![](/html/3a/3a91/3a91b2162b3fbbade82998223d46506212c9326fe3e00c83499fd8a1b40be52e/bg1.png)
FiltoMatic CWS 7000/14000 /25000
![](/html/3a/3a91/3a91b2162b3fbbade82998223d46506212c9326fe3e00c83499fd8a1b40be52e/bg7.png)
- GB -
- GB -
Foreword
Welcome to OASE Living Water. You made a good choice with the purchase of this productFiltoMatic
CWS .
Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself
with the unit. Ensure that all work on and with this unit is only carried out in accordance with these
instructions.
Adhere to the safety information for the correct and safe use of the unit.
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on
to a new owner.
Table of Contents
1 Scope of delivery.............................................................................................................................. 23
2 Overview .......................................................................................................................................... 23
3 Legal conditions ............................................................................................................................... 23
4 Safety information ............................................................................................................................ 24
5 Installation ........................................................................................................................................ 25
6 Installation ........................................................................................................................................ 26
7 Start-up............................................................................................................................................. 27
8 Operation.......................................................................................................................................... 28
9 Remedy of faults .............................................................................................................................. 31
10 Maintenance and cleaning ............................................................................................................... 32
11 Wear parts........................................................................................................................................ 36
12 Storage/Over-wintering .................................................................................................................... 36
13 Disposal............................................................................................................................................ 36
Technical data ........................................................................................................................................ 337
Symbols on the unit................................................................................................................................ 341
Spare parts ............................................................................................................................................. 342
3.1 Intended use ............................................................................................................................ 23
3.2 Extended guarantee conditions for the OASE ClearWaterSystem.......................................... 23
4.1 Hazards encountered by the combination of water and electricity .......................................... 24
4.2 Correct electrical installation .................................................................................................... 24
4.3 Safe operation.......................................................................................................................... 24
8.1 Controller overview .................................................................................................................. 28
8.2 Setting the dirty water pump ....................................................................................................29
8.3 Setting the UVC clarifying unit .................................................................................................30
10.1 Cleaning foam filters ................................................................................................................ 32
10.2 Remove and separate the cleaning components from each other .......................................... 32
10.3 Cleaning the dirty water pump ................................................................................................. 33
10.4 Changing the UVC lamp in the UVC clarifying unit.................................................................. 33
10.5 Checking the cleaning rotor .....................................................................................................34
10.6 Changing the foam filters ......................................................................................................... 34
10.7 Thorough cleaning of the unit .................................................................................................. 35
22
![](/html/3a/3a91/3a91b2162b3fbbade82998223d46506212c9326fe3e00c83499fd8a1b40be52e/bg8.png)
1 Scope of delivery
► Open the lid (1) using the rotary handle (2) to remove the assembly components (Figure A).
Figure B Number Description
3 1 Container FiltoMatic CWS
4 1 Outlet DN70
5 1 Flat sealing DN70
6 1 Flat sealing 1 ½“
7 1 O ring DN40
8 1 Outlet sheath DN40
9 1 Inlet sheath 1 ½“
10 2 Union nut
11 1 Hose clip
1 Instructions for use
1 Fast assembly instruction manual
1 Guarantee brochure
1 Clear water guarantee card
1 Guarantee extension card 2+1
2 Overview
Figure C Designation For a description, please refer to Chapter …
3 Container Assembly, cleaning and maintenance
4 Outlet DN70 Installation
8 Dirty water outlet DN40 Installation
9 Inlet 1 ½“ Installation
12 Soiling indicator Maintenance and cleaning
13 Foam holder Maintenance and cleaning
14 Dirty water pump Maintenance and cleaning
15 Controller Operation
16 UVC clarifying unit Maintenance and cleaning
17 Stop valve for inlet Starting up, cleaning and maintenance
18 UVC lamp control window Maintenance and cleaning
19 Engagement hooks Maintenance and cleaning
20 Biokick CWS infill opening Start-up
- GB -
3 Legal conditions
3.1 Intended use
The FiltoMatic CWS is intended as a filter system for the mechanical and biological cleaning of garden
ponds having a water temperature of between +4 °C and +35 °C. The unit is exclusively suited for
private use and may only be employed for cleaning garden ponds with or without fish population.
3.2 Extended guarantee conditions for the OASE ClearWaterSystem
Guarantee claims can only be brought forward to us, OASE GmbH, Tecklenburger Straße 161 in
D-48477 Hörstel, by returning to us the unit or part of the unit subject to complaint, freight free, at your
own risk, accompanied by the original purchase receipt from the OASE specialist dealer, this guarantee
document and written information of the fault encountered. Should the dirty water pump, UVC clarifying
unit or controller be defective, only return the individual defective component (dirty water pump, UVC
clarifying unit, controller), not the complete unit.
23
![](/html/3a/3a91/3a91b2162b3fbbade82998223d46506212c9326fe3e00c83499fd8a1b40be52e/bg9.png)
- GB -
4 Safety information
Hazards to persons and assets may emanate from this unit if it is used in an improper manner or not in
accordance with its intended use, or if the safety instructions are ignored.
This unit can be used by children from the age of 8 and by persons with physical,
sensory or mental impairments or lack of experience and knowledge, as long as they
are supervised or instructed on how to use the unit safely and are able to understand
the potential hazards. Do not allow children to play with the unit. Do not allow children
to clean or maintain the unit without close supervision.
4.1 Hazards encountered by the combination of water and electricity
► The combination of water and electricity can lead to death or severe injury from electrocution, if the
unit is incorrectly connected or misused.
► Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
4.2 Correct electrical installation
► For your own safety, consult a qualified electrician when you have questions or encounter problems.
► Electrical installations at garden ponds must meet the international and national regulations valid for
installers. Especially adhere to DIN VDE 0100 and DIN VDE 0702.
► Compare the electrical data of the power supply with those indicated on the type plate on the UVC
clarifying unit.
► Only operate the FiltoMatic CWS when plugged into a correctly fitted socket.
► Please note that the power supply must be fused via a fault current protection system with a
maximum reference fault current of 30 mA.
► Install the FiltoMatic CWS such that any risk of injury to persons is excluded.
► Only use cables that are uncoiled.
► Extension cables must be approved for outdoor use and meet DIN VDE 0620 standards.
► Route the connection cable so that damage is excluded.
► Keep all connection points dry. Risk of electrocution.
4.3 Safe operation
► Only operate the FiltoMatic CWS if no persons are in the water.
► Never carry or pull the UVC clarifying unit and the dirty water pump of the FiltoMatic CWS by holding
on the connection cables.
► Do not operate defective units. Do not operate the FiltoMatic CWS if the electrical connection cables
are defective. Pull the power plug immediately. The connection cables of the UVC clarifying unit and
of the dirty water pump cannot be repaired. Replace the components. Dispose of the defective
components in compliance with the environmental regulations.
► Never open the housing of the UVC clarifying unit, dirty water pump, control system or their
attendant components, unless this is explicitly mentioned in these instructions of use.
► Only use original spare parts and accessories.
► Never use the system for filtering fluids other than water.
► The radiation of the UVC lamp, even in small doses, is dangerous for eyes and skin. Never operate
the UVC lamp in a defective housing or outside of the housing.
► Never operate the UVC lamp without cleaning rotor, as this also acts as an eye protection against
UVC radiation.
► Overvoltage in the mains could lead to operating malfunctions of the unit. For information, please
refer to chapter "Remedy of faults".