OBlue SUPER CLEAN AC-90573A Owner's Manual

OWNER’S MANUAL
SUPER CLEAN
®
FILTER - PUMP
AC-90573A
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING FILTER PUMP.
For enquiries and FAQs, please visit: www.oriental-sunbeach.com
Xian,Shanghai,China
Tel: 0086-21-57402084 Fax: 0086-21-57401306
1
You can help protect the environment! Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal center. Take out the batteries before scrapping the product.
A. Safety Instructions
When you want to install and use this filter pump, please
follow the following precautions:
1) WARNING ! Before starting, check all pipes and acces­sories for correct installation and reliable connection.
2) WARNING ! Do not bury the electric cords. Place the cords where lawn mowers, hedge trimmers and other equipment will not damage them.
3) WARNING ! Prevent children from using this filter pump without an adult's supervision.
4) WARNING ! To avoid the risk of electric shock, always be aware of damaged cords and have it repaired by a qualified electrician.
5) WARNING ! Do not use this filter pump when pool is empty. This pump is designed only for dismountable stor­able pools above the ground, not for permanently installed pools. Improper use may lead to overheating and will burn out the motor and damage it.
6) WARNING ! The power cord of this pump cannot be replaced. If the cord is damaged and cannot be repaired, the pump should be disposed of.
7) WARNING ! To avoid the risk of electric shock, connect the filter pump only to a receptacle protected by a ground­fault circuit interrupter (GFCI). Contact a qualified elec­trician if you cannot verify that the receptacle is GFCI protected. Use a qualified electrician to install the GFCI. Do not use a leakage protection receptacle.
8) WARNING! The filter pump must not be used when people are in the water
9) WARNING! The pump must be supplied through a re­sidual current device (RCD) having a rated residual op­erating current not exceeding 30mA
10)WARNING! The maximum total head in 2 meters
B. Installation Instructions
Please refer to the diagram 3-1 in page 3.
1) Before starting to install filter pump, be sure to assemble the pool frame first according to the pool's installation instructions step by step and fill it to the required water level.
2) Remove the filter pump and accessories from the packag­ing.
3) Put the filter pump at a proper position. Ensure that the filter pump is stable during its use and the highest point of the upper cover of filter pump shall be at least 150mm below the pool surface. (Note: there are four mounting holes in the pump base. If filter pump needs to be mounted on a stationary plane, you can fasten the pump with screws.)
4) Take two hoses and hose bundles to connect them to the inlet and outlet of filter pump.
5) Turn the air release valve on filter cover to "CLOSE" po­sition and then place the other end of the hose connect­ing the outlet (grey) of filter pump into the pool.
6) Connect the other end of the hose connecting the inlet (white) of filter pump and the hose bundle to the lower hose joint of the pool (but hose bundle cannot be tight-
ened). Then, open the water plug of lower hose joint, insert filter screen and finally tighten the hose bundle.
7) Take the other end of the hose connecting the outlet (grey) of filter pump out of the pool and connect it and the hose bundle to the upper hose joint of the pool (but hose bundle cannot be tightened). Then, open the water plug of up­per hose joint, insert filter screen and finally tighten the hose bundle.
C. Operation
1) Make sure that the pool is already filled with water and the filter pump is placed at a suitable position.
2) Turn the Air Release Valve 1 to "OPEN" position.
3) Turn the Air Release Valve to "CLOSE" position when water starts to flow from the drain port of air release valve (please refer to the diagram 3-2 in Page 3).
4) Connect the power cord to the electric outlet to operate the pump.
5) After water filtering, unplug the filter pump from the elec­tric outlet. Then, the filter pump stops working.
Precautions:
1) Empty the air in the pump with the air release valve be­fore turning on the pump.
2) Do not use the pump more than 48 hours continuously and ensure that the motor is fully cooled before next use.
3) Do not use the pump without water.
4) Please clean or change dirty filter cartridge timely, or it will affect the water pumping, which may cause the mo­tor to overheat, become noisy or even be damaged.
5) Please clean the filter cartridge after 84 hours continuous use. If the filter pump has decreasing flow and increas­ing noise after several times of cleaning, then it must be replaced by a new cartridge.
D. Maintenance and Replacement
Please refer to the diagrams 3-1 and 3-2 in page 3.
1) Make sure that the power cord of filter pump is discon­nected from the electric outlet.
2) Loosen the two hose bundles connected to the pool wall with screwdriver, take out two filter screens and plug the water plugs on two joints.
3) Turn the Cover 2 on the filter anticlockwise and remove Upper Cover Group (including Air Release Valve 1 and Upper Cover 2), O-ring 3 and Filter Cartridge 4in turn.
4) Check the filter cartridge body of the Filter Housing 7 for dirt or sediment. If any, flush it.
5) Mount the new or cleaned filter cartridge into the Filter Housing 7.
6) Mount O-ring 3 and Upper Cover Group onto the filter pump in turn.
7) Turn the Cover 3 in a clockwise direction and ensure that, after tightening, the filter pump does not leak during nor­mal work.
8) Turn the Air Release Valve 1 to "CLOSE" position.
9) Pull out the water plugs of the two hose joints on the pool wall, insert the filter screens and finally tighten the two hose bundles with screwdriver.
2
3-1
3-2
(Illustration Not to Scale)
3
WARRANTY
This limited warranty applies to the ORPC Super Clean® only. This warranty is in effect for one year after purchase. The foregoing warranties relate to the original consumer purchaser only.
ORPC shall have the option to repair or replace the defective product, as its sole discretion. Purchasers must pay all labor and shipping charges necessary to replace the product covered by this warranty.
This warranty shall not apply to any product that has been subject to negligence, misapplication, improper installation or maintenance, or other circumstances that are not in ORPC’s direct control.
The provisions of this warranty is also not covered swimming pool, the costs of the loss of pool water, chemicals or water damage. Injury or damage to any property or person is also not covered by this warranty.
ORPC is to be contacted at the address below, so that a return authorization (RA) number should be obtained before return
item. In order to return an item to us, the item must contain all parts, invalid documents, manuals, RA number, and be packed properly in its original box. The item must be received by us clean & in good working order.
4
Head Office & Factory: No.1699 Da Ye Road,Wuqiao,Feng Xian,Shanghai,China
Tel: 0086-21-57402084 Fax: 0086-21-57401306
MODE D'EMPLOI
POMPE A FILTRER SUPER PROPRE
®
AC-90573A
ATTENTION: IL FAUT LIRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS AVANT
D'INSTALLER LA POMPE A FILTRER.
POUR plus de renseignments, veuillez visiter: www.oriental-sunbeach.com
Siège & Usine: No.1699 Da Ye Road , Wu qiao, Feng Xian, Shanghai, China
Tel: 0086-21-57402084 Fax: 0086-21-57401306
5
Vous pouvez aider à protéger l’environnement ! N’oubliez pas de respecter les règlements locaux : apportez les appareils électriques ne fonctionnant plus au service local de retraitement des déchets.
Retirez les piles avant de mettre l’appareil au rebut.