of the duty to follow the given safety requirements and legal regulations.
All system components must be inspected before use, in order to detect any possible defects. Please refer to the “Care and Maintenance” section for more instruction.
Any parts showing any sign of defect must immediately put aside and withdrawn from use to be inspected by qualified service personnel.
9. Mounting Any mounting of the product should follow the manufacturer’s instruction given in this manual, and should use a mounting accessory recommended by the manufacturer.
10. Condition which require immediate service Servicing is required when the product has been damaged in any way such as:
• The product has been exposed to excess rain or moisture
• The product was dropped or the enclosure is damaged
• The product does not operate normally
CT-8 / 10 / 12 / 15 Full Range Loudspeakers
Version 2.0
6
CT main systems
CT-8, CT-10, CT-12 & CT-15 for main systems and arrays
CT-8, CT-10, CT-12 and CT-15 are the largest top cabinets in this range. Designed for both install and mobile use these speakers offer great flexibility to suit even the most difficult applications. Side walls with 20 degree wall angle together with 40 degree horizontal dispersion and the rotatable horn allows true seamless point source arrays to be created easily with the innovative flying system.
Phase and impedance corrected crossover networks are designed for high power applications and the use of external EQ provides unrivalled tonal balance and transient response. Used with the CS subwoofers these systems will provide a very high SPL with total clarity.
CT-8 & CT-10
Key Features / Technology
• Matching voicing with the CW cabinets.
• Rotatable 90 x 40 horn
• High SPL in a compact cabinet
Use For
Small and medium installs and AV
full range applications
Use With
Small to Medium CS subwoofers
Ohm controller & software is
required
Mounting Options
TH-1 top hat fitted as standard
Brownline compatible flying points
top, bottom and back
CT-12 & CT-15
Key Features / Technology
• True full range performance
• Rotatable 60 x 40 horn
• Full range for standalone use where space is constricted
Use For
Installations & AV applications
requiring high SPL, wide and smooth
coverage
Use With
Large CS subwoofers
Ohm controller & software is
required
Mounting Options
TH-1 top hat fitted as standard
Brownline compatible flying points