Ocean Blue OBLU1013 Owner Manual

Page 1
1
VACUUM CLEANER
USER’S MANUAL
Page 2
2
WELCOME
Dear Customer:
Thank you for your confidence in our product. It is our goal to bring you into the clean world of OceanBlue. If you have been using a “Conventional” cleaning system for dirt removal you might be in for a surprise!
If you find that you are having to empty the water pan more often than you think that you should, be
aware that, in the beginning, you are picking up more dirt because of the deep dirt that is in your carpets that was not removed before. After using the OceanBlue for a short time in regular use, you should find that the amount of dirt will taper off to more “normal” expectations.
You should be aware that deep dirt is the enemy of carpets. The deep dirt left in the carpet acts like little knives and slowly cuts the tufts of the carpets at the bottom as you walk on the carpet. You may see a
lot of “fuzz” coming up from the carpet in the beginning, but by removing this deep dirt, you are
increasing the life of your carpet.
Remember that the OceanBlue filtration system does not clog up the airflow as you use it. You still have
full power right up to when to empty the water pan.
TABLE OF CONTENTS
Index ........................................................................................................................... 2 - 3
Optional Accessories………………………………………………………………………………………………..3
Technical Specifications .............................................................................................. 4
Get to Know the Parts of Your OceanBlue Vacuum Cleaner .......................................... 5
Important Safety Instructions ........................................................................................ 6
General Precautions and Recommendations ................................................................ 7
Precautions when Vacuuming Liquids .......................................................................... 7
Special Care and Safety Instructions ............................................................................ 8
Servicing of Double Insulated Appliances .................................................................... 8
HydroTurbine Care…………………………………………………………………………………………………… 9 Operation and Handling……………………………………………………………………………………………. 10 Water container/HydroTurbine………………………………………………………………………………… 11
Using the attachments…………………………………………………………………………………...... 12
Hose…………………………………………………………………………………………………………………… 13
Page 3
3
Using your Vacuum…………………………………………………………………………………………….. 14
Warranty …………………………………………………………………………………………………………….. 15
Troubleshoot ……………………………………………………………………………………………………… 16 For Service and Repair ……………………………………………………………………………………………. 17
OPTIONAL ACCESSORIES
Prolux Storm: The Prolux Storm has incorporated an electronically driven brush roll to this
universal shampoo system. This design allows the shampoo system to agitate the surface which improves cleaning ability exponentially. This model works just like your regular power nozzle does, so all you must do is fill it up, and vacuum like you normally would.
Offers much higher power output than other shampooers on the market and offers self-adjusting brush roll height so you can easily move between surfaces. The self-adjusting design is exceptionally convenient when using on tile because it allows the brush roll to drop into and scrub grouted areas.
OceanBlue Water Based Air Purifier: This works as a humidifier, deodorizer, purifier,
aromatherapy and fragrance machine. For aromatherapy or to use as an air freshener, add a few drops of fragrance into the water bowl and turn on.
This OceanBlue also works as an humidifier by pushing moisture into the air and leaving the impurities behind in the water bowl to be disposed of. The best park is that this purifier does not over dispense moisture, so you will never have to worry about water left behind and is safe to use in any area!
Stair Pro Electric Mini Turbo: Quick
connect button lock to attach to your wand or vacuum handle. Brush roll is powered by durable electric motor and a geared belt that will last the lifetime of the tool. If you have pet hair you need to vacuum up this is a must! Not only do they last for many years but they deep clean better than almost anything!
Page 4
4
TECHNICAL SPECIFICATIONS
Major Housing Components: ABS plastic, min. thickness 3mm. UL flammability rating:
UL94-HB. Water pan: Top, ABS; bottom, copolyester.
Agency recognition: UL fi le number E-303875
Electrical characteristics:
120 volt
Amp, max, 7.6
Watt, max, 846
RPM, working, 17,300
Sealed vacuum, 68”
CFM, working, 56.8
CFM, max, 98
Nano Silver Tech
Motor rating, Class A
Basic machine weight: 6.4 Kg (no water); 8.0 Kg (w/water)
Page 5
5
GETTING TO KNOW THE PARTS
1. Power Button 16. Suction Relief Valve
2. Hose/Cord Hanger 17. Tool Hose/Wet Pickup
3. Blower Output on Back 18. Mini Turbo w/Spinning Brush roll
4. Water Bowl Latch 19. Handheld Shampoo
5. Friction Fit Caddy (Also Holds Tools) 20. Blower/Coil Cleaner
6. Water Basin 21. 32 mm Tool Kit
7. Power Hose Plug
8. Electric Main Hose
9. Power Head Switch
10. Handle Release
11. Extendable Wand Button
12. Wand Release Pedal
13. Electric Power Nozzle
14. Rubber Bumper
15. Pivot Release
Page 6
6
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following: READ
ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WARNING: To reduce the risk of fire,
electric shock, or injury:
1. The switch used for controlling the appliance must be pushed to start and pushed to stop.
2. This appliance is for indoor use only. Do not store in wet places.
3. This appliance is for household use only.
4. DO NOT let children use the OceanBlue without adult supervision. This appliance is not a toy.
5. DO NOT leave appliance unattended when plugged in. Unplug from outlet when not in use and before
emptying the water container.
6. USE ONLY as described in this manual. Use only manufacturer’s recommended attachments.
7. DO NOT use with damaged cord or plug. If appliance is not working as it should, has been dropped,
damaged, left outdoors, or dropped into water, return it to a service center.
8. DO NOT pull or carry by the cord, use cord as a handle, close a door on cord, or pull cord around sharp
edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
9. DO NOT unplug by pulling on cord. To unplug, grasp the plug, not the cord.
10. DO NOT handle plug or appliance with wet hands.
11. DO NOT put any objects into openings. Do not use with any opening blocked; keep free of dust, lint, hair
and anything that may reduce air flow.
12. KEEP HAIR, loose clothing, fingers, and all parts of body away from openings and moving parts.
13. USE EXTRA care when cleaning on stairs.
14. NEVER use to pick up flammable or combustible liquids such as gasoline or use in areas where they may
be present. See section PRECAUTIONS WHEN VACUUMING LIQUIDS.
15. ALWAYS turn off this appliance before connecting or disconnecting either hose or motorized nozzle
(optional).
16. TURN OFF all controls before unplugging.
17. This appliance is provided with DOUBLE INSULATION. Use only identical replacement parts. See instructions for SERVICING OF DOUBLE INSULATED APPLIANCES.
18. DO NOT pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
19. Before turning on this appliance, make sure the machine is tightly secured by the clamps to the water container. Failure to do this could cause a risk of injury to persons and would defeat the utility of the appliance.
20. Your OceanBlue is provided with a safety interlock switch to prevent operating the appliance without attaching the water container to the appliance. Because the turbine operates at high speed, this is to protect you from coming into contact with the moving HydroTurbine.
Page 7
7
GENERAL PRECAUTIONS & RECOMMENDATIONS
IMPORTANT
Please read all instructions before using this machine and keep this manual always at hand.
Follow the instructions manual for the Ocean Blue‘s. Do not try to use it otherwise. The use of
non-authorized accessories by OceanBlue could be dangerous. See section SERVICING OF DOUBLE INSULATED APPLIANCES.
DO NOT plug the OceanBlue into the receptacle of an incandescent light bulb, nor use extensions cords with less electrical capacity than needed.
The OceanBlue must not be used to clear sewers. An explosion may occur if the machine suctions sewer gases.
You must NEVER touch a metallic kitchen sink or washbasin or water pipelines with one hand while holding the machine with the other hand. The danger is greater if the
person’s skin is wet.
Take special care when cleaning stairs.
ATTENTION: It is not recommended to use the OceanBlue for cleaning chimneys or open stoves, or other devices that have oil or grease, for example, soot or ashes, clay dust, plaster or other similar materials that are resistant to water action. It must not be used for vacuuming toxic or volatile substances or near any of these.
PRECAUTIONS WHEN VACUUMING LIQUIDS
Always consider the following precautions:
DO NOT operate the machine with wet hands or feet or barefoot.
NEVER use OceanBlue to clean up liquids outdoors, upon an earth floor.
NEVER vacuum liquids with OceanBlue when you are stepping on water or a wet floor. If it should be necessary to step on a wet or damp floor to pick up water, do not touch the metallic parts of ANY electric device, lamp or switch while performing this operation.
DO NOT carry the machine with your hand while using the machine for cleaning operations.
The water container must be empty before you begin picking up liquids. DO NOT vacuum more than 1.9 liters (2 quarts); the water level MUST NEVER be above the central post. Excess water in the water container will cause shaking and vibration. If this occurs, the vibrations are your warning that the water container is overfilled. (If you have a need to pick up more than 2.5 liters of water frequently, consider the optional 4­liter water container shown on page 18.)
Page 8
8
SPECIAL CARE & SAFETY INSTRUCTIONS
WATER: Do not operate the OceanBlue for too long without changing the water. When
you notice that the water is getting too full of dust and fuzz, throw it away and replace it with clean water. The correct level of water is that of the height of the central post of the water container.
WATER CONTAINER: When you finish cleaning your house, be careful to put away the OceanBlue‘s motor apart from the water container between uses. ALWAYS empty the water container after each use.
THE HYDROTURBINE IS THE HEART OF YOUR MACHINE Unplug the OceanBlue from the power outlet. Remove and clean the HydroTurbine after each use. Wash it inside and out with water and soap, using the brush provided. Dry it and put in place again. Tighten the nut by hand until the fl at surface of the HydroTurbine is properly adjusted. Do not over tighten, as the HydroTurbine automatically tightens upon starting the machine. The HydroTurbine
is the key for separating the dirty water from the airflow and proper
care is important for the performance of your appliance. If the HydroTurbine should become damaged (CHIPPED OR BROKEN), replace the HydroTurbine with a factory made turbine from your Service Center. WARNING: The OceanBlue must NEVER be used without the HydroTurbine. Always place it back after cleaning it.
SERVICING OF DOUBLE INSULATED APPLIANCES: For your safety and protection, your OceanBlue is a DOUBLE INSULATED appliance. NEVER attempt service on the electrical parts of the appliance EXCEPT at your OceanBlue Service Center. There are special requirements for servicing DOUBLE INSULATED appliances. Failure to do so can cause safety hazards with your unit.
Page 9
9
HYDROTURBINE CARE
Page 10
10
OPERATION AND HANDLING
General guidelines for using OceanBlue:
Fill up the water container with cold water until it almost covers the top of the central post:
correct quantity of water 2.365 liters (2.5 quarts). (fig.1) The motor unit is placed on top of the water container (fi g.2). The air intake should be lined up
with the notch in the motor unit. The edge of the motor unit should be firmly rest on the top of
the water container and be inside of the retaining ring for correct location, otherwise, the machine will not work. Engage the two clamps and raise the upper part of the clamps together. Place the machine on top of the wheeled base. Note: The clamps will not operate properly if
the motor unit is not in the proper position on the water container. If the clamps do not operate easily, check the location of the motor unit.
Insert the plastic wand into the curved wand with the OceanBlue hose (fi g.3) until the button fits in place. Insert the plastic end of the OceanBlue hose into the vacuum air intake as shown (fi g.4), rotating it to right. To disconnect, rotate it to the left and pull it towards you.
Page 11
11
WATER CONTAINER / HYDROTURBINE
To empty the water container:
1. Release both clamps by pulling the upper part of the clamp assembly down and remove motor.
2. Pickup the water container by the vacuum intake end and empty the water.
3. Place the heavier particles in the bottom of the water container in a trash can (such as wet fuzz)
4. Wash, rinse and dry the water container
5. Keep the motor apart from the water container until next use.
Care of HydroTurbine:
Take out the turbine after each use and wash it inside and out with water and soap, using the special supplied tool. Dry it and put it back in its place. Tighten the nut by hand until the turbine is seated and the rim is flush with the rim of the metal casting of the motor. Do not over tighten, as the HydroTurbine automatically tightens up on starting the machine.
WARNING: The HydroTurbine must always be positioned back in its place immediately after you clean it. Do not operate the machine without the HydroTurbine.
Page 12
12
Using The Attachments
Floor Tool (Fig 1): Soft natural fill which supports the brush over hard floors and makes it
easily maneuverable over uneven surfaces, without damaging the finish. It has wide cleaning opening which captures large debris and delivers effective cleaning power to the far edges of the tool.
Duster Brush (Fig 2): The Dusting Brush is used for all types of furniture.
Crevice Tool (Fig 3): Use for cleaning radiators, cracks & crevices along corners, and
baseboards and in-between cushions.
Upholstery Tool (Fig 4): Designed to clean the dirt that becomes embedded in your
furniture and limits the life of the fabric. The tool also comes with slide on bristles, so you can use it on hard furniture, dusting or to add a more aggressive surface to your tool which can help in removing pet hair that is entangled in your fabric.
Mini Turbo (Fig 5): This is the best pet hair tool in the business! Perfect tool for upholstery,
stairs and hard to reach places. This is the deluxe model with a geared belt which reduces slippage and increases the life of your tool. Brush roll is designed to sweep debris to middle of head for easy pick up. The swiveling bottom plate allows you to use this on your floors as well. Fits nearly any standard vacuum.
HandHeld Shampooer (Fig 6): This attachment
works great for those small areas that your regular sized shampooer system is just too big for. Works great in the car, on rugs, throw pillows, and furniture.
Blower/Coil Cleaner (Fig 7): This attachment is
a high end tool that works great for cleaning hard to reach areas. The bristle attachment makes it especially easy to reach under washer/dryer, behind your fridge and even in your vents! This tool also works great as an inflator and detailing blower on vacuums with blower option.
Page 13
13
HOSE
Use to vacuum dry and wet materials on floor, walls, tapestries, electro-domestic devices, air conditioning ducts, clothes, etc.
To clean and/or to dry the interior of the hose and of the stainless curved wand:
1. Remove the discharge air cover of the OceanBlue
vacuum cleaner and introduce the plastic end of the hose in it as shown.
2. Then connect the other end of the hose into the
vacuum air intake. Turn on the motor and shake the hose. Any stuck material in the interior of the hose will be suctioned and submerged into the water container; OceanBlue’s hose will also become completely dry, after vacuuming water.
3. This procedure can also be used before using your
OceanBlue hose for any blowing operation.
Page 14
14
USING YOUR VACUUM
REMEMBER THE FOLLOWING WHEN USING YOUR VACUUM CLEANER:
The functioning of your new cleaning equipment greatly depends on the maintenance given at home. Only use your OceanBlue equipment according to the instructions provided in this manual.
Before using the machine pick up by hand any hard or sharp objects such as pins,
hairpins, thumbtacks, pieces of pencil, etc. that could harm the spinning brush roll.
Do not lubricate the motor. The motor has permanent lubrication and is sealed.
Shut down the machine before connecting hose.
Do not use the machine to clean chimneys, open stoves, or other materials containing
oils, grease, soot, ashes, clay dust, plaster or other water-resistant materials.
It must not be used either to vacuum volatile or toxic substances, nor to be operated
near them.
SERVICING OF DOUBLE-INSULATED APPLICANCES
A double-insulated appliance is marked with one or more of the following: The words
“DOUBLE INSULATION” or “DOUBLE INSULATED” or the double insulation symbol
(square within a square) .
In a double-insulated appliance, two systems of insulation are provided instead
of grounding. No grounding means its provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing a double-insulated appliance requires extreme care and knowledge of the system and should be done only by qualified service personnel.
Replacement parts for a double-insulated appliance must be identical to the
parts they replace.
All service operations, other than cleaning, must be done by an authorized service agent of OceanBlue.
Page 15
15
FIVE (5) YEAR LIMITED WARRANTY
(90 days on the motor and body if used commercially)
Prolux warranties this product’s motor free from defects in material and workmanship for a period of five (5) years on the motor, and two (2) year bumper-to-bumper limited warranty on the body of the vacuum, free from manufacturer defects in material and workmanship from the original date of purchase, when utilized for normal household use.
(90 days on the motor and body if used commercially)
Subject to the following conditions, exclusions, and exceptions:
What is Not Covered by the Prolux Warranty - Warranty Exclusions. This limited warranty does not extend to and expressly excludes:
1. Normal wear and tear and/or replacement attachments or accessories, including, without limitation, extension cords, hoses, filters, switches, carbon motor brushes and other attachments to the Backpacks.
2. Damage or burnout of the Backpack or Canister motor resulting from failure to clear a blockage occurring during the normal course of use.
3. Loss or damage to the Backpack or Canister resulting from conditions beyond the control of Prolux including without limitation, misuse, accidents, abuse, neglect, negligence from the customer, overuse beyond capacity of the vacuum, or unauthorized modification and/or alteration.
4. Loss or damage to the Backpack or Canister resulting from failure to follow the required maintenance schedule, or failure to use the Backpack or canister in accordance with written instructions from Prolux, guidelines or the terms of its Owner’s Manual.
If your appliance fails to operate properly while in use under normal household conditions within the warranty period, please contact your authorized PROLUX dealer you purchased the unit from. Non­durable parts including, without limitation, filters, accessories, brushes, belts, and electrical parts, which normally require replacement, are specifically excluded from warranty.
This warranty is limited solely to the cost of the repair or replacement of the unit at Prolux’s option. This
warranty does not cover normal wear of parts and does not apply to any unit that has been tampered (by unauthorized user) with or used for commercial purposes. This limited warranty does not cover damage caused by shipping damage, misuse, abuse, negligent handling, or damage due to faulty packaging or mishandling in transit.
This warranty is extended to the original purchaser of the unit only and is not transferable.
*IMPORTANT: Before sending unit back for warranty work, contact your authorized PROLUX retailer you bought the unit from first. Unauthorized warranty claims may be sent back.
Authorized Warranty claims: PROLUX shall be responsible for all parts and labor and the customer shall be responsible for all shipping charges to and from the PROLUX service center.
Prolux is constantly striving to improve our products. Therefore, the specifications contained herein are subject to change without notice.
Page 16
16
Troubleshooting
WARNING: Never use a defective appliance. Always switch off the appliance and disconnect it from the
outlet or remove the battery before you start to troubleshoot.
Fault
Possible Cause(s)
Solution
The vacuum will not turn on.
The plug is not connected to the electrical wall outlet or the appliance is not switched to the on” position.
Insert the plug into an electrical wall outlet and flip the “on/off” switch to the “on” position. See section “Vacuum Cleaning.”
Electrical wall socket does not carry current.
Test the vacuum cleaner on another outlet that you are sure is carrying current.
The power cord is damaged.
Replace with a new cord by an authorized service center or professional technician.
Suction power is low.
The water basin is full or clogged.
Empty/clean the water basin.
The power nozzle, attachment wand or suction hose is clogged.
Remove the debris that is causing the clog. If necessary, use a long wooden stick (e.g. a broomstick) or coat hanger to do this.
The water basin container is installed incorrectly.
Remove water basin container and reinstall; making sure the container is locked into place when reinstalling.
The tool attachment being used, does not work properly on the surface you are vacuuming.
Attach the appropriate tool for the surface you are vacuuming. See pages 8-9.
The vacuum makes unusual noises or is louder than usual.
The power nozzle, attachment wand, or the suction hose are clogged.
Remove any clogs. If necessary, use a long wooden stick (e.g. a broomstick) or coat hanger to do this.
Page 17
17
FOR SERVICE AND REPAIRS
To locate a dealer in your area, call 1-800-619-1006
Please visit www.oceanblue.com for complete warranty information.
DEALER
STICKER
HERE
Loading...