No New Roof Penetrations!
SURE-VENT® AIR ADMITTANCE VALVES
TECHNICAL SPECIFICATIONS
Plumbing Drain, Waste and Vent systems, known as DWV, consist of the DRAIN pipes that provide
a network for the removal of WASTE and the VENT pipes that prevent traps from siphoning and
maintain an equalized pressure. The DWV system uses gravity and air displacement throughout
the piping network to function and breathe. In a simplified example, water in an inverted bottle
without an air hole will glug and gasp when emptied. Adding an opening to the bottom of the
bottle will turn the process into an efficient, steady flow because the bottle “breathes.”
Engineering Specification:
The purpose of an air admittance valve is to provide a method of allowing air to enter the plumbing system without
the use of a vent extended to open air and to prevent sewer gases from escaping inside a building.
FEATURES
- Four vents rated at 6, 20, 160 and 500 DFUs for optimized installations
- Sweet SpotTM technology opens at -0.01 psi (-0.25” H2O) and seals at
0 psi and above
- Screening on air inlets to guard the seal
- Protective rubber sleeve provides grip for installation and keeps valve
free from debris
- 100% functionally tested at 0.25" water and 30" water ensuring
trouble-free performance
- Limited Lifetime Warranty
LISTINGS
- ASSE 1050 & 1051 (Rev. 2002)
- NES NER-670
- NSF Standard 14
- IAPMO – Classified Mark
- ASTM D2661/D2665/F409
CODE APPROVALS
- International Plumbing Code (IPC) 2003
- International Residential Code (IRC) 2003
- Uniform Plumbing Code (UPC) 2003 – Section 301.2
INSTALLATION
Read installation instructions prior to use of this product. Always consult
local plumbing codes prior to installing an AAV. Individual, branch and circuit
vents are permitted to terminate with a connection to a Sure-Vent
Sure-Vent® AAV will only vent fixtures that are on the same floor level and
connect to a horizontal branch drain. The horizontal branch drain shall
connect to the drainage stack a maximum of four branch intervals from the
top of the stack. The Sure-Vent
developed length permitted for the vent. The Sure-Vent® AAV must be
located a minimum of 4 inches above the horizontal branch drain and 6
inches above any insulation material and within 15 degrees of vertical. Every
structure in which plumbing is installed shall have at least one primary stack
vent. The stack vent should run as directly as possible from the building
drain through to the open air.
Use approved pipe joint compound on the threads of the valve and remove
protective orange rubber sleeve after installation.
®
Sure-Vent
cannot be exposed to outside elements and are intended for use between
-40°F and 150°F. AAVs must be accessible for inspection and service.
AAVs are intended for installation in the confines of a structure,
®
AAV should be located within the maximum
®
AAV. The
AIR
ADMITTANCE
VALVES
Traditional
Vented
House
EVERY DRAIN NEEDS A TRAP.
EVERY TRAP NEEDS A VENT.
To prevent sewer gases from being released into the
structure, plumbing code requires a trap to be installed at
every fixture. A trap is a U-shaped bend of pipe filled with
water that acts as a barrier between the structure and the
sewer system. Trap seals can only be compromised under
two conditions — high sewer pressures and water siphons,
in both cases vents prevent this from happening.
Under high sewer pressures without a vent, trap seals will
allow sewer gases to escape and enter the structure. This
happens when the sewer pressure is greater than the
pressure from the column of water in the trap. A vent will
keep the sewer and atmospheric pressures equalized to
maintain the trap seal.
Water moving through pipes can create a negative pressure
or a siphon. The siphon will pull the water from a trap,
leaving a clear path for sewer gases to enter the structure.
A vent will prohibit siphoning, maintaining the trap seal.
AAV
Vented
House
WHY USE A SURE-VENT®
AIR ADMITTANCE VALVE?
Air Admittance Valves (AAVs) open and close in conjunction
with normal DWV system operation, effectively eliminating
the need for secondary vent pipes. An AAV provides an
alternative to secondary venting when utilized within the
scope of model plumbing codes, referenced standards and
Oatey installation instructions.
AAVs provide the ideal venting solution for island sinks,
remote bathroom groups and remodeling jobs by eliminating
the need to tie into a stack vent.
AAVs are often more economical than running vent pipe in
new construction because they reduce the added need for
supplies and labor.
The Oatey Sure-Vent® offers UNMATCHED PERFORMANCE by
opening and closing under the smallest pressures, multiple
sizes for OPTIMIZED DFUs and SUPERIOR SEALING
technology, providing a lifetime of reliability.
©2012 Oatey SCS. All Rights Reserved.
This information is based on data believed to be reliable but Oatey makes no warranties, express or implied,
as to its accuracy and assumes no liability arising out of its use. The data listed falls within the normal range
of product properties but should not be used to establish specication limits or used alone as the basis of
design. Oatey’s liability to purchasers is expressly limited to the terms and conditions of sale.
Oatey is a trademark of Oatey Co. All other trademarks can be found on www.oatey.com.
DISTRIBUTED BY:
216. 267.710 0 / 800.321.9 53 2
www.oateyscs.com
U.S. Patent 6,415,816
and others pending
For Island Sinks & Bathrooms
Allows Air into the Plumbing System - Contains
Foul Odors
4700 W. 160th St. | Cleveland, OH 44135 | 800.321.9532 | Fax: 800.321.9535 | www.oatey.com
AAVtrifold_LCS420C_101812.indd 1 10/18/12 9:45 AM
LCS 420 C 10/12
Which DFU Is Right for You?
Unmatched Performance AAVs and Accessories
Make the right choice
Sensitivity to pressure changes, combined with its ability
to consistently open and close, is what distinguishes the
Oatey® Sure-Vent® AAV from all others. Superior engineering
along with stringent quality standards ensure a lifetime of
unmatched performance.
Available in 6, 20, 160, and 500 DFU. An air admittance
valve’s ability to breathe is measured in Drainage Fixture
Units or DFUs. The higher the DFU rating on the valve, the
greater amount of air that can enter the DWV system. DFU
loads are assigned to plumbing fixtures dependent on the
volume rate of discharge, the duration of operation and
the time between operations. Common fixture load ratings
are shown in the table.
To ensure proper breathing capability, determine all
fixtures to be vented and calculate the total
DFU load,
then select the appropriate Sure-Vent® for the application.
Each Oatey Sure-Vent® cap indicates its maximum DFU
rating — 6, 20, 160 and 500 DFUs.
Example: In a house with a laundry room and bathroom sharing a common wall, the DFU load
would total nine. Five for the bathroom, three for the washing machine and one for the laundry
tub. The 20 DFU Sure-Vent® is the right AAV for the job.
It is acceptable to oversize a Sure-Vent®; however, an undersized Sure-Vent® will not allow the
plumbing system to breathe properly.
FIXTURE
APPLICATIONS
LOAD
Traditional Public Bathroom Group
(Toilet (1.6 gpf), bathtub w/ shower,
and sink)
Traditional Private Bathroom Group
(Toilet (1.6 gpf), bathtub w/ shower,
and sink)
Public Toilet (1.6 gpf) 4
Private Toilet (1.6 gpf) 3
Washing Machine 3
Bathtub w/ Shower 2
Sink & Disposal 2
Dishwasher 2
Shower Stall (5.7 gpm or less) 2
Sink 2
Drinking Fountain 0.5
2012 International Plumbing Code Section 709 Fixture Units
Sure-Vent® Wall Boxes
DFU
6
5
Sensitivity to pressure changes, combined with its ability to consistently open and close, distinguishes the Oatey
®
Sure-Vent
AAV from all others. Superior engineering along with stringent quality standards ensure a lifetime of
unmatched performance.
ZERO PRESSURE
At zero pressure the Sure-Vent® AAV is
sealed, ready to react to pressure
changes. The Sure-Vent® AAV will not
allow sewer gas to enter the structure.
NEGATIVE PRESSURE
A pressure change of -0.01 psi (-0.25”
H2O) will cause the Sure-Vent® AAV to
open. When open, air will flow from the
room, through the protective screening,
past the seal and into the DWV system
as the arrows indicate. When pressure
is equalized, the Sure-Vent
®
AAV returns
POSITIVE PRESSURE
The Sure-Vent® AAV seals at 0 psi and
above indefinitely. The figure shows the
Sure-Vent® AAV in a sealed position
blocking sewer gasses. When pressure
subsides, the Sure-Vent
the zero pressure position.
®
AAV returns to
to the zero pressure position.
Superior Sealing
The Oatey Sure-Vent® utilizes the most advanced sealing technology available. The patented tension
membrane design results in superior sealing, guaranteed.
Sealed
Position
Slide
Open
Position
Pressure
Position
Oatey offers a wide range of Air Admittance Valves and accessories to enable installation in virtually
any application. Included are new polystyrene wall boxes, which are a convenient, easy to use solution
for recessed installations. Available with PVC or ABS adapters.
PRODUCT DESCRIPTION PACK
39228 6 DFU AAV with 1½" PVC Schedule 40 adapter 6
39229 6 DFU AAV with 1½" ABS Schedule 40 adapter 6
39005 6 DFU AAV with 1½" PVC Schedule 40 adapter 50
39227 6 DFU AAV with 1½" ABS Schedule 40 adapter 50
39225 6 DFU AAV with 1½" white tubular adapter 6
39226 6 DFU AAV with 1½" black tubular adapter 6
39016 20 DFU AAV with 1½" x 2" PVC Schedule 40 adapter 6
39018 20 DFU AAV with 1½" x 2" ABS Schedule 40 adapter 6
39017 20 DFU AAV with 1½" x 2" PVC Schedule 40 adapter 50
39019 20 DFU AAV with 1½" x 2" ABS Schedule 40 adapter 50
39220 160 DFU AAV with 2" x 3" PVC Schedule 40 adapter 6
39221 160 DFU AAV with 2" x 3" ABS Schedule 40 adapter 6
39223 500 DFU AAV with 3" x 4" PVC Schedule 40 adapter 6
39224 500 DFU AAV with 3" x 4" ABS Schedule 40 adapter 6
®
39260 Sure-Vent
39261 Sure-Vent
39262 Sure-Vent
39263 Sure-Vent
39010 Sure-Vent Wall Box with Metal Grille Faceplate 12
39011 Metal Grille Faceplate for Wall Box 10
34247 Louvered Design Access Panel 12
Wall Box 6
®
Wall Box Louvered Faceplate 6
®
Box Kit with PVC Adapter and 20 DFU AAV 6
®
Box Kit with ABS Adapter and 20 DFU AAV 6
Whether you want traditional metal wall boxes or newer boxes made from polystyrene, Oatey has
the box you need for your application.
Tension
Membrane
METAL WALL BOXES
• Allows access to Sure-Vent air
admittance valve.
• Fits Oatey Sure-Vents – 6, 20, 160 DFU
(Sold Separately.)
POLYSTYRENE WALL BOXES
• New, smaller size: 4½" x 5¾".
• High-impact polystyrene construction.
• Accommodates 6 or 20 DFU AAVs with
1½" or 2" adapters.
• UPC listed.
SWEET SPOTTM
Securing only the perimeter of the gasket
to the slide creates a soft centered
tension membrane resulting in a Sweet
TM
. The flexible portion of the gasket
Spot
is utilized to produce a reliable debris
OPENING
Sure-Vent® is the only AAV that opens
at low pressures and seals tightly.
The large area of the Sweet SpotTM
seal allows the Sure-Vent
at extremely low pressures.
®
to open
45-DEGREE EDGE
Designed with a 45° edge, the sealing
surface of the Sure-Vent® AAV prevents
particulate build-up. The self-wiping
feature keeps the sealing surface clean.
tolerant Sweet SpotTM seal.
AAVtrifold_LCS420C_101812.indd 2 10/18/12 9:45 AM
Reliable seal
guaranteed.
(U.S. Patent 6,415,816 & others pending)
U.S. Patent 6,415,816 & others pending