Assembly Components:
- Door Assembly – 1 each
- #8 – 32 screws – 4 each
- #8 – 32 he
If any of these items are missing, contact your Oberon representative.
Tools required: Screwdriver & Wrench Set
Find a flat work surface to assemble the mounting plate, access point, and door.
NOTE: If using Cisco 1040, 1140,
1260, 3500 series access point use
Cisco AIR-AP-BRACKET-2. If using
Cisco 3600 series use Cisco AIR-APBRACKET-1.
Step 1 – Install the mounting plate onto
the mounting bracket using the (4) # 832 screws. The triangle cutouts of the
mounting plate should face toward the
cutout on the bracket. Slide the access
point onto the mounting plate using the
feet to lock it in place (Figure 1).
x nuts – 4 each
Installation Instructions
Model Number 38-52-CCOAP
Figure 3
Final Assembly
Step 3 – Re
and replace it with the new door assembly. To remove the
old door, open the enclosure and remove the three (3) hex
nuts holding the door in place (Figure 3).
NOTE: If required, remove lock from old door and
replace on new door.
move the current door (if not previously done)
Figure 1
Step 2 – The door assembly is completed by attaching
the previously assembled mounting plate/access point
assembly to the enclosure door by securing it in place
with four (4) #8-32 hex nuts. Place the slotted holes in
the mounting plate/access point assembly over the
studs located on the bottom side of the door (NOTE:
the mounting plate can only be attached to the door in
one direction. If the slotted holes don’t match up with
the studs in the door, rotate the mounting plate 180°).
Once the mounting plate is positioned, secure it in
place by installing four (4) #8-32 hex nuts (Figure 2).
Figure 2
Page 2
(877) 867-2312 www.oberonwireless.com
Rev. 7/25/11 Oberon, Inc. 1315 South Allen Street State College, PA 16801 Copyright 2011
Step 4 – Install the door assembly by placing the three
(3) mounting holes in the door over the studs on the
hinge and then replace the nuts (Figure 4).
Page 3
Figure 4
MODEL 38-52-CCOAP
Installation Instructions
**** WARNING ****
Please thoroughly read the product warning below
before installation to provide for a safe work
environment.
1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical
Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or
other means must be used for the installation of this product in the ceiling. Acoustical, suspended, false, drop and
concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with
independent support wires, wire rope, threaded rod, or other secure support means of adequate gauge and fire
resistance.
2. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door
from accidentally swinging open.
3. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.
4. This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not
exceed this temperature, depending on power dissipation within enclosure.
5. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be
maintained for the safe operation of the equipment.
6. This product is intended to be installed by trained personnel.
7. Only Listed ITE shall be installed within the enclosure.
8. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or
replacement.
9. Maximum weight to be installed in the unit is 25 lbs.
10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that
complies with UL 2043 or UL 1479.
11. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.
12. If AC power is used inside the enclosure, connect the ground wire to the green ground screw located near the
knockout in the backbox.