Oase FILTOCLEAR 3.000, FILTOCLEAR 1.600, FILTOCLEAR 800, FILTOCLEAR 4.000 Warranty, Safety And Operating Instructions

1
Warranty, Safety and Operating Instructions
Garantie, mode d'emploi et consignes de sécurité
Garantia, Instructivo de Seguridad y de Operaciones
800 – 1.600 – 3.000 – 4.000
FILTOCLEAR
29746/02C
2
Use these instructions to familiarize yourself with the device before you use it for the first time. It is absolutely essential that you observe the safety guidelines on the proper and safe use of the device. For safety reasons, children and young people under 16 years of age, as well as people who cannot recognize potential hazards or who are not familiar with these instructions, must not use this device! Please keep these instructions in a safe place! In the event of a change of ownership, please pass these instructions on to the new owner along with the product.
Symbols
The symbols used on the device and in these instructions have the following meaning:
Caution! Important advice about hazards! Important information!
Caution! Refer to the instructions! Caution! Disconnect plug!
Keep away from direct sunlight! Caution! Dangerous UVC radiation! The Filtoclear may be used with a maximum pressure of 2,9 psi
(0.2 bar)!
The Filtoclear must be removed when frost is expected!
Water inlet from the pump into the filter.
Water outlet from the filter into the pond.
Cleaning outlet from the filter into the sewerage system or onto a flower bed, for example.
Function switch setting “Filter“. Function switch setting “Clean“.
Pmax = 2,9 psi
(0,2 bar)
English
3
English
Unpacking
When unpacking, if external damage is visible which could impair the functioning of important parts of the equipment, please inform the carrier of the defects immediately , on the same day if possible, and insist on the facts being recorded in writing. Then contact your supplier who will take care of everything else.
Parts supplied
1 x Filtoclear pressure filter with integrated UVC 2 x spiral stepped hose adapter ½“, transparent 1 x spiral stepped hose adapter 1½“, black 1 x spiral stepped hose adapter 1½“, threaded, black 3 x union nuts 1½“ 2 x flow vane 1 x flat seal 1 x instructions
Appropriate use
The Filtoclear with integrated UVC is a sealed pressure filter system for biological and mechanical filtering of normal pond water with a temperature of + 40°F to + 95°F. This Filtoclear pressure filter is intended exclusively for private use for cleaning garden ponds with or without pond fish. Optimum cleaning is achieved in combination with the OASE Aquamax pumps.
Important safety instructions
Warning - T o guard against injury , basic safety precautions should
be observed, including the following:
1. Read and follow all safety instructions
2. Danger - T o avoid possible electric shock, special care should be taken since water is employed in the use of this equipment. For each of the following situations, do not attempt repairs yourself; return the appliance to an authorized service facility for service or discard the appliance.
- lf the appliance falls into the water, DON’T reach for it! First unplug it and then retrieve it. lf electrical components of the appliance get wet, unplug the appliance immediately.
4
English
Safety guidelines
Filtoclear pressure filter with integrated UVC
- Caution: Dangerous ultraviolet radiation. The rays from
the UVC lamp are harmful to your eyes and skin! Never
operate the lamp of the Filtoclear UVC outside the casing!
- Set up the Filtoclear with integrated UVC so that it is safe from flooding. Secure your Filtoclear so that it will not fall into the pond. It should be placed at least 6,5 feet from the edge of the pond.
- Always turn the pump on first before starting up the Filtoclear UVC. The UVC lamp must not be operated without water flowing through it.
- Do not use the Filtoclear UVC if the connecting lead, UVC lamp or casing appear to be defective!
- Do not use the Filtoclear UVC when there are people in the water!
- Caution: The built-in temperature monitor in the Filtoclear UVC automatically switches off the UVC lamp if it overheats. After it has cooled down, the UVC lamp is automatically switched back on again.
- Never open the casing of the UVC or its accessories unless expressly directed to do so in the instructions.
- The electrical data of the supply grid must correspond to the data on the type label.
- Do not operate any appliance if it has a damaged cord or
plug, or if it is malfunctioning or if it is dropped or damaged in any manner .
3. Always unplug an appliance from an outlet when not in use,
before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
4. Do not use an appliance for other than intended use. The use
of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
5. Read and observe all the important notices on the appliance.
6. Save these instructions
5
English
P
max
= 2,9 psi (0,2 bar)
min
6,5
feet
max.
6,5 feet
- Always disconnect the plugs of the Filtoclear UVC and of all devices that are in the water before you carry out any work on the Filtoclear!
- For your own safety, contact an electrician if you have any questions or problems regarding the electrical connection!
- Never immerse the device in water!
- Electrical installations near garden ponds and swimming pools must comply with international and national installation guidelines.
- Keep the connecting points dry!
- Do not carry or pull the Filtoclear by its connecting lead! Protect the connecting lead from heat, oil and sharp edges.
- Lay the hoses and connecting lead in such a way that they are not an obstacle and do not become damaged!
- Caution! Danger! Never operate the Filtoclear pressure filter with integrated UVC with a water pressure greater than 2,9 psi ( 0,2 bar)! The height difference between the filter lid and the pressure-free outlet point can therefore be 6,5 feet max. The maximum delivery pressure of the pump being used must not exceed 7,25 psi ( 0,5 bar).
- Only operate the Filtoclear with pressure hoses that are approved for at least 2,9 psi ( 0,2 bar), i.e. the maximum pressure of the pump.
- Check and clean the water outlet to the pond on a regular ba­sis. The outlet should always be clear , as any blockage would result in the filter being operated at a pressure greater than 2,9 psi ( 0,2 bar). This in turn would lead to the risk of leaking and therefore of the pond emptying completely .
- Important: When the Filtoclear is being used in ‘filter’ mode, the cleaning connection or any drainage hose connected to it must always be sealed with the sealing cap and inserted flat seal in order to prevent the pond from emptying. At the same time the sealing cap acts as a safeguard in case the function switch is accidentally set to ‘Clean’.
- Make sure that the function switch is always set to ‘Filter’ when the pump is in operation. The function switch may only be set to ‘Clean’ when cleaning the filter sponges with the handle function.
6
English
Do’s
Make sure that the unit is installed in accordance with all
National and Electrical Codes.
Make sure to install the Filtoclear at least 6,5 feet from the
edge of the pond. — Make sure to keep the outlet system free of dirt and debris. — Make sure to unplug the unit before servicing the unit. — Make sure to keep the plugs and connections dry at all times.Make sure to return the unit to an authorized service dealer
for any repairs.
Don’ts
Do not exceed the “Maximum Operating Pressure” of 2,9 psi
( 0,2 bar). — Do not carry or pull the unit by the power cord. — Do not tamper with or operate unit without the proper ground-
ing plug. — Do not operate the unit if the power cord appears to be defective.Do not operate the lamp outside of the housing.Do not operate the unit without water flowing through the unit.Do not expose eyes or skin to the lamp’s rays. — Do not attempt any repairs on this unit.Do not open the casing of the Bitron or its accessories un-
less expressly directed to do so in the instructions
- Before starting up the Filtoclear, check that the connected
hoses, the sealing cap and the tension ring with safety latch are sitting correctly .
- Never pump any liquids other than water!
- When frost is expected, you must remove the Filtoclear with
integrated UVC.
- Install the Filtoclear where it will not be exposed to direct
sunlight.
- Please observe the local noise protection regulations.
7
English
Electrical connection
Grounding instructions
This product must be grounded. If it should malfunction or break­down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with an electrical cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Danger – Improper connection of the equipment-grounding
conductor can result in the risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with the product.
Warning – To reduce the risk of electrocution, keep all connec­tions dry and off the ground. Do not touch plug with wet hands.
Ground fault circuit interrupter (GFCI) protection
T o comply with the National Electric Code (NFPA 70) and to pro­vide additional protection from the risk of electrical shock, this unit should only be connected to a receptacle that is protected by a ground fault circuit interrupter (GFCI < 30 mA).
8
English
How the Filtoclear pressure filter works
The Filtoclear pressure filter with integrated UVC is a sealed filter system for the biological and mechanical cleaning of pond water.
A Water inlet
The pump is connected to the water inlet with a pressure hose.
B Pre-clarifying of pond water
As the water flows in, it is briefly exposed to ultraviolet radiation
under the UVC lamp. This kills off germs and bacteria and
inhibits algae growth. The water subsequently flows from the
edge into the filter in a circular fashion.
C Vortex system (settling zone)
Suspended matter and bio-sludge are precipitated by the
centrifugal effect and gravity.
D Mechanical filtering
Dirt particles are trapped by the outer surface of the filter
sponges before the water flows the entire height of the filter from
the edge into the inner chamber of the filter.
GI H
F
A
C
D
E
B
J
9
Installation guidelines with regard to the Clear Water Guarantee
OASE guarantees that this system will maintain clear water in a pond in accordance with the following definitions, installation and usage guidelines:
Definition of clear water:
Clear water is achieved if the fish or stones at the bottom of the pond can be seen at a depth of 3,25 feet.
Selecting the right system
Please select the filter system using the following table (selection criteria: pond size and with/without fish population).
E Biological clarifying
The pores of the filter sponges form a large inner surface which microorganisms can colonise. The red and blue filter sponges differ in size and density. This creates zones in which the water can flow at different speeds. Zones with a high flow speed (blue filter sponges) favour the colonisation of microorganisms which convert ammonium to nitrate via nitride (nitrification). Zones with a low flow speed (red filter sponges) support the colonisation of anaerobic microorgan­isms which reduce nitrate to nitrogen (denitrification).
F Water outlet with flow indicator
At the water outlet, the clarified water is fed back into the garden pond via a pressure hose or a watercourse etc.
G Cleaning connection
When cleaning the filter, a drainage hose can be connected to the cleaning connection which diverts the dirty water into a drain or onto a flower bed.
H Function switch
The function switch is used to switch between normal water discharge into the pond (“Filter“) and the cleaning connec­tion (“Clean“).
I Cleaning the filter sponges with the handle function
The filter sponges can be cleaned while the Filtoclear is operational through hard “pumping” by pressing the cleaning handle.
J UVC Reflection (only Filtoclear 4.000)
English
10
The filter system with integrated UVC must be running permanently , 24 hours a day . The UVC lamp must be replaced after 8,000 hours of operation in order to ensure that the Filtoclear UVC continues to operate with optimum effectiveness. The filter system must be cleaned regularly .
Pressure loss due to height difference
The selection table allows for a maximum height difference of 3,25 feet between the surface of the water and the highest point of the filtering system. If the height difference is greater than 3,25 feet, you should use a correspondingly more powerful pump.
English
Pressure loss due to hoses
Use large hoses if possible in order to minimise pressure loss. Please use the following hose diameters for hoses up to 13 feet in length:
Filtoclear 800 1 – 1¼ inches Filtoclear 1.600 1 – 1½ inches Filtoclear 3.000 1¼ - 1½ inches Filtoclear 4.000 1½ inches
1''
1 ¼'' 1 ½''
¾“
Slight pollution of pond without fish population
Heavy pollution of pond with fish population
Aquamax Filtoclear 800 Filtoclear 1.600
1.600 SF 800 gal 400 gal 1.050 gal 525 gal
2.200 SF - - 1.600 gal 800 gal
3.000 SF - - - -
3.500 SF - - - -
Aquamax Filtoclear 3.000 Filtoclear 4.000
1.600 SF 1.600 gal 800 gal 2.100 gal 1.050 gal
2.200 SF 2.100 gal 1.050 gal 2.400 gal 1.200 gal
3.000 SF 2.640 gal 1.320 gal 3.000 gal 1.500 gal
3.500 SF 3.000 gal 1.500 gal 4.000 gal 2.000 gal
11
English
Installing and connecting the Filtoclear pressure filter
Installing the Filtoclear pressure filter
Choose a suitable location for the pressure filter. Please note the installation guidelines regarding the clear water guarantee as well as the following guidelines: – Install the Filtoclear pressure filter with integrated UVC so that
it is safe from flooding. Secure your Filtoclear so that it will not
fall into the pond. It should be placed at least 6,5 feet from the
edge of the pond. – Place the filter on a firm and level base, e.g. on a slab. The filter
can also be buried up to the lip of the filter canister. – Please ensure that there is unhindered access to the lid in
order to be able to carry out work on the filter, e.g. cleaning the
filter sponges. – Never operate the Filtoclear pressure filter with integrated
UVC with a water pressure greater than 2,9 psi ( 0,2 bar). The
height difference between the lid and pressure-free outlet can
therefore be a maximum of 6,5 feet.
Connecting hoses
Decide which hose diameter you need based on the selection table and the recommended hose according to the installation guidelines for the clear water guarantee (page 9 and 10). Only operate the Filtoclear with pressure hoses that are approved for a pressure of at least 2,9 psi ( 0,2 bar) i.e. the maximum pressure of the pump. From the OASE range, we recommend the green spiral hose with the corresponding hose clip. Note: We recommend warming the hose with hot water , pushing / twisting it onto the spiral stepped hose adapter and securing it with a hose clip. This makes the connection more watertight. Important!: To avoid pressure loss, cut the spiral stepped hose adapter at the relevant point to fit each hose (see illustration).
1'' 1 ¼''
1 ½''
¾“
P
max
= 2,9 psi (0,2 bar)
min
6,5
feet
max.
6,5 feet
For hoses that are longer than 13 feet, please always use hoses that correspond to the upper value of the scale. In order to avoid pressure loss, cut the spiral stepped hose adapter at the relevant points for each hose. Avoid unnecessary corners and bends which contribute to further pressure loss.
12
English
Connecting to cleaning connection
You can have a drainage hose permanently connected to the cleaning connection. This allows you to drain the dirty water directly into the sewerage system or onto a flower bed. Important!: When the Filtoclear is being used in ‘filter’ mode, the cleaning connection or any drainage hose connected to it must always be sealed with the sealing cap and inserted flat seal in order to prevent the pond from emptying. At the same time the sealing cap acts as a safeguard in case the function switch is accidentally set to ‘Clean’. To connect the drainage hose, push the union nut onto the transparent spiral stepped hose adapter. Push / twist the hose on and secure with a hose clip. Insert the green flow vane into the union nut and screw tight onto cleaning connection. In order to be able to seal the open end of the drainage hose with the sealing cap, you need to push / twist the black spiral stepped hose adapter with thread onto the hose and secure it with a hose clip. Screw the sealing cap and inserted flat seal on tight.
Connection to water outlet
Push the union nut onto the transparent spiral stepped hose adapter. Push / twist the hose on and secure with a hose clip. Insert the green flow vane into the union nut and screw tight onto the water outlet nozzle. Note: We recommend diverting the cleaned water via a small watercourse, for example, instead of feeding it directly back into the pond. This enriches the water with additional oxygen.
Connection at water inlet
Push the union nut onto the black spiral stepped hose adapter . Push / twist the hose on and secure with a hose clip. Insert the flat seal into the union nut and screw tight onto the water inlet nozzle:
13
English
Starting up the pressure filter
Important! Before each start-up, you should check that the
connected hoses, the sealing cap and the tension ring with safety latch are sitting correctly . The function switch must be set to the “Filter“ symbol. It is imperative that you read and follow the safety guidelines before start-up.
1. First switch on the pump Caution! The UVC lamp must not be operated without water flowing through it.
2. After starting up the pump, check that all the connections are watertight. Improve those that are not.
3. Plug the Filtoclear UVC into the mains. The power indicator lights up with a blue shimmer .
Note: In the case of a new installation, the pressure filter only reaches its full biological cleaning effectiveness after a few weeks. Extensive bacterial activity only starts at temperatures of + 50°F or above.
Cleaning and maintenance of the Filtoclear
The Filtoclear pressure filter is largely maintenance-free. The fil­ter sponges should, however, be cleaned regularly .
Cleaning the filter sponges with the handle function
Suspended matter and dirt are deposited in the filter sponges over time. These deposits reduce the effectiveness of the filter, so the filter sponges should be cleaned regularly , e.g. every two weeks.
Note: The filter sponges should be cleaned when cloudy or even dirty water flows out of the water outlet and back into the pond. You can check how dirty the filter is at the transparent spiral stepped hose adapter with the green flow vane at the water outlet.
1. T wist off the sealing cap at the cleaning connection or at the drainage hose that is connected to the cleaning connection. Caution: There will be a small flow of water .
2. Pull the function switch up slightly and turn clockwise until it clicks into the “Clean” position.
3. Pull the cleaning handle hard and “pump” several times. This squeezes the filter sponges and cleans them mechanically .
4. Press the cleaning handle down until it hits the lid. The two O-rings noticably lock into position.
14
English
5. The filter will now be rinsed clean. As soon as only clean water can be seen through the transparent spiral stepped hose adapter at the cleaning connection, pull the function switch up slightly and turn anti-clockwise until it clicks into the “Filter” position.
6. Screw the sealing cap with the inserted flat seal tight onto the cleaning connection or the drainage hose that is connected to the cleaning connection.
7. The filter is now operational again. Check the water flow into the pond at the green flow vane.
Washing the filter sponges
If the water flow is too small due to dirty filter sponges and cannot be improved through cleaning with the handle function, then the filter sponges must be washed or replaced. Note: Do not use any chemical cleaning agents so as not to kill off the microorganisms in the filter sponges.
1. Disconnect the mains plug of the Filtoclear UVC.
2. Switch off the pump and ensure that it cannot be switched on unintentionally.
3. Remove all hoses by unscrewing the union nuts.
4. Remove the tension ring. T o do this, pull back the safety latch, push in the fastening hook and open the tension ring.
5. Lift off the lid with the filter sponge assembly. Place the lid upside down on another clean surface. The filter sponges are lying with the filter plate facing up.
Wear marking:
The filter sponges are pre-stressed. The filter sponges can fall apart due to the mechanical strain and due to normal ageing. This can result in a short-circuit in the filter . To check the filter sponges, they must lie on top of each other on the lower filter plate without any “air gaps”. The filter sponges must be replaced if the wear marking on the upper plate is completely visible (see illustrations)
6. Remove upper filter plate by unscrewing the two screws.
7. Pull off the filter sponges and clean under flowing water. Give the filter sponges a good squeeze.
15
8. Pull off the lower filter plate.
9. Clean the filter box, the lid with lattice pipe, both filter plates and the tension ring by spraying them with a water hose.
10.Lift the bypass valve slightly and clean the inlet comb of the Filtoclear UVC (see illustration).
1 1.Clean the lid sealing ring and the edge of the filter box.
12.Push one filter plate, with the collar facing up, onto the lattice pipe and the cleaning rods.
13.The filter sponges are pushed on from the casing lid, starting with a large blue filter sponge and always alternating with a small red filter sponge. The cleaning rods lie in the two openings of the large chamber of the filter sponges.
14.Put the filter plate on with the collar facing down. Fasten the cleaning rods flush to the filter plate using the two screws. Important: If the cleaning rods can be pushed through the holes of the filter plate, the filter plate must be turned 90° onto the other set of holes. The lattice pipe must be completely covered by the collar diameter .
15.Place the lid seal onto the upper edge of the filter box (see illustration).
16.Press the lid with the filter sponge assembly onto the filter box.
17.Place the tension ring onto the edge of the filter box and lid, press down on the lid and click the fastening into place. Push the safety latch in. Caution: Do not jam the cable of the Filtoclear UVC!
18.Fasten all hoses with flat seals or flow vane to the corresponding connections by screwing the union nuts on tight.
19.Start the pressure filter up again. (see “S tarting up the pressure filter“)
English
16
Replace UVC lamp
The UVC lamp must be replaced after 8.000 hours of operation in order to ensure that the Filtoclear UVC continues to operate with optimum effectiveness.
1. Disconnect the mains plug of the Filtoclear UVC.
2. Switch off the pump and make sure that it cannot be switched on unintentionally .
3. Unscrew the four screws of the Filtoclear UVC and carefully pull the lamp from the lid of the filter. Note: The screws are screwed in very deep (approx. 0,7 inch) in order to allow greater torque to be applied.
4. Unscrew the clamping screw in an anti-clockwise direction and remove the quartz tube with O-ring.
5. Pull out the UVC lamp and replace it.
Note: Due to a built-in safety switch the UVC lamp only works after complete assembly of the Filtoclear. Only lamp s of the type 9W UV -C, G23 may be used.
6. Clean the quartz tube with a damp cloth.
7. Check the quartz tube and O-ring for damage and replace if necessary.
8. Screw the clamping screw with quartz tube and O-ring on tight in a clockwise direction.
Cleaning the quartz tube
1. Disconnect the mains plug of the Filtoclear UVC.
2. Switch off the pump and make sure that it cannot be switched on unintentionally .
3. Unscrew the four screws of the Filtoclear UVC and carefully pull the lamp from the lid of the filter. Note: The screws are screwed in very deep (approx. 0,7 inch) in order to allow greater torque to be applied.
4. Clean the quartz tube with a damp cloth.
5. Pull out the flat seal and the protective tube between the lid and the Filtoclear UVC and clean with water. Check the parts for damage and replace if necessary . Fit the flat seal under the ring of the protective tube (see illustration) and insert in lid together .
6. Insert the Filtoclear UVC in the lid of the filter and screw the four screws on tight by hand (1,5 ft-lb).
7. Start the pressure filter up again. (see “S tarting up the pressure filter“)
English
17
English
9. Pull out the flat seal and the protective tube between the lid and the Filtoclear UVC and clean with water. Check the p arts for damage and replace if necessary . Fit the flat seal under the ring of the protective tube (see illustration) and insert in lid together .
10.Insert the Filtoclear UVC in the lid of the filter and screw the four screws on tight by hand (1,5 ft-lb).
1 1 .S tart the pressure filter up again. (see “S tarting up the
pressure filter“).
Storage / winter storage
When frost is expected, you must remove the Filtoclear with integrated UVC! Clean it thoroughly (see Cleaning and maintenance of the Filtoclear). Check the Filtoclear with integrated UVC for any damage. Store the Filtoclear with integrated UVC in a dry and frost-free place. The place of storage must be inaccessible to children.
Advice on disposal
Please dispose of your Filtoclear with integrated UVC in an environmentally friendly way. Contact your local refuse depart­ment for advice on disposal. UVC lamps must not be disposed of with domestic waste! Remove the UVC lamp from the unit and take it to a collection point, so that it can be disposed of in an environmentally responsible way .
Repair / cable replacement
For repair / cable replacement please send the defective Filtoclear with integrated UVC directly to the supplier / manufacturer . Available spare part s are listed under Product overview.
18
Fault
Water not getting clear
UVC lamp indicator is not on
No water discharge from pond inlet
Possible causes
• Unit not been used for long
• Inappropriate pump capacity
• Water is extremely dirty
• Fish and animal population too large
• Filter sponges are dirty
• Quartz tube is dirty
• Mains plug of Filtoclear UVC not connected
• Defective UVC lamp
• Faulty connection
• Lamp has no UVC output
• Protective tube not fitted
• Filtoclear UVC over­heating
• Function switch set to “Clean”
• Mains plug of pump not connected
• Pond inlet blocked
Measures
• Full biological cleaning effectiveness is only reached after a few weeks.
• Reset pump capacity
• Remove algae and leaves from the pond, change the water
• Guideline: approx. 2 feet fish length to every 265 gal of pond water
• Clean the filter sponges
• Remove the Filtoclear UVC and clean the quartz tube
• Connect the mains plug of the Filtoclear UVC
• Replace the UVC lamp
• Check the electrical connection
• The lamp should be replaced after approx. 8,000 hours of operation
• See Replace UVC lamp
• After cooling down, UVC switched on automatically
• Reset function switch to “Filter”
• Connect the mains plug of the pump
• Clean pond inlet
Troubleshooting
English
Technical data
Filtoclear 800 1.600 3.000 4.000
Dimensions in inches (LxWxH) 14,96x14,96x12,2 14,96x14,96x17 14,96x14,96x21,6 14,96x14,96x26,4
Inlet and outlet ¾“ to 1½“ ¾” to 1½“ ¾“ to 1½“ ¾“ to 1½“ Filter volume in gallon 1,3 2,4 3,7 4,5 Crystalline filter surface 57 ft² 113 ft² 170 ft² 225 ft² Integrated UVC clarifier 9 W 9 W 9 W 9 W Nominal voltage UVC 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz Lamp components UVC 9W UV-C, G23 9W UV-C, G23 9W UV-C, G23 9W UV-C, G23 Cable length 15 ft 15 ft 15 ft 15 ft
Weight 11 lbs. 12 lbs. 13 lbs. 14 lbs.
19
English
Wearing parts
Filtoclear 800: Spare UVC lamp 9W ID No.54984
S pare filter set Filtoclear USA 800 ID No.56109 S pare set of seals ID No.34581
Filtoclear 1.600: Spare UVC lamp 9W ID No.54984
S pare filter set Filtoclear USA 1.600 ID No.56110 S pare set of seals ID No.34581
Filtoclear 3.000: Spare UVC lamp 9W ID No.54984
S pare filter set Filtoclear USA 3.000 ID No.5611 1 S pare set of seals ID No.34581
Filtoclear 4.000: Spare UVC lamp 9W ID No.561 12
Spare filter set Filtoclear USA 4.000 I D No.56884 Spare set of seals ID No.34581
Product overview
1 Filter box Filtoclear USA 800 ID N o . 24460 2 Filter box Filtoclear USA 1.600 ID No . 24461 3 Filter box Filtoclear USA 3.000 ID No . 24462 4 Filter box Filtoclear USA 4.000 ID No . 26527 5 Lid Filtoclear ID N o .24459 6 Inner lid Filtoclear ID N o. 24457 7 Spare UVC lamp 9W ID No . 54984 8 Filtoclear UVC 120V/60Hz ID N o. 25236 9 Quartz tube ID N o .22622 1 0 Lattice pipe Filtoclear USA 800 ID N o . 24853 11 Lattice pipe Filtoclear USA 1.600 ID N o .24854 1 2 Lattice pipe Filtoclear USA 3.000 ID No . 24852 1 3 Lattice pipe Filtoclear USA 4.000 ID N o .26595 1 4 Protective tube Filtoclear UVC ID N o. 34521 1 5 Spare set of control elements Filtoclear ID N o . 34579 1 6 Spare set of screw elements Filtoclear ID No . 34580 1 7 Spare set of seals Filtoclear ID No . 34581 1 8 Spare filter set Filtoclear USA 800 ID N o .56109 1 9 Spare filter set Filtoclear USA 1.600 ID N o. 56 1 1 0 2 0 Spare filter set Filtoclear USA 3.000 ID N o. 56 1 11 2 1 Spare filter set Filtoclear USA 4.000 I D N o. 56884 2 2 Cleaning rods Filtoclear USA 800 I D N o. 24749 2 3 Cleaning rods Filtoclear USA 1.600 I D N o. 24748 2 4 Cleaning rods Filtoclear USA 3.000 I D N o. 24747 2 5 Cleaning rods Filtoclear USA 4.000 I D N o. 26596 2 6 Additional pack Filtoclear USA
800 / 1.600 / 3.000 / 4.000 ID No.34617
2 7 T ension ring Filtoclear ID No.34578 2 8 Protective tube with reflector plate (4.000 only) ID No.35256
20
English
5
6
7/ 8
9
10
17
17/18
27
18/27
16
16/18
16(2x)/17(12x)
25
18/27
17(12x)
18
17
17
18
17
17/18
17
18
15a/15b/28
18
18
21
English
1/2/3/4
11/12/13/14
16/17
16
19/20/21/22
18
23/24/25/26
19/20/
21/22
18
28
16/18
17