ODM DLS 360 Device Manual And Quick-start Manual

DLS 360 Dual Laser Source
Device Manual and Quick-Start Guide
The DLS 360 dual laser source is a singlemode test laser used for verifying the proper
function of ber optic networks. This document will serve as an overview of the major features and functions of the device and will oer tips for troubleshooting common issues in optical networks.
Device Overview
1
The DLS 360 comes with an SC screw-on adapter. Additional adapters are available from ODM; see page 4 of this document for more information.
2. Wavelength Indicator
This unit oers 1490nm and 1625nm wavelengths. When the DLS 360 is turned on, the red light indicates which wavelength is selected. The red light will blink to indicate when the 2kHz modulation is turned ON.
3. Low Battery Indicator
A red indicator light will appear when the CR2 battery power is low. Replace the battery to return to normal operation of the DLS 360.
4. Power Button
Press this button to turn the DLS 360 ON and OFF. The unit will turn o automatically after 15 minutes. To bypass the auto-shuto, hold the power button for 5 seconds when turning ON.
5. 2kHz Button
Toggles 2kHz modulation of currently-selected wavelength output. Laser ashes at 2000 times per second to provide a recognizable signal to a companion power meter. Output power of the laser is reduced by 3dB when the modulation is active.
6. Wavelength Button
Switches between the 1490nm and 1625nm wavelength.
7. External Power Port
Accepts AC 030 power supply. Power supply is not a battery charger, just battery bypass.
3
2
4
6
5
7
M-UM009-01 Page 1
Caution: Invisible Laser Radiation
Please note that 1490nm and 1625nm wavelengths are not visible to the human eye. Do not look directly into the output port of the DLS 360 or directly into any ber connector that may be live.
Since the laser is invisible to the eye, the eye’s natural blink reex is suppressed. This can cause damage to the retina.
FDA 21 CFR 1040.10 and 1040.11
IEC 60825-1: 2007-03
Class 1 Laser Product
Transmitting Light
The DLS 360 transmits either the 1490nm or 1625nm wavelength on singlemode ber. Be sure to use a test jumper to mate the DLS 360 to the ber under test.
Mate Connectors Appropriately
Signal Propagates Down Fiber
Test Jumper
Output Power
The DLS 360 is calibrated to have an output power level of -5dBm. Variations in power level between -5dBm and -8dBm may be normal depending on the quality and age of the test jumper, the DLS 360 output port, and other factors.
Always ensure the DLS 360 is transmitting an acceptable power level before performing an insertion loss test. Simply insert the test jumper (plugged into the DLS 360) into a companion power meter set to the dBm mode. The power meter will indicate the measured output power of the laser.
Test Jumper Plugged
Into Power Meter
M-UM009-01 Page 2
Power Meter Displays Output Power of Laser