Hazardous Location Fittings
GUA Conduit Outlet Boxes
Application
GUA boxes can be used for hazardous
Rigid Fittings
®
Conduit & Fittings — T&B
location conduit runs for the following:
• Allows for mounting of fixture outlets
(when used with appropriate covers)
• Provides easy access to wiring
• Provides junction in conduit
for wire pulling and splices
• Changes direction in rigid
conduit systems
• Attaches two or more pieces
of conduit in long runs
• Guards against damage to wires
in rigid conduit
Features
• All hubs have a minimum of five
full threads and integral bushing
• All boxes are furnished with
internal grounding screw
• Cover supplied with O-ring gasket
GUA
GUAB
C B
A
B
C
GUA
CAT. NO.
HUB
SIZE
GUA14-TB
GUA16-TB
GUA24-TB
GUA26-TB
GUA36-TB 1" 2.31 3.50 .88 .935 1.035 16.2
GUA47-TB 1
GUA59-TB 1
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 1.81 2.50 .88 .570 .610 5.5
1
⁄2" 2.00 3.50 .88 .570 .610 13.5
3
⁄4" 2.00 2.50 .88 .755 .810 5.3
3
⁄4" 2.00 3.50 .88 .755 .810 13.3
1
⁄4" 2.69 4.38 1.00 1.260 1.360 29
1
⁄2" 3.81 5.75 1.06 1.470 1.590 70
GUAB
CAT. NO.
HUB
SIZE
GUAB14-TB1⁄2" 2.25 2.50 .88 .570 .610 6.9
GUAB16-TB
GUAB24-TB
GUAB26-TB
GUAB36-TB 1" 2.31 3.50 1.00 .935 1.035 15.4
GUAB47-TB 1
GUAB59-TB 1
GUAB69-TB 2" 4.06 5.75 1.06 1.880 2.047 80
GUAB79-TB 2
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 2.00 3.50 .88 .570 .610 13.5
3
⁄4" 2.50 2.50 .88 .755 .810 7.9
3
⁄4" 2.00 3.50 .88 .755 .810 13.5
1
⁄4" 2.69 4.38 1.00 1.260 1.360 27.5
1
⁄2" 3.81 5.75 1.06 1.470 1.590 73.6
1
⁄2" 4.06 5.75 1.13 2.320 2.380 98
A
CU. IN.
CAPACITYA B C MIN. MAX.
CU. IN.
CAPACITYA B C MIN. MAX.
Size Range
1
⁄2" NPT to 2" NPT
Access opening 2" to 5" diameter
Materials
Bodies .... Grade 60-45-10 Ductile Iron (Complies
Covers.................................. Die-cast aluminum
with ASTM standard A536)
Finish
Boxes .....Zinc-plated with aluminum acrylic paint
Covers....................................................Natural
Listings/Compliances
UL514A (wet locations when used
with gasketed covers)
UL886
CSA: C22.2 No. 30
CI. I, Div. 1 & 2, Groups C, D
CI. II, Div. 1, Groups E, F, G
CI. III, Div. 1 & 2
NEMA 3, 4, 7 CD, 9 EFG
Explosion-Proof
Dust-Ignition-Proof
Raintight
Wet Locations
GUAC
GUAD
GUAC
CAT. NO.
HUB
SIZE
GUAC14-TB1⁄2" 2.25 2.50 .88 .570 .610 6.8
GUAC16-TB
GUAC24-TB
GUAC26-TB
GUAC36-TB 1" 2.31 3.50 .88 .935 1.035 16.2
GUAC47-TB 1
GUAC49-TB 1
GUAC59-TB 11⁄2" 3.81 5.75 1.06 1.470 1.590 74
GUAC69-TB 2" 4.06 5.75 1.06 1.880 2.047 77.8
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 2.00 3.50 .88 .570 .610 13.1
3
⁄4" 2.00 2.50 .88 .755 .810 5.3
3
⁄4" 2.00 3.50 .88 .755 .810 13.3
1
⁄4" 2.69 4.38 1.00 1.260 1.360 29.3
1
⁄4" 3.81 5.75 1.00 1.260 1.360 73.6
CU. IN.
CAPACITYA B C MIN. MAX.
GUAD
CAT. NO.
GUAD14-TB1⁄2" 1.81 2.50 .88 .570 .610 5.6
GUAD16-TB
GUAD24-TB
GUAD26-TB
HUB
SIZE
1
3
3
GUAD36-TB 1" 2.31 3.50 .88 .935 1.035 16
GUAD49-TB 1
DIMENSIONS (IN.) THROAT DIA.
CU. IN.
CAPACITYA B C MIN. MAX.
⁄2" 2.00 3.50 .88 .570 .610 12.5
⁄4" 2.00 2.50 .88 .755 .810 5.2
⁄4" 2.00 3.50 .88 .755 .810 13.1
1
⁄4" 3.81 5.75 1.00 1.260 1.360 76
E-96
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
Hazardous Location Fittings
Conduit & Fittings — T&B
B
C
A
GUAL
GUAN GUAM GUAX
GUAL
CAT. NO.
HUB
SIZE
GUAL14-TB1⁄2" 2.25 2.50 .88 .570 .610 7.1
GUAL16-TB
GUAL24-TB
GUAL26-TB
GUAL36-TB 1" 2.31 3.50 .88 .935 1.035 16.2
GUAL47-TB 1
GUAL49-TB 1
GUAL59-TB 1
GUAL69-TB 2" 4.06 5.75 1.06 1.880 2.047 77.8
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 2.00 3.50 .88 .570 .610 13.4
3
⁄4" 2.00 2.50 .88 .755 .810 5.3
3
⁄4" 2.00 3.50 .88 .755 .810 13.3
1
⁄4" 2.69 4.38 1.00 1.260 1.360 30
1
⁄4" 3.81 5.75 1.00 1.260 1.360 74.5
1
⁄2" 3.81 5.75 1.06 1.470 1.590 74
CU. IN.
CAPACITYA B C MIN. MAX.
GUAM
CAT. NO.
HUB
SIZE
GUAM14-TB1⁄2" 1.81 2.50 .88 .570 .610 5.6
GUAM16-TB
GUAM24-TB
GUAM26-TB
GUAM36-TB 1" 2.31 3.50 .88 .935 1.035 14
GUAM47-TB 1
GUAM69-TB 2" 4.06 5.75 1.06 1.880 2.047 80
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 2.00 3.50 .88 .570 .610 12.5
3
⁄4" 2.00 2.50 .88 .755 .810 6.2
3
⁄4" 2.00 3.50 .88 .755 .810 12.5
1
⁄4" 2.69 4.38 1.00 1.260 1.360 29.2
CU. IN.
CAPACITYA B C MIN. MAX.
GUAN
CAT. NO.
HUB
SIZE
GUAN14-TB1⁄2" 2.13 2.50 .88 .570 .610 6.8
GUAN16-TB
GUAN24-TB
GUAN26-TB
GUAN36-TB 1" 2.31 3.50 .88 .935 1.035 16.9
GUAN47-TB 1
GUAN59-TB 1
GUAN69-TB 2" 4.06 5.75 1.06 1.880 2.047 84
DIMENSIONS (IN.) THROAT DIA.
1
⁄2" 2.00 3.50 .88 .570 .610 13.5
3
⁄4" 2.31 2.50 .88 .755 .810 7.7
3
⁄4" 2.00 3.50 .88 .755 .810 14
1
⁄4" 2.69 4.38 1.00 1.260 1.360 31.5
1
⁄2" 4.06 5.75 1.06 1.470 1.590 84
CU. IN.
CAPACITYA B C MIN. MAX.
GUAT
GUAW
C
GUAT
CAT. NO.
HUB
SIZE
GUAT14-TB1⁄2" 2.25 2.50 .88 .570 .610 7
GUAT16-TB
GUAT24-TB
GUAT26-TB
1
3
3
GUAT36-TB 1" 2.31 3.50 1.00 .935 1.035 15.9
GUAT37-TB 1" 2.31 3.50 .88 .935 1.035 23.3
GUAT47-TB 1
GUAT49-TB 1
GUAT59-TB 1
GUAT69-TB 2" 4.06 5.75 1.06 1.880 2.047 77.8
GUAT79-TB 2
DIMENSIONS (IN.) THROAT DIA.
⁄2" 2.00 3.50 .88 .570 .610 13.5
⁄4" 2.00 2.50 .88 .755 .810 5.3
⁄4" 2.00 3.50 .88 .755 .810 13.3
1
⁄4" 2.69 4.38 1.00 1.260 1.360 29.3
1
⁄4" 3.81 5.75 1.00 1.260 1.360 77.2
1
⁄2" 3.81 5.75 1.06 1.470 1.590 77.7
1
⁄2" 4.06 5.75 1.06 2.320 2.380 95
GUAW
CAT. NO.
HUB
SIZE
GUAW14-TB1⁄2" 1.81 2.50 .88 .570 .610 5.2
GUAW16-TB
GUAW24-TB
GUAW26-TB
1
3
3
DIMENSIONS (IN.) THROAT DIA.
⁄2" 2.00 3.50 .88 .570 .610 13
⁄4" 2.00 2.50 .88 .755 .810 6.5
⁄4" 2.00 3.50 .88 .755 .810 13
GUAX
CAT. NO.
HUB
SIZE
GUAX14-TB1⁄2" 1.81 2.50 .88 .570 .610 5.2
GUAX16-TB
GUAX24-TB
GUAX26-TB
1
3
3
GUAX36-TB 1" 2.31 3.50 1.00 .935 1.035 16
GUAX37-TB 1" 2.31 3.50 .88 .935 1.035 23.3
GUAX47-TB 1
GUAX49-TB 1
GUAX59-TB 1
GUAX69-TB 2" 4.06 5.75 1.06 1.880 2.047 77.8
DIMENSIONS (IN.) THROAT DIA.
⁄2" 2.00 3.50 .88 .570 .610 13.5
⁄4" 2.00 2.50 .88 .755 .810 5.3
⁄4" 2.00 3.50 .88 .755 .810 13.3
1
⁄4" 2.69 4.38 1.00 1.260 1.360 30
1
⁄4" 3.81 5.75 1.00 1.260 1.360 72
1
⁄2" 3.81 5.75 1.06 1.470 1.590 71
B
A
CU. IN.
CAPACITYA B C MIN. MAX.
CU. IN.
CAPACITYA B C MIN. MAX.
CU. IN.
CAPACITYA B C MIN. MAX.
®
Rigid Fittings
www.tnb.com
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
E-97