6 DFU SURE-VENT®
AIR ADMITTANCE VALVE WITH
TUBULAR ADAPTER
TECHNICAL SPECIFICATION: The purpose of an Air Admittance Valve is to provide a method of allowing air to enter the
plumbing drainage system without the use of a vent extended to open air and to prevent sewer gases from escaping into a building. An Air Admittance Valve is a one way valve designed to allow air to enter the plumbing drainage system when negative pressures develop in the piping system. The device shall close by gravity and seal the vent terminal at zero differential pressure (no flow conditions) and under positive internal pressures.
Materials and Dimensions
Valve – PVC with 1-½” NPT Threads
Tension Membrane – Neoprene
Adapter – 1-½” Polypropylene
Features
Rated 6 DFU’s for venting DWV 2” and smaller
Sweet Spot™ technology opens at -0.01 psi and
seals at 0 psi and above
Screening on air inlets to guard the seal
Protective rubber sleeve provides grip for
installation and keeps valve free from debris
100% functionally tested at ¼” H
ensuring trouble free performance
Limited Lifetime Warranty
Listings
ASSE 1050 & 1051
ICC ESR-1664
NSF Standard 14
IAPMO – Classified Mark
ASTM F-409
Code Approvals
International Plumbing Code (IPC) 2003
International Residential Code (IRC) 2003
O and 30” H2O
2
Installation: Read installation instructions prior to use of this product. Always consult local plumbing codes prior to installing an AAV. Individual, branch and circuit vents are permitted to terminate with a
connection to a Sure-Vent® AAV. The Sure-Vent® AAV will only vent fixtures that are on the same floor and
connect to a horizontal branch drain. The horizontal branch drain shall connect to the drainage stack a maximum of four branch intervals from the top of the
stack. The Sure-Vent® AAV should be located within the maximum developed length permitted for the vent. The Sure-Vent® AAV must be located a minimum of 4 inches above the horizontal branch drain and 6 inches
above any insulation material and within 15 degrees of vertical. Every structure in which plumbing is installed shall have at least one primary stack vent. The stack vent should run as directly as possible from the building drain through to the open air.
Remove protective orange rubber sleeve after installation.
Sure-Vent® AAV are intended for installation in the confines of a structure, cannot be exposed to outside elements and are intended for use between -40° F and
150° F. AAVs must be accessible for inspection and service.
39225 6 DFU AAV with 1-½” white tubular adapter 6 3 lbs. 39226 6 DFU AAV with 1-½” black tubular adapter 6 3 lbs. 39239 6 DFU AAV Installation Pack with white tubular adapter 6 3 lbs. 39245 6 DFU AAV with 1.5” Tubular Trap & Tee 20 15 lbs.