RFCCL AUTO ROTATING BLADE CLEAVER
Auto Rotating Blade Cleaver
Contact your OCC Representative at 1-800-622-7711 for Ordering Information
Instruction Manual
Safety Instruction and Cautions for Use
• Read this manual thoroughly before using Cleaver and always keep this manual with cleaver
• Use caution during use of Cleaver to prevent bodily harm to yourself or others.
Keep cleaver away from water.
Store cleaver away from humid and dusty
environments.
Operating Temperature 0 - 40°C.
Storage Temperature: -40 - 80°C.
Serious impact on the product can cause the product
malfunction.
To change cleaver blade, use the proper tools
provided and make sure the screws are tightened
properly.
Refer to connector instructions for proper strip and
cleave length.
Do not use acetone or solvents when cleaning the
cleaver.
RFCCL
1. Cleaver Assembly & Component Parts
Cleaver Body Instruction Manual
Carrying Case Hex Wrench(1.5mm)
Rotating Blade
Wrench
▲Bottom
Damper
Rack Gear
Slider Advance
Gear Advance
Release Pin
Holder Cover
Holder
Clamp Lower
Upper Cover
Clamp Upper
Blade Gear

RFCCL AUTO ROTATING BLADE CLEAVER
Auto Rotating Blade Cleaver
Contact your OCC Representative at 1-800-622-7711 for ordering information
2. Operation Procedure (Fiber Cleaving)
Open the upper cover (should
automatically open fiber holder
cover), and place the stripped
fiber on the cleaver holder.
Adjust fiber length using metric
scale per connector instructions.
Align fiber and close upper
cover.
3. Rotating Blade
To cleave push release button
down to rotate the blade
through gear advance. Fiber
fragment automatically pulls
into the scrap collector.
Open upper cover, carefully
remove cleaved fiber from
the holder.
①
On the blade gear, the channel (cleaving position) from 1 to 24 is marked. Blade height is set at factory, no adjustments
The blade gear rotates the blade after each cleave, blade is good for 50,000 cleaves.
② When it does not cleave the fiber properly, clean the surface of rubber pad with the alcohol-soaked cotton swab (caution,
do not use acetone or solvent to clean the rubber pad)
③ If cleaver still does not cleave properly, it means the blade is worn, cleaver must be returned to the factory for blade replacement
and height adjustment.
LC/SC Mechanical Splice Connector 250/900um:
Insert the fiber into the cleaver and stop at the
correct cleaving distance of 10mm for SC & LC
ST Mechanical Splice Connectors:
necessary.
LC/SC Mechanical Splice Connector 2/3mm:
Insert the fiber into the cleaver and stop at the correct
cleaving distance of 10mm for SC & LC connectors (Figure
8). If stripped correctly the 2/3mm jacket should be flush at
fiber holder stop
(57 and 27mm marks)