Oertli OS3 Vitrex VC830201 User manual

Operating Instructions
OS3 Vitrex VC830201
VV016031E
0297
29.05.09 VV016031E 1
Instructions for using the Oertli OS3 VC830201 Vitrex Module
Contents Page
1 Application and description.........................................................................................................3
3 The control panel ........................................................................................................................4
3.1 Arrangement of control and indicator elements..........................................................................4
4 Foot switch and pedal.................................................................................................................5
4.1 Foot-operated switch (stand-alone operation) ............................................................................5
4.2 Duallinear pedal (interconnected operation)...............................................................................5
5 Supply connections / power on-off..............................................................................................5
5.1 Compressed air connection ........................................................................................................5
5.2 Electrical connection ...................................................................................................................5
5.3 Replacing fuses...........................................................................................................................5
6 Operation ....................................................................................................................................5
6.1 AIR ..............................................................................................................................................5
6.2 VISCO.........................................................................................................................................6
6.3 LUM light source .........................................................................................................................6
6.3.1 Changing lamps ..........................................................................................................................7
7 ParaProg settings........................................................................................................................7
8.1 Visual displays ............................................................................................................................7
8.2 Acoustic signals ..........................................................................................................................7
8.3 Voice confirmation.......................................................................................................................7
10 Cleaning and sterilisation instructions.........................................................................................7
10.1 Cleaning......................................................................................................................................8
10.2 Sterilisation..................................................................................................................................8
11 Accessories and replacement parts............................................................................................8
12 Authorised service centres..........................................................................................................8
13 Technical data.............................................................................................................................8
14 Overview of messages, warnings and error messages..............................................................9
15 Explanation of symbols...............................................................................................................10
16 Calibration and maintenance ......................................................................................................10
17 Disposal ......................................................................................................................................10
18 OS3 Vitrex VC830201, Overview................................................................................................11
29.05.09 VV016031E 2
1 Application and description
The OS3 Vitrex operating unit is used for surgical procedures in the posterior segment of the eye. It can be used as a stand-alone unit or, preferably, in conjunction with the OS3 VC830100 base unit. The functional features offered by the instrument include inter-ocular lighting, an air pump to maintain inner eye pressure and a pump for the injection and extraction of visco-elastic substances.
IMPORTANT!
Alterations and repairs may only be undertaken by persons
authorised by the manufacturer, otherwise the proper
functioning of the unit may be impaired.
CAUTION!
The unit must never be used in areas containing
inflammable anaesthetics!
The unit actuates and controls the accompanying instrumentation and consumable materials within the performance limit values selected by the operator in each case, and as set on the control panel. A foot pedal is used for the fine adjustment of these values within the specified range. The unit is extremely easy to operate. Frequently used settings can be stored and recalled.
The unit may only be used with the Oertli instruments and consumable materials recommended and supplied by the manufacturer (see Section 11).
The unit may only be operated by trained personnel. The surgeon is responsible for defining the correct settings.
The unit is not suitable for surgical interventions outside the eye. If in doubt, please contact the manufacturer.
2 Important points and hazards
IMPORTANT!
Please read these instructions very carefully before using
the apparatus for the first time!
IMPORTANT!
When setting up the unit, ensure that neither the rear
ventilation holes nor the top of the unit are covered.
CAUTION!
Never look directly into the lamps when they are lit!
IMPORTANT!
Mobile telephones and other appliances that use radio
frequencies may cause unexpected or undesirable
behaviour of the unit or system!
IMPORTANT!
Never place the unit or system next to or on top of other
appliances when operating it. If it is necessary to arrange
the appliances in this way, it must be checked in each case
that the unit or system is working correctly.
NOTE!
In order to avoid the risk of electric shock, this unit may
only be connected to mains supplies with a protective earth
connection.
IMPORTANT!
The user is responsible for ensuring compliance with and
fulfilment of IEC 60601-1
IMPORTANT!
Before connecting the unit, check that the voltage shown
on the rating plate is the same as that of the operating
room!
CAUTION!
The Visco instrument connections (INJCT and EXTR) must
never come into direct contact with the eye! If a syringe is
to be used as a silicone container, care must be taken to
ensure that there is no air in the syringe reservoir!
IMPORTANT!
While in the EXTR mode, ensure that liquid is never sucked
into the unit at the Visco instrument connection, especially
during the application of substances with a lower viscosity.
IMPORTANT!
The correct choice of equipment settings is the
responsibility of the surgeon!
Settings given in this instruction manual are suggestions
only.
IMPORTANT!
Only those instruments and accessories supplied by the
manufacturer and listed in Section 11 may be used!
29.05.09 VV016031E 3
The control panel
40 mmHg
0.50 bar
0.10 bar
All settings for operating the OS3 Vitrex unit can be entered on the control panel (pre-settings are entered in ParaProg, see Section 7). A visual display shows at a glance the operating state of the system and the current values.
The buttons respond to gentle pressure which can also be applied either with a sterile swab or the sterile operating pen (VE850003) available from the manufacturer.
Depending on the stage of the operation or the position of the control pedal, certain buttons will be disabled. This feature offers increased protection against improper use.
The execution of a command is accompanied by corresponding changes in the display field. If a disabled button is pressed, no change is shown on the display.
The control panel cannot be separated from the unit. If you are using it in combination with the OS3 VC830100 base unit, a VE830020 remote controller can be attached.
2.1 Arrangement of control and indicator elements
Diplay and setting area
Function selection area
Injection pressure indicator
Displays the selected limit value (current value flashes when active) of the injection pressure at the VISCO (B) outlet. The unit of measurement can be set using ParaProg (mmHg, PSI, kPa).
Extraction vacuum indicator
Displays the selected limit value (current value flashes when active) of the extraction vacuum at the VISCO (B) outlet. The unit of measurement can be set using ParaProg (mmHg, PSI, kPa).
Arrow buttons
The arrow buttons can be used to reduce (down arrow) or increase (up arrow) the value shown in the display field immediately above. Exert normal pressure to change the value slowly or in individual increments, or fully depress for rapid value setting.
The function selection area
AIR1 button and indicator light
Activates the AIR function with the pressure value stored in memory 1. The indicator lamp lights up. Press again to activate the pump and reduce pressure. Pressing once more will deactivate the pump and the function and switch off the indicator lamp.
The control and indicator elements are grouped in such a way that they can be operated after only a short period of familiarisation, even in semi-darkness. The top half of the control panel is the indicator and setting area. It is designed to show at a glance the operating state of the unit and the current values. The values displayed can be increased or reduced using the dark green arrow buttons directly below the value displays. The lower half of the control panel houses the function selection buttons.
Please familiarise yourself thoroughly with this ergonomic arrangement of the control elements; it will enable you to operate the equipment quickly almost "blind"!
The display and setting area
Air pressure indicator Injection pressure Extraction vacuum
indicator Indicator
Air pressure indicator
Displays the selected limit value (current value flashes when active) of the air pressure at the AIR (A) outlet. The unit of measurement can be set using ParaProg (mmHg, PSI, kPa).
AIR2 button and indicator light
Activates the AIR function with the pressure value stored in memory 2. The indicator lamp lights up. Press again to activate the pump and reduce pressure. Pressing once more will deactivate the pump and the function and switch off the indicator lamp.
AIR3 button and indicator light
Activates the AIR function with the pressure value stored in memory 3. The indicator lamp lights up. Press again to activate the pump and reduce pressure. Pressing once more will deactivate the pump and the function and switch off the indicator lamp.
INJCT button
Activates the Visco injection function with the limit value last used for the injection pressure. Press again to switch off the function.
EXTR button
Activates the Visco extraction function with the limit value last used for the extraction vacuum. Press again to switch off the function.
IOP button and indicator light
Enables the control of AIR functions via a duallinear pedal (illuminated display) when operated in combination with the OS3 VC830100 base unit When the unit is operated in stand-alone mode this button has no function.
29.05.09 VV016031E 4