All rights are reserved. No part
of this document may be
photocopied, reproduced or
translated to another language
without prior written consent
of OAKWORKS®, Inc.
OAKWORKS® is a registered
trademark of OAKWORKS®, Inc.
Notice
The information contained within this
document is subject to change
without notice and should not
be construed as a commitment by
OAKWORKS®, Inc.
OAKWORKS®, Inc. encourages requests
for technical specifications and the
like documentation to ensure accuracy. The appropriate documentation
is available upon request.
OAKWORKS®, Inc. shall not be
liable for incidental or consequential
damages in connection with or arising
out of the furnishing, performance, or
use of this document and the program
material which it describes.
TABLE OF CONTENTS
Product Use Description ..............................................................................................................................1
Important Safety Instructions
Symbol Identification .........................................................................................................................1
Warranty Information ..................................................................................................................................17
Model Number & Serial Number ..............................................................................................................18
Contact Information ....................................................................................................................back cover
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS
PRODUCT USE DESCRIPTION
The PF Exam Table is a powered positioning table used for routine treatment and examination procedures.
It is intended to be operated by a healthcare professional in a medical environment. No special training is
required but a review of the following User Manual is important for the safety of the operator and patient.
The healthcare professional should read and understand this entire manual before use with a patient. There
are no known contraindications with the use of this equipment.
SYMBOL IDENTIFICATION
This symbol, when used in this manual and on product labels, represents a caution
warning. Be sure to read and comply with all precautions and warnings.
This symbol, when used in this manual and on product labels, warns against an
electrical shock hazard. Be sure to observe and comply with all warnings.
This symbol, when used in this manual or on product labels, indicates a Protective Earth
(Ground) Terminal.
This symbol, when used in this manual or on product labels, indicates that the
product should be protected from moisture. The humidity specifications for Transport &
Storage are listed in the environmental conditions section of this manual.
This symbol is used to indicate that the operator should consult the user manual.
This symbol, when used in this manual and on product labels, indicates that the table and
components are a Type B Applied Part pursuant to IEC 60601-1: 2005.
This symbol, when used in this manual or on product labels, indicates alternating
~
----
current (AC).
This symbol, when used in this manual or on product labels, indicates direct current
(DC).
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
The Backrest and Leg Rest sections are not designed to support the entire weight of the patient. Do not sit on the Backrest or
Leg rest sections.
READ AND SAVE THESE INSTRUCTIONS
The table is not to be used as a gurney or to transport patient from room to room.
Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to
the EMC information provided in this manual.
Portable and mobile RF communications equipment can affect Medical Electrical Equipment.
1
IMPORTANT SAFETY INSTRUCTIONS
The use of accessories, transducers, and cables other than those specified by the manufacturer, may result in increased emissions or
decreased immunity of the table.
The table should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the table should
be observed to verify normal operation in the configuration in which it will be used.
The table is designed to be a stand alone table. This table must not be modified or incorporated into any other equipment.
As with any moving mechanism there are potential pinch points around and underneath the table top. It is the responsibility of the operator of this equipment to insure that bystanders are not in the area below or around this equipment during
operation.
Proper operation of this equipment is very important for the safety of the operator, patient, and any other individuals in the
area of this equipment. Directions for use of this equipment are described in this manual. The operator should read these sections carefully.
Weight Limit: (patient and accessories) 550 lbs./250 kg. Do not exceed.
Be certain that the table is completely lowered without any tilt being present prior to discharging an ambulatory patient.
The patient may lose balance and fall.
This table is not suitable for use in the presence of flammable anesthetic mixture with air or oxygen or nitrous oxide.
Do not lift the table by the table top. This can damage the table.
When lowering the table or using the Trendelenburg functions, make sure there is nothing underneath the table top that
can impede motion (like stools, cabinets, accessory parts, cleaners, etc.).
Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by
the manufacturer.
Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
WARNING
To reduce the risk of burns, fire, electric shock or injury to persons:
1. Unplug this furnishing from the electrical outlet before cleaning.
2. Unplug from outlet before adding or removing parts.
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or dropped into water. Contact Oakworks Customer Service before use.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
DANGER
Risk of electric shock - Connect this furnishing to a properly grounded outlet only. See Grounding Instructions in this
manual.
Electrical Shock Hazard. The power supply/control module is located under the table seat. No user serviceable parts are inside
the control box. Refer servicing to qualified personnel. Unplug wall plug prior to contact with any cables connected to the
power supply.
Table Capacity550 lbs. (250 kg.) (patient and accessories)
Widths
Length - 2 section74” (188 cm.)
Padding3” (8 cm.) Comfort Foam™
UpholsteryTerra Touch™
Wood StainNatural Maple Finish
Table Weight
Warranty3 year parts, 1 year labor
Safety Listings
*
100V/60Hz - 230V/50Hz Switch Mode Power
Supply
27” (69 cm.), 29” (74 cm.), 31” (79 cm.) or 33”
(84 cm.)
212 lbs. (96 kg.)
FDA, cETLus
Shown with optional
wood finish
OPTIONS
4” (10 cm.) Comfort Foam™
Wood Finishes
Locking Casters
Hand Control
ACCESSORIES
QuickLock Face Pad
Table Extender - 12” (30.5 cm.) Long
Lowered Arm Rest
For electrical specs, see Specifications section.
4
PRODUCT DESCRIPTION
PF200
Electric Lift
Towers (2)
QuickLock™ Face
Pad (option)
Accessory
outlets (2)
Foot Control
STANDARD SPECIFICATIONS
Motion 1Powered 19.5”-35.5” (50-90 cm.) Height Range
Motion 2
Foot ControlAll powered motions
Table Voltage Options
Table Capacity550 lbs. (250 kg.) (patient and accessories)
Widths
Length - 2 section73” (185 cm.)
Padding3” (8 cm.) Comfort Foam™
UpholsteryTerra Touch™
Wood StainNatural Maple Finish
Table Weight
Warranty3 year parts, 1 year labor
Safety Listings
*
Powered ±15º Trendelenburg/ Reverse
Trendelenburg
100V/60Hz - 230V/50Hz Switch Mode Power
Supply
27” (69 cm.), 29” (74 cm.), 31” (79 cm.) or 33”
(84 cm.)
212 lbs. (96 kg.)
FDA, cETLus
Shown with optional
wood finish
OPTIONS
4” (10 cm.) Comfort Foam™
Wood nishes
Locking Casters
Hand Control
ACCESSORIES
QuickLock Face Pad
Table Extender - 12” (30.5 cm.) Long
Lowered Arm Rest
For electrical specs, see Specifications section.
5
INSTALLATION
All tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is
rated for the table. (see Grounding below)
Arrange the power cord and control cords so that they will not create a tripping hazard and where
the controls are located to your liking and are conveniently accessible.
Be sure access to plug is not blocked for disconnecting the table from power.
GROUNDING
DANGER
This product must be grounded. If it should malfunction or break down, grounding
provides a path of least resistance for electrical current to reduce the risk of electric
shock. This product is equipped with a cord having an equipment-grounding conductor
and a grounding pin. The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. See U.S.
sample below.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to
whether the product is properly grounded. Do not modify the plug provided with the
product - if it will not fit the outlet; have a proper outlet installed by a qualified electrician.
Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only.
Grounding Methods
Correct Implementation
Incorrect Implementation
6
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.