OAKWORKS GMCTMP Instruction Manual

INSTRUCTION MANUAL
OAKWORKS
®
INSTRUCTION MANUAL
Manual Part # MMMNCG0109 Edition 3, English May 2007 Printed in U.S.A.
MASSAGE TABLES
64CA
© 2005 OAKWORKS®, Inc.
Manual Part # MMMNCG0109 Edition 3, English May 2007
All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of O
AKWORKS
®
, Inc.
O
AKWORKS
®
is a registered
trademark of OAKWORKS®, Inc.
Notice
The information contained in this document is subject to change without notice and should not be construed as a commitment by OAKWORKS®, Inc.
O
AKWORKS
®
, Inc. assumes no responsibility for any errors that may appear in this document nor does it make expressed or implied warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
O
AKWORKS
®
, Inc. shall not be liable for incidental or consequential damages in connection with or arising out of the furnishing, performance, or use of this document and the program material which it describes.
CONTACT INFORMATION:
OAKWORKS®Inc.
923 East Wellspring Road New Freedom, PA 17349
Toll Free (USA only): 800-916-4613 Phone: 717-235-6807
Toll Free FAX (USA only): 877-562-4787 FAX: 717-235-6798
www.oakworks.com
WARRANTY STATEMENT
All warranties are limited to factory-provided replacement parts, factory repair or replacement, at the discretion of OAKWORKS®.
All warranties exclude damage caused by improper set-up, accident, abuse, misuse, neglect, use for other than intended purpose or reasonable wear such as tears in the upholstery.
All warranties are invalidated by non-factory modifications and unauthorized repairs, which will immediately terminate all liability by O
AKWORKS
®
for the product or damages caused by its use.
The buyer and its customers shall be responsible for proper set-up and use of the products as well as any supervision required for safety. In no event shall O
AKWORKS
®
be liable for any special, indirect, consequential, incidental, exemplary or punitive damages or costs. Use of non-approved cleaning solutions voids the guarantee on all fabrics.
The warranties set forth herein are the sole and exclusive warranties provided by O
AKWORKS
®
. There are no other warranties, representations or guarantees provided by OAKWORKS®either expressed or implied, including warranties of merchantability and fitness for a particular purpose.
Warranty valid with proof of purchase.
26
Model No. GMCTMP
Celesta Gemini
TABLE OF CONTENTS
i
TABLE OF CONTENTS
Symbol Identification .......................................................................... pg iii
Warnings .............................................................................................. pg iv
Grounding Instructions ......................................................................... pg vi
Introduction .......................................................................................... pg 1
Section I: Product Description & Photo
Celesta Gemini
....................................................................... pg 2
Section II: Installation
Leveling Instructions ....................................................... pg 4
Section III: Directions for Use
Celesta Gemini
......................................................................... pg 5
Under-Table Cabinet .......................................................... pg 9
Side Arm Rests ................................................................. pg 11
QuickLock™Face Rest
........................................................ pg 13
Accessory Option: Table Extender ................................ pg 15
Moving the Celesta Gemini
.............................................. pg 15
Section IV: Troubleshooting
If Table Will Not Change Height or Angle
................... pg 16
Hand Control Replacement Instructions ..................... pg 16
Foot Control Replacement Instructions ....................... pg 19
Section V: Care & Cleaning ................................................................. pg 22
Section VI: Product Identification ...................................................... pg 23
Section VII: Table Specifications......................................................... pg 24
Section VIII: List of Parts ................................................................... pg 25
Section IX: Warranty .................................................................... pg 26
Contact Information ........................................................................... IBC
TABLE OF CONTENTS
WARRANTY STATEMENT
• How to Care for Your Upholstery
WARRANTY STATEMENT
FRAME/UPHOLSTERY ELECTRICAL RETURN REPLACEMENT
UNDERSTRUCTURE /PADDING COMPONENTS SHIPPING SHIPPING
Limited Lifetime
Warranty —
original owner;
International :
10 years
5 years 2 years not
Included
Included in Continental US; not included on
International
ii
SYMBOL IDENTIFICATION
• How to Care for Your Upholstery
SYMBOL IDENTIFICATION
FLUOROSCOPY TABLE
Part No. Description
2378 Column DL1(4)
2379 Cable, Motor (1)
7324-1 Control Box, Master (1) 7324-2 Control Box, Master / EU (1) 7324-3 Control Box, Master / Japan (1)
7328-1 Control Box, Slave (1) 7328-2 Control Box, Slave / EU (1) 7328-3 Control Box, Slave / Japan (1)
2401 Power Cord, Control Box
2403 Hand Control/10 Button (1)
2404 Foot Control (1)
7736 Receptacle/15A Beige (1)
7791 Power Cord,Main /North America (1) 7791-02 Power Cord / United Kingdom (1) 7791-03 Power Cord / Europe/Italy (1) 7791-04 Power Cord / Swiss (1) 5589 Power Cord / Japan (1) 7791-06 Power Cord / Australia (1)
Celesta Gemini
LIST OF PARTS
MODEL GMCTMP
25
LIST OF PARTS
LIST OF PARTS
Part No. Description
0301 Table Extender
QuickLock™Face Rest (2 parts) 0218 - Platform (1) 2410-03 - Crescent Face Rest Pad(1)
7811-03 Side Arm Rest Cushion/ Right (1) 7812-03 Side Arm Rest Cushion / Left (1)
7813-03 Side Arm Rest /Right; assembly includes frame
& cushion (1)
7814-03 Side Arm Rest / Left; assembly includes frame
& cushion (1)
46467 Manicure Armrests (2)
3680-1,2,3,4 Hot Towel Caddy
Accessory Options
SPECIFICATIONS
Model No. GMCTMP
Designed For: North America Europe/Switzerland United Kingdom Australia Japan/Korea
Voltage/Current Service Available
Input Frequency
Voltage Output
Current Consumption w/o internal Outlets
Electric Shock Protection
Mode of Operation
Storage & Transport
* measurements are determined from floor to top of seat pad using standard padding;
these measurements can be affected by natural material variations in padding.
120 VAC/ 20 amps
60 Hz
Temperature: 14Þ F - 140Þ F Humidity: 60% relative humidity Pressure: no limitations known
-10Þ C - 60Þ C During transport, DO NOT stack containers.
24 VDC
4.7 amps
Class I Equipment
Continuous Operation is
limited to a 10% Duty
Cycle (2 min. - 18 min.
rest)
220 VAC/ 10 amps
50 Hz
24 VDC
2.6 amps
Class I Equipment
Continuous Operation is
limited to a 10% Duty
Cycle (2 min. - 18 min.
rest)
220 VAC/ 10 amps
50 Hz
24 VDC
2.6 amps
Class I Equipment
Continuous Operation is
limited to a 10% Duty
Cycle (2 min. - 18 min.
rest)
220 VAC/ 10 amps
50 Hz
24 VDC
2.6 amps
Class I Equipment
Continuous Operation is
limited to a 10% Duty Cycle
(2 min. - 18 min. rest)
100 VAC/ 20 amps
50/60 Hz
24 VDC
5.6 amps
Class I Equipment
Continuous Operation is
limited to a 10% Duty
Cycle (2 min. - 18 min. rest)
Length:
Width:
Height Range*
Weight*
Shipping Weight
Shipping Crate Dimensions
Maximum Working Load Rating
Total Outside Dimensions:
Storage Area 1/ Head End:
Storage Area 2/ Foot End:
Opening Dimensions: Storage Area 1/ Head End:
Opening Dimensions: Storage Area 2/ Foot End:
14.875"
H x 24.25" W
x 56.5"L
13.5"
H x 24.25" W x
21.75"
L
13.5"H x 24.25"W x 17"L
13.5"HX20.125" L
13.5"H x15.375"L
Cabinet Dimensions:
182 cm
74 cm
61 cm - 81 cm
~ 137 kg
~ 159 kg
205.7cm x 91.4cm x 89cm
283 kg
72"
31"
25" - 37"
~ 301 lbs.
~ 350 lbs.
81"
L x 36" H x 35" W
625 lbs.
182 cm
74 cm
61 cm - 81 cm
~ 137 kg
~ 159 kg
205.7cm x 91.4cm x 89cm
283 kg
182 cm
74 cm
61 cm - 81 cm
~ 137 kg
~ 159 kg
205.7cm x 91.4cm x 89cm
283 kg
182 cm
74 cm
61 cm - 81 cm
~ 137 kg
~ 159 kg
205.7cm x 91.4cm x 89cm
283 kg
24
SPECIFICATIONS
SPECIFICATIONS
Celesta Gemini
E L E C T R I C A L
S P E C S
T A B L E
S P E C S
37.8cm L x 61.6cm H x
143.5cm W
34.3cm L x 61.6cm H x
55.2cm W
34.3cm
L x 61.6cm H x
43.2cm
W
34.3cm H x 51.1cm L
34.3cm H x 39.1cm L
37.8cm L x 61.6cm H x
143.5cm W
34.3cm L x 61.6cm H x
55.2cm
W
34.3cm L
x 61.6cm H x
43.2cm
W
34.3cm H x 51.1cm L
34.3cm H x 39.1cm L
37.8cm L x 61.6cm H x
143.5cm W
34.3cm L x 61.6cm H x
55.2cm W
34.3cm L x 61.6cm H x
43.2cm
W
34.3cm
H x 51.1cm L
34.3cm H x 39.1cm L
37.8cm L x 61.6cm H x
143.5cm
W
34.3cm L x 61.6cm H x
55.2cm W
34.3cm L x 61.6cm H x
43.2cm W
34.3cm H x 51.1cm L
34.3cm H x 39.1cm L
SYMBOL IDENTIFICATION
iii
SYMBOL IDENTIFICATION
SYMBOL IDENTIFICATION
SYMBOL IDENTIFICATION
This symbol, when used in documentation on this product, represents a caution. Be sure to read and comply with all precautions and warnings.
This symbol, when used in documentation on this product, indicates danger and warns against an electrical shock hazard. Be sure to observe and comply with all warnings and instructions.
This symbol, when used in documentation on this product, indicates a Protective Earth (Ground) Terminal.
This symbol when used in documentation on this product, warns that dur­ing transport there should be no stacking of containers.
This symbol, when used in documentation on this product, indicates that the product should be protected from moisture. The humidity specifications for Transport & Storage are listed on page 24.
This symbol, when used in documentation on this product indicates that information is given regarding the recommended temperature limits during transport and storing. The specifications for these limits are listed on page 24.
This symbol, when used in documentation on this product, indicates the date of manufacture of the device.
This symbol, when used in documentation on this product indicates alternating current (AC).
This symbol, when used in documentation on this product, indicates direct current (DC).
This symbol, when used in documentation on this product, indicates that instructional information is included. All instructions should be read carefully and completely before using the equipment.
~
----
Improper use of this device can cause injury. Be sure to read all operating instructions prior to use to prevent injury to operator or client.
Electrical Shock Hazard. To reduce the risk of electric shock, always disconnect the table from the electrical outlet before moving the table or doing any maintenance or troubleshooting procedures. Never use this equipment if it has a damaged cord or plug. Use this equipment only for its intended use as described in these instructions. Do not use any attachment or accessories not recommended by the manufacturer.
To reduce the risk of burns, fire, electrical shock or injury:
• The power supply/control module is located at the head end of the table beneath the base. Refer servicing to qualified personnel and follow manual instructions when doing any authorized troubleshooting. Before doing any work on the unit, disconnect the power cord from the power outlet.
• Before cleaning with any liquid cleaner be sure to un-plug the power cord from the power outlet. Do not operate the table in standing water.
• Be careful of slack in the power cords as you put the control box back in the cabinet when troubleshooting to avoid pinching cords between the cabinet base and the control box bracket.
• Before moving the table, disconnect the power cord from the power outlet and secure the electrical cord, hand control and foot controls out of the way for moving.
Risk of Electrical Shock. — Connect this table to a properly grounded outlet only. See Grounding Instructions.
• Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
• Never operate this table if it has a damaged cord or plug., if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
• Keep the cord away from heated surfaces.
• Do not use outdoors.
• Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
Risk of Injury — Keep children from moving headrest and foot support.
Never drop or insert any object into any opening.
POWER LEAD PLUGS
OAKWORKS®Part #: Voltage (ACE) Power Cord Plug
7791 120v 60 Hz 3 prong grounded
hospital grade; North America
7791-03 220v 50 Hz Continental Plug;
Europe/Italy
7791-04 220v 50 Hz Swiss plug; Switzerland
7791-02 220v 50 Hz British plug;
United Kingdom
7791-05 100v 50/60 Hz 3 prong polarized plug;
Japan & Korea
7791-06 220v 50 Hz Australian Plug; Australia
23
PRODUCT IDENTIFICATION
• Power Lead Plugs
PRODUCT IDENTIFICATION
PRODUCT IDENTIFICATION
• Plugs
These part numbers are for identification only; they are not field serviceable items.
iv
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
• How to Care for Your Upholstery
WARNINGS
WARNINGS & IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
DANGER
READ AND SAVE THESE INSTRUCTIONS
WARNING
WARNING WARNING
Loading...
+ 12 hidden pages