ARCTICAIRE and CONVERTIBLEAIRE SERIES Portable Air-Cooled Air Conditioners and heat
pumps are designed to cool or heat an entire area by discharging air through their 12 x 5 grille (Models
2OAC12 and 2OACH12) 14 x 8 1/2 (Models 2OAC/2OACH18, 24), 18 X 10 (Model 2OAC/
OACH36) and 18 x 12 (Models 2OAC/2OACH60). These self contained units are also designed to
direct air to specific areas or objects through (optional) dual 4 in. diameter nozzles (Model
2OAC/2OACH12) and 6 in. diameter nozzles (Models 2OAC/2OACH18, 24 ,36), and 8 in. diameter
nozzles (2OAC/2OACH60). The cord connected Models range from 13,500 to 60,000 BTU/HR cooling
and from 11,685 to 53,445 BTU/HR heating. Floor mount configuration can satisfy most space
requirements. All models are provided with casters for portability.
These models are thoroughly self-contained with the entire refrigeration system, evaporator and
condenser fan motors and electrical components neatly arranged in a gloss grey and blue texture
polyester powder coated metal cabinet. Only power, and an opening to dispose of condenser hot air is
required. The 24 volt solid state electronic controller provides the desired comfort level. The cordconnected model units are provided with heavy-duty, swivel casters for easy handling and convenient
relocation.
GENERAL REQUIREMENTS
IMPORTANT - ArcticAire and ConvertibleAire Air Conditioners and Heat Pumps are designed
and engineered for the comfort of the end user. The length of service received can be extended by
following the installation and preventive maintenance instructions. It is important that the warranty card
be filled out completely and returned to the factory within fourteen (14) days of installation of the unit
in order to receive the benefits of the warranty.
Condenser Motor HP 1/14 1/8 1/5 1/2 1/2 3/4 3/4 3/4
Condenser Motor Watts 59 106 160 365 365 570 570 570
Condensate Pump Head
20 Feet
Pump Optional on these units
Pump Standard on 5-Ton
Sound Level6 Hi/Low 56/54 61/60 64/62
R-22 Charge Oz. 29 36 40
Height with Casters 36 1/2
Height without Casters 32 1/2
Width 20
Depth 25
44 1/2
39 1/2 44 48
24
30
45 77
48 1/252 1/2
28
35
66/64 65/63
39
Net Weight 180 245 230 350 350470470490
Shipping Weight 200 285 260 390 390520520550
Shipping Volume 18 34 34 37 37404040
Cooling Capacity Total 95° F at 60% RH
Outdoor high fan speed.
Amps & Watts at 208 Volts
CFM with free discharge Hi/Low fan speed
Time delay fuses/circuit breakers are recommended
EER determined with condenser discharge air ducted into another area on high fan speed
Sound pressure, dB at 5 feet, commercial configuration (ducted condenser air), hi/low
evaporator fan speed.
Electrical ratings per U.L 484 at 95°F DB/75°WB on high fan speed
4
Ambient operating range 65° to 105°
May operate to 55° if equipped with optional factory
Installed hot gas bypass
Specifications subject to change without notice.
STANDARD FEATURES
SERVICEABILITY
All 2OAC/OACH Series units are designed with quick connect removable side panels to provide full
service accessibility. Only one screw needs to be removed for access to the inside of the unit. Turn to
page 17 “Part Replacement Procedure” for removal of the correct panel when replacing a part. The
interior is divided into two sections, front and rear. The front section contains the evaporator blower, coil,
condensate bucket and thermostat. The rear section contains the condenser blower, coil, compressor,
electrical control box and cord storage box.
ATTRACTIVE CABINET
The 2OAC/OACH Series cabinet is constructed of 18 gauge cold rolled steel with a gloss grey and blue
texture polyester powder coated finish that will compliment any decor. The entire cabinet is insulated
with a sound absorbant insulation for cool, quiet comfort.
HIGH PRESSURE SAFETY SWITCH
All units incorporate a manual re-set high pressure switch for maximum protection of the refrigeration
system and compressor. The cut-out pressure setting is 375 ±5 psig or 425 ±5 psig. If the pressure
exceeds this setting, the compressor stops and can be re-started by depressing the “RESET” button
located on the back panel of the unit. The high pressure control’s capillary line is attached to a schrader
valve. This allows replacement of a defective control without recovering the refrigerant.
Condenser Motor
Condenser Coil
Control Box
Kick Plate
Casters
Evaporator Motor
Evaporator Coil
Condensate Tank
Condensate Tank Tray
Water Level Detection
Control
5
STATE-OF-THE-ART CONTROL SYSTEM
This self diagnostic control system handles more than just temperature. The ConvertibleAire (2OACH)
has automatic changeover from heating to cooling and cooling to heating. The ArcticAire (2OAC) does
not since it is a cooling only model. The temperature setpoint range is from 55°F to 85°F.
A built-in time delay prevents compressor short cycling.
The built-in 6 speed fan controller decreases the fan speed as the temperature approaches the setpoint.
The LED display will read the return and supply air temperature...as well as setpoint.
MOISTURE MODE
When entering the moisture mode with the select button the fan will start within 1 minute at speed level 3.
The fan will run for 30 minutes sampling the air temperature and storing it into memory. If the ambient
air temperature is above 60°F, the compressor will then start. The compressor will run for a maximum of
one (1) hour, or until there is a 2°F drop in ambient temperature. After the compressor shuts off, the
evaporator fan will continue to run for four (4) more minutes, then turn off. This cycle will start again in
four (4) hours. The right most decimal is lit while the compressor is running. If the unit is properly sized
for the conditioned space, this process should maintain the relative humidity between 50-60%.
FILTERS
The condenser coil filter is 1/4 inch thick washable foam located in the filter grille assembly in the back
of the unit. The evaporator filter is 1/4 inch thick washable foam located in the filter grille assembly in the
front of the unit. To remove filter: (1) lift and pull out the filter grille. (2) pull the filter away from the
velcro attaching strip. (3) wash, and re-install in reverse order. The filter may be reinstalled damp since
the air flow will dry it quickly.
SERVICE CORD
All ArcticAire (2OAC) and ConvertibleAire (2OACH) Series units are equipped with a standard ten (10)
foot long service cord with plug configurations and receptacle requirements as shown in the chart below.
UNIT MODEL PLUG CONFIGURATION RECEPTACLE
2OAC12 / 2OACH12
2OAC18 / 2OACH18
115 V
2OAC24
2OACH24
208/230 V
2OAC36
2OACH36
208/230
2OAC60
2OACH60
208/230
2OAC6032
2OACH6032
208/230/3
2OAC/OACH3634
460 3 PHASE
50A-250V NEMA 6-50P
NEMA L14-30P
15A-125V
NEMA 5-15P
20A-250V
NEMA 6-20P
30A-250V
NEMA 6-30P
30A-250V
20A-460 VOLT
NEMA 5-15R
NEMA 6-20R
NEMA 6-30R
NEMA 6-50R
NEMA L14-30R
NEMA L16-20R
NEMA L16-20P
2OAC/OACH6034
460 3 PHASE
30A-460 VOLT
NEMA L16-30R
NEMA L-16-30P
6
CONDENSATE RESERVOIR TANK
ArcticAire (2OAC) and ConvertibleAire (2OACH) utilize a 5.0 gallon capacity, polyethylene condensate
drain tank, located in the lower, front section of the unit behind the tank door. A high water level cut-out
switch is used to stop the compressor and condenser fan automatically when the tank's pre-set water level
has been reached. The evaporator fan will continue to run, circulating air.
An adjustment screw is provided to vary the cut-off of the tank full switch. If a lighter (less weight) level
of water is desired, turn the adjusting screw clockwise. Do not exceed 6 full turns clockwise.
CAUTION, TURN UNIT OFF:
BEFORE ADJUSTING SET SCREW
BEFORE REMOVING TANK TO EMPTY CONDENSATE
Condensate Tank
*Tank Water
Level Adjusting
Screw
Spring
High Water Level Cut-Out Switch
Condensate Tank Tray
Condensate Water
From Evap Coil
Water Outlet
Cap
Max Water Level 4"
Handle
Plug
Minimum
Water Level
1"
Base Pan
FRONT
* Turn screw clockwise to lower water level, which makes tank lighter in weight and easier to
handle.
NOTE: Max. and Min. water levels shown are those at which the unit will shutdown and not restart
until the condensate tank has been emptied.
7
OPTIONAL FEATURES
TREATED EVAPORATOR AND CONDENSER COILS
When airborne contaminants are a problem for air conditioning applications, acrylic and heresite coated
coils are recommended to guard against pitting and corrosion. Call factory for details.
CONDENSER DUCT
If a longer, 12" or 16" diameter duct is needed on the condenser discharge, 10 ft. flexible ducts may be
coupled or weaved together to your desired length. The following chart
Model
Ceiling Kit
CK-12
Size/Fits
CK-16
Size/Fits
Round Flexible
Duct Size Diameter
Length
12 inch
8 feet
16 Inch
8 feet
Fits
2OAC12
2OACH12
Yes Yes Yes
No No No
Fits
2OAC18-24
2OACH18-24
Fits
2OAC36
2OACH36
Fits
2OAC60
2OACH60
No
Yes
(add 6 feet for each 90° bend)
Maximum
Equivalent Feet
(ESP)
25
(.20)
40
(.25)
80
(.50)
80
(.50)
CEILING PANEL/DUCT KIT ASSEMBLY
A 12 inch diameter (Model 2OAC/2OACH12-18-24-36) and 16"
diameter (Model 2OAC/2OACH60) flexible duct kit assembly
extends to vent condenser air or to draw condenser return air
from the ceiling when a condenser return air plenum is used. It
comes with a 2' X 2' lay in ceiling panel/collar assembly for
venting into the plenum area above the false ceiling, plus a duct
collar to attach the duct to the unit. Installation can be completed
by following these simple steps:
1) Slip one end of the duct over the lay in ceiling panel/collar
assembly and the other over the unit duct
collar.
2) Clamp or screw duct to lay-in ceiling
panel/collar assembly and unit duct collar.
3) Place the 2' X 2' lay-in ceiling panel in
the false ceiling directly above the unit.
2x2 Lay-in ceiling panel
Flexible Duct
Duct Flange (attaches to
unit)
Duct flange provided on 3 and 5 ton units.
4) Screw duct collar to unit with three
screws provided.
8
DISCHARGE AIR NOZZLE KIT ASSEMBLY
The optional nozzles can be
easily attached to the unit
without tools to direct cold air
(or warm air with heat pump)
to a specific spot or area. The
chart below illustrates
application information for
each nozzle kit.
Model
Nozzles
2NK-1
2NK-2
2NK-3
Round Duct
Number/Diameter
Compressed Length
2 x 4 inch
15 inches
2 x 6 inch
22 inches
2 x 8 inch
20 inches
OPTIONAL CONDENSATE PUMP KIT
2NK-2
Approximate
Extended
Length
21 inches Yes No No No
32 inches No Yes Yes No
29 inches No No No Yes
2OAC12
2OACH12
2OAC18-24
2OACH18-24
2OAC36
2OACH36
2NK-3
2NK-1
2OAC60
2OACH60
A condensate pump kit designed as an automatic condensate removal system for water dripping off of the
evaporator coil is available. This pump kit can be used in place of the condensate collection tank, which is
standard on every model except the 5-ton, where a condensate pump is standard equipment.
It is a convenience for those who do not want to empty the 5.0 gallon condensate tank. It is very
convenient on units that are permanently installed.
This pump is capable of pumping against a 20 foot head and is controlled by a float/switch mechanism
which turns the pump "on" when approximately 2 1/2 inches of water collects in the tank and
automatically switches "off" when the tank drains to a level of approximately 1 1/4 inches. A built-in
pump safety switch turns off the air conditioner if the condensate line becomes plugged or pump motor
failure should occur. A built-in check valve prevents drain back and short cycling of the pump.
The pump kit includes tubing,
mounting bracket,
hardware , wi r i ng
and insulated
mounting base.
Pump kit installs in place
of the condensate bucket
located behind the door
Pump Kit
on the front of the unit.
9
The Quick Connect Condensate Pump may be
easily installed for one job, and just as easily
reinstall the bucket for the next job. Our quick
connect kit consists of our specially prepared
and wired condensate pump, 20 feet of 3/8
plastic tubing, 2-10 inch pieces of 3/8 drain
hose, 1 hose clamp, and 2 attaching screws.
7) Remove electrical tape covering pre-wired line voltage
molex plug. This plug is located on the wiring harness
above the condens ate pump
First hole
3)Attach 10 inch piece of 3/8 drain hose to
HEAT PUMP ONLY
3a) There is a second drain line from the rear
coil on all heat pump models.
Use a 10 inch piece of hose (1 of 2 supplied)
and push the drain hose over the barbed fitting
as shown. No hose clamp is required. Route the
other end into the condensate pump tank. If
this line is removed in the future, slit the plastic
drain hose over the barb to release the pressure
fit tension. It will then be easy to remove.
4) Slide the left side pump mounting bracket under the
screw started in step 1. Install the right side pump
bracket mounting screw into the predrilled hole on the
bucket tray. Tighten both screws firmly, but do not
over tighten.
Second hole
condensate drain using hose clamp
supplied. Route other end of hose into
condensate pump tank.
Low voltage molex
plug (for safety
switch)
Mounting brackets,
One on each side
Cushion mounting
pad
Line voltage molex plug
(for pump motor)
2) Start the first pump bracket mounting
screw into the second hole located on
the left side of the bucket tray. Just turn
the screw enough to catch a few threads.
Later you will slide the bracket under it.
Barbed fitting from rear coil
Pictured 2OACH Heating Cooling
5) Using the Phillips
screw driver,
remove the right
side panel (viewed
from the front of the
unit) and remove
the plastic knockout plug as pictured.
6) From the outside of the unit, route the drain
hose into the unit through the hole. Continue
through the partition panel bushing, located
above the compressor. Remove or cut
through the foam tape to reveal the bushing.
Pull the drain through the partition and
attach it to the pump discharge fitting as
shown. Re-attach side panel.
8) Push large
molex plug from
the pump, into
the pre-wired
receptacle.
10
9) Disconnect molex plug
from the low voltage
micro switch that was
used by the bucket.
10) Push the low voltage
molex from the pump
into the pre wired
molex receptacle.
Installation
complete