1.2 Overview of Parts and Controls ...................................................................................................................EN-5
1.3 Control Functions .......................................................................................................................................EN-9
3.1 Menu Structure ........................................................................................................................................EN-13
3.2 Menu Navigation .....................................................................................................................................EN-14
3.3 Calibration Menu .....................................................................................................................................EN-14
3.3.4 End Calibration .............................................................................................................................EN-16
3.4 Setup Menu .............................................................................................................................................EN-18
3.4.2 Legal for trade .............................................................................................................................. EN-18
3.4.3 Calibration Unit .............................................................................................................................EN-18
3.4.6 Power On Unit ..............................................................................................................................EN-20
3.4.7 Zero Range ..................................................................................................................................EN-20
3.4.8 Retain Zero Data ...........................................................................................................................EN-20
3.4.9 End Setup ....................................................................................................................................EN-20
EN-13000 Series Indicators
EN-23000 Series Indicators
TABLE OF CONTENTS (Cont.)
3.5 Readout Menu ......................................................................................................................................... EN-21
3.5.8 Auto Off Timer ..............................................................................................................................EN-22
3.5.10 End Readout ................................................................................................................................. EN-22
3.6 Mode Menu .............................................................................................................................................EN-23
3.6.6 End Mode ....................................................................................................................................EN-23
3.7 Unit Menu ...............................................................................................................................................EN-24
3.7.2 Kilogram Unit ...............................................................................................................................EN-24
3.7.3 Pound Unit ...................................................................................................................................EN-24
3.7.4 Gram Unit ....................................................................................................................................EN-24
3.7.5 Ounce Unit ...................................................................................................................................EN-24
3.7.6 Pound Ounce Unit .........................................................................................................................EN-24
3.7.7 End Unit ......................................................................................................................................EN-25
3.8 Print Menu ..........................................................................................................................................EN-25
3.8.4 Stop Bit .......................................................................................................................................EN-26
3.8.6 Print Stable Data Only ...................................................................................................................EN-26
3.8.7 Auto Print .....................................................................................................................................EN-26
3.8.9 End Print .....................................................................................................................................EN-26
3.9 Lock Menu ..............................................................................................................................................EN-27
3.9.6 Lock Unit .....................................................................................................................................EN-27
3.9.8 End Lock .....................................................................................................................................EN-28
TABLE OF CONTENTS (Cont.)
3.10 End Menu ..............................................................................................................................................EN-28
4.2 Zero Operation .........................................................................................................................................EN-28
4.4 Changing Units of Measure .......................................................................................................................EN-29
4.5 Printing Data ........................................................................................................................................... EN-29
4.6.2 Parts Counting .............................................................................................................................EN-29
5. SERIAL COMMUNICATION ..........................................................................................................................EN-34
5.2 Output Format ......................................................................................................................................... EN-35
EN-33000 Series Indicators
6. LEGAL FOR TRADE ................................................................................................................................... EN-36
6.3.2 Audit Trail Seal .............................................................................................................................EN-37
7.1 Model T32M Cleaning ..............................................................................................................................EN-38
7.4 Service Information .................................................................................................................................. EN-38
8. TECHNICAL DATA .....................................................................................................................................EN-40
8.2 Accessories and Options ...........................................................................................................................EN-41
8.3 Drawings and Dimensions ........................................................................................................................EN-41
This manual contains installation, operation and maintenance instructions for the T32M Indicators. Please read this manual
completely before installation and operation.
1.1 Safety Precautions
For safe and dependable operation of this equipment, please comply with the following safety precautions:
• Verify that the input voltage range printed on the data label matches the local AC power to be used.
• Make sure that the power cord does not pose a potential obstacle or tripping hazard.
• Use only approved accessories and peripherals.
• Operate the equipment only under ambient conditions specified in these instructions.
• Disconnect the equipment from the power supply before cleaning.
• Do not operate the equipment in hazardous or unstable environments.
• Do not immerse the equipment in water or other liquids.
• Service should only be performed by authorized personnel.
1.2 Overview of Parts and Controls
EN-53000 Series Indicators
1
2
3
4
5
6
TABLE 1-1. T32MC/T32ME PARTS.
ItemDescription
1Data Label
2Front Housing
3Adjusting Knob (2)
4Control Panel
5Mounting Bracket
6Screw (4)
7Rear Housing
8Data Label
9Power receptacle
10Strain Relief for Load Cell
Cable
11RS232 Connector
7
8
9
Figure 1-1. T32MC/T32ME Indicator.
1011
EN-63000 Series Indicators
1.2 Overview of Parts and Controls (Cont.)
J2
J1
SW5
LFTONLFTOFF
J3
W2
J7
W1
Figure 1-2. Main PC Board.
TABLE 1-2. MAIN PC BOARD.
ItemDescription
1Line Power Input J1
2LFT On / Off Switch
3RS232 Connector J3
4Sense Jumper W2
5Load Cell Terminal Block J7
6Sense Jumper W1
1.2 Overview of Parts and Controls (Cont.)
EN-73000 Series Indicators
Figure 1-3. Controls and Indicators T32MC
TABLE 1-3. CONTROL PANEL.
No.Designation
1Capacity Label Window
2Pound indicator
3Ounce indicator
4Kilogram, gram indicator
5TARE
6CALIBRATION MODE indicator
7FUNCTION
8NET indicator
9PCS indicator
10PRINT
11Accumulation indicator
12Hold indicator
13ON/ZERO
14Center of Zero indicator
15Under LED
16Accept LED
17Over LED
18Stable weight indicator
Menu
Units
Off
button
Mode
button
button
button
EN-83000 Series Indicators
1.2 Overview of Parts and Controls (Cont.)
Figure 1-4. Controls and Indicators T32ME.
TABLE 1-4. CONTROL PANEL.
No.Designation
1Capacity Label Window
2Gram indicator
3Kilogram indicator
4Pound indicator
5Ounce indicator
6TARE Menu button
7CALIBRATION MODE indicator
8NET indicator
9FUNCTION
10PCS indicator
11Accumulation indicator
12Hold indicator
13PRINT
14Stable weight indicator
15ON/ZERO
16Center of Zero indicator
17Under LED
18Accept LED
19Over LED
Units
Off
Mode
button
button
button
1.3 Control Functions
Button
EN-93000 Series Indicators
TABLE 1-5. CONTROL FUNCTIONS.
Primary Function
(Short Press)
Secondary Function
(Long Press)
Menu Function
(Short Press)
ON/ZERO
If Indicator is On, sets
zero.
Off
Turns the Indicator on
or off.
Yes
Accepts the current
setting on the display.
PRINT
Sends the current value
to the COM port if
AUTOPRINT is set to Off.
Units
Changes the weighing
Unit.
No
Advances to the next
menu or menu item.
Rejects the current
setting on the display
and advances to the
next available setting.
Increments the value.
FUNCTION
Initiates an application
mode.
Mode
Allows changing the
application mode.
Press and hold allows
scrolling through modes.
Back
Moves Back to previous
menu item.
Decrements the value.
TARE
Performs a tare
operation.
Menu
Enter the User menu.
View the Audit Trail event
counters (extended
press)
Exit
Exits the User menu.
Aborts the calibration in
progress.
EN-103000 Series Indicators
2. INSTALLATION
2.1 Unpacking
Unpack the following items:
• Indicator
• AC Adapter
• Mounting Bracket
• Knobs (2)
• Capacity Label Sheet
• Instruction Manual CD
• Warranty Card
• LFT sealing Kit
2.2 External Connections
2.2.1 RS232 interface Cable to the indicator
Connect the optional RS232 cable to the RS232 connector Figure 1-1, item 11).
PinConnection
1N/C
2TXD
3RXD
4N/C
5GND
6N/C
7N/C
8N/C
9N/C
4
5
9
Figure 2-1. RS232 Pins.
2
3
1
78
6
2.2.2 AC Power
Connect the AC Adapter to the power receptacle (Figure 1-1, item 9), then plug the AC Adapter into an electrical outlet.
2.2.3 Mounting Bracket to the Indicator
Align the mounting bracket over the threaded holes in the side of the indicator and install the knobs. Adjust the indicator to the
desired angle and tighten the knobs.
EN-113000 Series Indicators
2.3 Internal Connections
Some connections require the housing to be opened.
2.3.1 Opening the Housing
CAUTION: ELECTRICAL SHOCK HAZARD. REMOVE ALL POWER CONNECTIONS TO THE INDICATOR
BEFORE SERVICING OR MAKING INTERNAL CONNECTIONS. THE HOUSING SHOULD ONLY BE OPENED
BY AUTHORIZED AND QUALIFIED PERSONNEL, SUCH AS AN ELECTRICAL TECHNICIAN.
Remove the four Phillips head screws from the rear housing.
Open the housing being careful not to disturb the internal connections.
Once all connections are made, reattach the front housing.
2.3.2 Scale Base to the indicator
Pass the load cell cable through the strain relief (Figure 1-1, item 10) and attach it to terminal block J7 (Figure 1-2, item 5).
PinConnection
J7-1+EXCITATION
J7-2+SENSE
J7-3+SIGNAL
J7-4GROUND
J7-5-SIGNAL
J7-6-SENSE
J7-7-EXCITATION
Jumper Connections
For a 4-wire load cell with no sense wires: Jumpers W1 and W2 must be shorted.
For a 6-wire load cell that includes sense wires, see Figure 2-2. Jumpers W1 and W2 must be opened.
For load cells with an extra ground shield wire: Connect the shield to the center position (GND) of J7.
Figure 2-2. Jumper Connections.
After wiring is completed and jumpers are in place, replace the indicator housing screws. Make sure the strain relief is properly
tightened.
EN-123000 Series Indicators
2.4 Mounting Bracket
Attach the bracket to a wall or table using fasteners (not supplied) that are appropriate for the type of mounting surface. The
bracket will accommodate up to 6 mm (1/4”) diameter screws. Locate the mounting holes as shown in Figure 2-3.
12.5mm
0.49 in.
Figure 2-3. Mounting Bracket Dimensions.
3 SETTINGS
3.1 Menu Structure
EN-133000 Series Indicators
TABLE 3-1. MENU STRUCTURE.
Loading...