Section 1: Getting Started
1. INSPECTION
Inspect the cartons and various components for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.
2. INSTALLATION, PLUMBING & ELECTRICAL CONNECTIONS
a) Note: The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI. CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well. State and local plumbing codes may prohibit the use of saddle tapping valves for water line connection in some applications. All connections must conform to applicable plumbing codes.
3. OVERLOAD PROTECTION (systems with chiller) The compressor motor is equipped with an automatic reset protector which will disconnect the motor from the line in case of overload.
4. LUBRICATION (systems with chiller) This unit is equipped with a hermetically sealed compressor. No additional lubrication is required. The fan motor installed on this unit seldom needs oiling. If required, a few drops of SAE 10 oil should be used.
5. TO DISCONTINUE USE OF SYSTEMS WITH CHILLER
Drain cooler when removed from service: (1) Remove grille, (2) Close supply valve, (3) Provide container to catch water, and remove drain plug.
6. MAINTENANCE (systems with chiller) The only maintenance required is the removal of dirt and lint from the condenser. Inspection should be made at 3 month intervals. Remove the grille and clean the condenser with a vacuum attachment.
WARNING
The warranty and the Underwriters' Laboratory Listing for this machine are automatically voided if this machine is altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flooding and/or hazardous electrical shock or fire.
EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR AGREEMENT EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
2
Section 2: Rough In Drawing
OASIS Modular Hands-Free QUASAR VersaFiller (with or without VersaFilter II and
Remedi Filter)
Models MWEBQ, MW8EBQ, MW12EBQ, MWF2EBQ, MW8F2EBQ, MW12F2EBQ
3
Section 2: Rough In Drawing
OASIS Modular Hands-Free QUASAR VersaFiller (with or without VersaFilter II and
Remedi Filter)
Models M8EBQ, M12EBQ, M8F2EBQ, M12F2EBQ
4
Section 2: Rough In Drawing
OASIS Modular Hands-Free QUASAR VersaFiller (with or without VersaFilter II and
Remedi Filter )
Models MWSMEBQ, MWSM8EBQ, MWSM12EBQ, MWSMF2EBQ,
MWSM8F2EBQ, MWSM12F2EBQ
5
Section 3: Installation– Without Chiller
FASTENING POINTS ON FRAME (QTY. FOUR) 5/16” MOUNTING HOLES TOP AND BOTTOM REAR FLANGES.
2X4 JUNCTION BOX
OUT
*DRAIN ASSEMBLY
*SNAP BUSHINGS
DRAIN COMPONENTS NOT INCLUDED
*MOUNTING SCREWS (2 PROVIDED)
OPTIONAL VERSAFILTER II LOCATION IF NO CHILLER
IN
STEP 1- INSTALL FRAME ASSEMBLY
A) INSTALL FRAME ASSEMBLY PER ROUGH-IN DRAWING. NOTE, IF APPLICABLE, REFER TO
TRIM BEZEL INSTALLATION INSTRUCTIONS ON PAGE 8 BEFORE CONTINUING WITH STEP 2. NOTE THE FRONT FLANGE OF THE FRAME MUST BE FLUSH WITH THE FINISHED WALL
SURFACE UNLESS A TRIM BEZEL IS DESIRED. B) INSTALL DRAIN ASSEMBLY C) INSTALL SNAP BUSHINGS D) MOUNT OPTIONAL FILTERS. WALL OPENING DEPTH MUST BE AT LEAST 5” DEEP TO
ACCOMMODATE THE VERSAFILTER II. E) INSTALL PROVIDED STEM ELBOWS ON THE INLET AND OUTLET OF THE FILTERS.
OUT
OPTIONAL FILTER LOCATION IF NO CHILLER
IN
* PROVIDED WITH BOTTLE FILLER
66