OBERON 1044-CCOAP3800-B Installation Instructions Manual

Installation Instructions
Model Number 1044-CCOAP3800-B
(877) 867-2312 www.oberonwireless.com
Rev. 08/30/17 Oberon, Inc. ••• 1315 South Allen Street •••• State College, PA 16801 Copyright 2017
- Suspended Ceiling Kit Model 1044-CCOAP asse mbly – 1 each
- Trim with Mounting Bracket – 1 each
- #8-32 x 1/4" Screw – 4 each
- #8-32 x 1/4" M/F Standoff – 4 each
- 1/4" - 20 Wing Nuts – 2 each
- Firestop Grommet – 1 each
- 1" Conduit Connector – 1 each
- Hanger wire – 4 each
If any of these items are missing, contact your Oberon representative.
Find a flat work surface to assemble the ceiling kit, access point and antenna(s) prior to mounting in ceiling.
Step 1 –
Remove any knockouts from the back box needed for cable egress. Fasten the conduit connector to the back box through the now open knockout (Figure 1).
Step 2 – Remove the ceiling tile and cut an 11" x 9" opening. Be sure to center the opening along the centerlines of the tile. (Figure
2).
Page 2
Step 3 – Place the t ile back in the ceiling with the back box and tile bridge over top. Attach the hanger wires to the f our tabs located on the corners of the back box and then to a permanent structure within the ceiling. Slide the cables through the conduit connector and sna p the Firestop Grommet over the cables (F igure 3). Make sure there is enough slack in the cabling to attach to the access point.
NOTE: A surface mount box (or biscuit jack) and equipment cord can be conveniently mounted inside the Model 1044. (Non-plenum rated cables can be used inside a plenum rated enclosure). Use an adhesive backed surface mount box. Consider bend radius of horizontal cable and equipment cord when attaching the surface m ount box.
Step 4 – To attach the access point to the trim, first remove the two hex nuts that hold the aluminum mounting plate to the painted trim piece. Next attach the Cisco AIR-­_BRACKET-2 to the mounting plate using the four (4) screws provided. The Cisco mounting bracket should be aligned so t hat the Et hernet jacks of the access point will face toward the cut out area of Oberon mounting plate (Figure 4).
Step 5 - Af ter the Cisco mounting bracket has been installed on the Oberon mounting plate, attach the Cisco 3800 to the Cisco AIR-BRACKET-2. To finish the trim assembly, re­attach the painted trim using the nuts removed in St ep 4.
Page 3
Figure 1 - Conduit Connector Installation.
Figure 2 - Ceiling Tile Cutout.
Figure 4 - AP and Trim Installation.
Figure 3 - Firestop Grommet Installation
Step 6 - Insert trim assembly through the cutout hole in the ceiling tile so that the threaded studs go through the outer holes in the tile bridge. Use the supplied wing nuts to tighten the trim us to the ceiling tile. The trim should be tightened so the it is snug against tile, however, do not over tighten as it may damage either the tile or trim
Note: Take proper safety precautions as many wall/ceiling areas may have electrical or plumbing located behind them.
Page 4
MODEL 1044-CCOAP3800-B
Installation Instructions
**** WARNING ****
Please thoroughly read the product warning below
before installation to provide for a safe work
environment.
1. The Cabinet System Communications are intended to be installed in accordance with the applicable requirements of the NFPA 70, “National Electrical Code” (NEC), and/or the applicable sections of ANSI C2, “National Electrical Safety Code” (NESC). The Authority Having Jurisdiction will be responsible over the final installation to determine if the final configuration meets the necessary criteria for the installation and use.
2. The Cabinet System Communication is configured in the field by qualified service personnel.
3. Ambient Temperature - A manufacturer's maximum specified operating ambient of 55°C; so that the installer is able to determine acceptability of use of Accessories and components in the operating state.
4. A readily accessible disconnect device shall be incorporated in the building installation wiring.
5. The instructions may include the product Load Ratings or those ratings shall be placed on the product. Maximum weight to be installed in the unit is 25 lbs.
6. Only Listed ITE products shall be installed within the enclosure.
7. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or replacement.
8. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non­metal material that complies with UL 2043 or UL 1479.
9. All unused mounting holes should be sealed with tape or other material that complies with UL
1479.
10. AC power is NOT to be used inside the enclosure.