OceanAire 2OACH1211 User Manual

ACCESSORY
INSTALLATION
INSTRUCTIONS
Unplug unit. Open lower front door to expose con-
densate bucket. Remove bucket.
QuicltConnect Condensate Pump
AU 20AC/OACH AIR COOLED UNITS
The Quick Connect Condensate Pump may be easily instaIled for one job, and just as easily reinstaIl the bucket for the next job. Our quick connect kit consists of our speciaIly prepared and wired condensate pump, 20 feet of 3/8 plastic tubing, 2-10 inch pieces of 3/8 drain hose, 3
hose clamps, 2 plastic bushings and 2 attaching screws.
Cushion mounting
TOOLS REQUIRED:
Phillips screwdriver
pad
2) Start the ftrst pump bracket mounting ~crew into the second hole located on
the left side of the bucket tray. Just turn the screw enough to catch a few threads.
Later you will slide the bracket under it.
June 1, 2003
Line voltage molex plug (for pump motor)
3a) There is a second drain line from the rear coil on all heat pump models.
Use a 10 inch piece of hose (1 of 2 supplied)' and push the drain hose over the barbed fitting
Pictured 20AC Cooling Only
7) Remove electrical tape covering pre-wired line voltage molex plug. This plug is located on the wiring harness above the condensate pump
8) Push large molex plug from the pump, into the pre-wired receptacle.
as shown. No hose clamp is required. Route the other end into the condensate pump tank. [1' this line is removed in the future, slit the plastic drain hose over the barb to release the pressure fit tension. It will then be easy to remove.
4) Slide the left side pump mounting bracket under the screw started in step I. InstaIl the right side pump bracket mounting screw into the predrilled hole on the bucket tray. Tighten both screws firmly, but do not over tighten.
Attach 10 inch piece 00/8 drain hose to condensate drain using hose clamp sup- plied. Route other end of hose into con- densate pump tank.
HEAT PUMP ONLY
Pictured 20ACH Heating Cooling
5) Using the Phillips screw driver, re-
move the right side panel (viewed from the front of the unit) and remove the
plastic knock-out plug as pictured.
6) From the outside of the unit, route the drain hose into the unit through the hole. Continue ,through the partition panel bushing, located above the compressor. Remove or cut through the foam tape to reveal the bushing. PuIl the drain through the partition and ~ttach it to the pump discharge fitting as
shown. Re-attach side panel.
9) Disconnect molex plug from the low voltage
micro switch that was used by the bucket.
1-866-6fT-AlRf (438-2473)
10) Push the low voltage.
molex from the pump into the pre wired molex receptacle.
Installation complete
quickconnectcondsatepwnp