Oblica PaxFocus Installation And User Manual

PAXFOCUS
INSTALLATION AND USER MANUAL
1. TECHNICAL DATA 2
2. PRE-INSTALLATION 3
3. INSTALLATION 5
4. OPERATION 13
5. TESTING 14
Keep for future use
OBLICA
200 Argyle St
Fitzroy VIC 3065
1. TECHNICAL DATA
WEIGHT AND DIMENSIONS:
Firebox diameter W950mm x D650mm Firebox weight 66Kg Flue diameter 219mm Flue weight 16Kg/meter External flue kit Triple skin 200/250/300mm
DETERMINED UNDER TEST CONDITIONS:
Nominal thermal output 5kW Efficiency 46,1%
PAXFOCUS ATTACHED TO NON COMBUSTABLE WALL
ø219 mm
360 mm
FLUE
FIREBOX
ø950 mm
OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL
PAGE 2
2. PRE-INSTALLATION
Congratulations on your purchase of the PaxFocus. This appliance should be installed and checked by a qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns please contact Oblica on 03 9416 0400.
The installation process is outlined below: – Determine position of firebox and flue carefully observing the clearances described within this section – Install the suspension bracket – Install the external flue – Install the internal flue and engage the firebox – Ensure the floor has adequate protection
CAUTION:
Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance.
WARNING:
• The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the relevant building code or codes.
• Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS/NZS 4013.
• Once the flue has been installed and approved by a professional installer, the flue must not be modified in any way.
OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL
PAGE 3
700 350
Combustible Wall
Non Combustible
350
Glass
2. PRE-INSTALLATION (CONTINUED)
29 07 1313
07
RRF - 1625
MINIMUM CLEARANCE – INTERNAL
2.1 Clearance from non-combustible surfaces (eg masonry)
There is no minimum clearance required from fully non-combustible surfaces.
Non Combustible – Masonry Wall
2.2 Clearance from glass
350mm minimum clearance is required from normal non-combustible glass.
150mm minimum clearance is required from toughened glass.
2.3 Clearance from combustible surfaces (eg timber joist & plasterboard)
700mm minimum clearance is required on the sides.
Non Combustible – Masonry Wall
Combustible Wall
700
Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Building Code.
For information on heat shielding please contact our
Non Combustible
350
IMPORTANT:
Frames must also be considered. Timber window frames must be treated as combustible surfaces (see 2.3). Aluminium frames can be treated as non-combustible surfaces (see 2.2).
office on 03 9416 0400 or email info@oblica.com.au.
Glass
700
Ventilation Grill
150
≥1350
OBLICA | PAXFOCUS INSTALLATION AND USER MANUAL
PAGE 4