1st Edition, October 2007
2nd Edition, March 2008
3rd Edition, February 2009
4th Edition, September 2009
Printed in U.S.A.
All rights are reserved. No part of this
document may be photocopied, reproduced
or translated to another language without prior
written consent of OAKWORKS®, Inc.
OAKWORKS® is a registered
trademark of OAKWORKS®, Inc.
Notice
The information contained in this document
is subject to change without notice and
should not be construed as a commitment by
OAKWORKS®, Inc.
OAKWORKS®, Inc. assumes no responsibility for
any errors that may appear in this document nor does it make expressed or implied
warranty of any kind with regard to this
material, including, but not limited to, the
implied warranties
of merchantability and fitness for a
particular purpose.
OAKWORKS®, Inc. shall not be liable for incidental or consequential damages in connection with or arising out of the furnishing,
performance, or use of this document and
the program material which it describes.
TABLE OF CONTENTS
Symbol Identification ........................................................................... pg 1
(Equipment that is NOT life supporting) ................................ pg 31
Contact Information .................................................................. Back Cover
View complete warranty details at www.oakworks.com
All warranties are limited to factory-provided replacement parts, factory repair or replacement, at the discretion of OAKWORKS®. OAKWORKS® only covers parts and labor on field
repair of stationary products.
All warranties exclude damage caused by improper set-up, accident, abuse, misuse, neglect,
use for other than intended purpose or reasonable wear such as tears in the upholstery.
All warranties are invalidated by non-factory modifications and unauthorized repairs, which
will immediately terminate all liability by OAKWORKS® for the product or damages caused by its
use.
The buyer and its customers shall be responsible for proper set-up and use of the products
as well as any supervision required for safety. In no event shall OAKWORKS® be liable for any
special, indirect, consequential, incidental, exemplary or punitive damages or costs. Use of
non-approved cleaning solutions voids the guarantee on all fabrics.
The warranties set forth herein are the sole and exclusive warranties provided by
OAKWORKS®. There are no other warranties, representations or guarantees provided by
OAKWORKS® either expressed or implied, including warranties of merchantability and fitness
for a particular purpose. Warranty valid with proof of purchase.
SYMBOL IDENTIFICATION
The OAKWORKS® Fluoroscopy Table is a radiographic table intended for use with
mobile or compact stationary C-arm Fluoroscopy Systems. It is ideally suited for
pain management imaging and therapeutic procedures.
This symbol, when used in this manual and on product labels, represents a caution
warning. Be sure to read and comply with all precautions and warnings.
This symbol, when used in this manual and on product labels, warns against an
electrical shock hazard. Be sure to observe and comply with all warnings.
This symbol, when used in this manual and on product labels, indicates the potential
of exposure to harmful x-rays. Be sure to read and comply with all warnings.
This symbol, when used in this manual and on product labels, indicates that the
table and components are a Type B Applied Part pursuant to IEC 601.1 and EN
60601-1: 1990.
SYMBOL IDENTIFICATION
SYMBOL IDENTIFICATION
~
This symbol, when used in this manual or on product labels, indicates a Protective
Earth (Ground) Terminal.
This symbol when used in this manual or on product labels, warns that during transport there should be no stacking of containers.
This symbol, when used in this manual or on product labels, indicates that
the product should be protected from moisture. The humidity specifications for
Transport & Storage are listed on page 23.
This symbol, when used in this manual or on product labels, indicates that information is
given regarding the recommended temperature limits during transport and storing.
This symbol, when used in this manual or on product labels, indicates the date of
manufacture of the device.
This symbol, when used in this manual or on product labels, indicates alternating
current (AC).
This symbol, when used in this manual or on product labels, indicates direct current (DC).
----
1
WARNINGS / PRECAUTIONS
WARNINGS / PRECAUTIONS
INDICATIONS
The OAKWORKS Fluoroscopy CFPM tables are indicated for use with mobile or
compact C-arm Fluoroscopy Imaging Systems where the x-ray generator is located
below the tabletop. These tables are suitable to use for diagnostic x-ray imaging and
imaging during therapeutic procedures such as spinal injections,
vertebroplasty procedures and other pain management procedures. These tables
may be used for surgical and non-surgical procedures.
CONTRAINDICATIONS
The OAKWORKS Fluoroscopy Table should not be used with Fluoroscopy systems
having intensifier screens or film cassettes larger than 12 inches (30 cm) when an
oblique angle of view is being used.
WARNINGS / PRECAUTIONS
The table is not designed for and should not be used with Magnetic Resonance
Imaging procedures.
WARNINGS
Improper use of this device can cause injury. Be sure to read all operating
instructions prior to use.
Weight limit (patient and accessories): Carbon Fiber Top: 227 kg / 500 lbs. distribured evenly
Do not sit beyond warning line on carbon fiber top.
Lock casters when mounting and dismounting.
The table utilizes four locking casters to permit movement of the table
within the imaging suite. Accidental movement of the table may occur. Lock
casters prior to accomplishing imaging of the patient.
There may be pinch points under the table top. Do not have any body part under
the top when the table is in motion.
Be certain that the table is completely lowered prior to discharging an ambulatory
patient. The patient may lose balance and fall. (CFPM100 & 400 only)
The CFPMFXH is a fixed height table. It is recommended that all patients are assisted
onto the table (physical assistance & step stools with side rails is recommended.)
Patient Safety Strap must be secured prior to using the Trendelenburg/Reverse
Trendelenburg function. (CFPM400 only)
2
WARNINGS: (CONTINUED)
WARNINGS: (cont.)
Electrical Shock Hazard. (CFPM100 & 400 only) The power supply/control module is located inside lifting column and under the top. No user serviceable parts are
inside. Refer servicing to qualified personnel. Unplug wall connector prior to contact with any cables connected to the power supply.
Medical Electrical Equipment needs special precautions regarding EMC and needs
to be installed and put into service according to the EMC information provided in
the Accompanying Documents. (CFPM100 & 400 only)
Portable and Mobile RF Communications Equipment can affect Medical Electrical
Equipment. (CFPM100 & 400 only)
The CFPM100 & 400 (only) should not be used adjacent to or stacked with other
equipment due to the risk of electronic interference. If adjacent or stacked use is
necessary, the table should be observed to verify normal
operation in the configuration in which it will be used.
WARNINGS / PRECAUTIONS
WARNINGS / PRECAUTIONS
The potential of exposure to harmful x-rays exists when this table is in use. The
use of adequate x-ray barrier devices is necessary to provide protection to both
the operator and the patient. X-ray barrier devices are recommended for the patient
outside of the intended target area to prevent exposure to scattered radiation from
the x-ray generating source.
The tabletop has a typical aluminum filtration equivalence of .62 mm as measured
at 100 kVp and a half-value layer (HVL) of 2.7 mm. (1.10 mm as measured at 100
kVp and a half value (HVL) of 3.6 mm)
• The OAKWORKS Fluoroscopy Table may be used for x-ray imaging where the x-ray generator is located below the tabletop and the image receptor is located above the tabletop. This is the recommended method. This table may also be used for x-ray imaging where the x-ray
generator is located above the tabletop and the image receptor is located
below the tabletoop. This application will result in greater patient
exposure to x-rays. The operator must weigh this issue with the imaging
requirements and patient exposure issues.
• The Fluoroscopy Table may be used with the x-ray generator above the tabletop and a film cassette located on the tabletop.
• The x-ray generator should never be located above the tabletop when the O
Positioning System/Prone Pillow are used together. This type of use
requires that the x-ray generator is located below the tabletop and the
imaging intensifier or film cassette located above the tabletop.
AKWORKS Fluoroscopy Table and the OAKWORKS Spine
Disconnect the power supply plug prior to cleaning any surfaces below or inside
of the base of the table.
3
PRODUCT DESCRIPTION - CFPMFXH
22” X 84” INTEGRATED HEADREST TOP
Carbon Fiber Top with
Hand Rail
Removable Table Top Pad
PRODUCT DESCRIPTION - CFPMFXH
PRODUCT DESCRIPTION
CAUTION
The CFPMFXH is a fixed height
table. It is recommended that
all patients are assisted onto
the table (physical assistance
& step stools with side rails is
recommended.)
• Included Accessories: Table Top Pad with 1” Medical
Grade Foam & TerraTouch™ Fabric
• Height: 37” (91 cm) (optional heights are available)
1- 2”H x 12” SQ Head Rest Pad
1 - 4”H x 12” SQ Head Rest Pad
1 - Crescent Face Pad
• Optional
Accessories: Carbon fiber arm board, Spine
Positioning System, Fluoro-Extender,
2” Table top pad
4
PRODUCT DESCRIPTION - CFPMFXH
24” X 80” RECTANGULAR TOP
Carbon Fiber Top with
Removable Table Top Pad
Locking
Casters
(2 sets)
PRODUCT DESCRIPTION - CFPMFXH
Hand Rail
PRODUCT DESCRIPTION
CAUTION
The CFPMFXH is a fixed height
table. It is recommended that
all patients are assisted onto
the table (physical assistance
& step stools with side rails is
recommended.)