STANDARD FEATURES
CABINET
The OWC-Series cabinet is constructed of 18 gauge steel with a gray polyester powder coated
finish that will compliment any decor. The entire cabinet is insulated with sound- absorbing
insulation for cool, quiet comfort. All units come equipped with swivel casters for portability
and convenient set-up.
DELUXE ELECTRONIC CONTROLLER
All OWC units are equipped with a deluxe electronic controller. When power is connected to
the unit, the thermostat will control the unit to cool a space to the desired temperature. The
thermostat is also capable of controlling the fan to operate automatically (when needed), or
continuously. To protect the compressor from short-cycling, there is a built-in time delay in the
thermostat. In the event of a power outage, all thermostat settings are saved, and the unit will
re-start automatically.
FAN SPEED CONTROL
The deluxe electronic controller is capable of setting fan speeds automatically or manually. In
AUTO mode, the fan speed adjusts in accordance to cooling conditions. In MANUAL mode,
the fan speed can be maintained at any one of six speed levels, from low to high.
CONDITION ALARM—CON
The LED thermostat of the OWC will display the word “CON”. CON indicates a fault
condition that needs to be addressed:
CONDENSATE PUMP...disabled / restricted drain tube/routed incorrectly
WATER SUPPLY……….turned off / interrupted flow
EITHER CONDITION WILL TRIP THE HIGH PRESSURE SAFETY SWITCH. See below.
CONDENSATE PUMP
All OWC units come equipped with an Automatic Condensate Pump that removes the
condensate. The pump discharges through a 3/8 male flare DRAIN connection located on the
back of the unit. The pump is capable of pumping to a 20-foot height, to handle almost any
installation requirement.
HIGH PRESSURE (HP) SWITCH
Located on the back of the OWC unit is a manual re-set high pressure switch, used for the
protection of the compressor in the event that the condenser water supply is turned off. If the
condensing pressure exceeds the limit setting, the switch cycles off the compressor, while the
evaporator fan remains running, and the default “CON” will display on the controller. The high
pressure switch is also wired in series with the condensate pump. If a failure occurs with the
operation of the pump circuit, the HP switch will open. Once the water interruption/condensate
pump failure has been corrected, turn the unit off, reset the switch by depressing the red
RESET button on the back of the unit, and restart the unit.
FILTERS
All OWC units are equipped with a washable filter at the air intake. An electrostatic mesh air
filter is located behind the evaporator return air grille to filter the air before it is cooled,
keeping the coil free from dust build-up. The filter can be easily removed and cleaned.
POWER CORDS
All OWC units come standard with a power cord for a convenient connection. All
models, except for the 3-phase units and 5-ton units, are equipped with LCDI for
added safety features.
3