Oakworks Clodagh Libra User Manual

USER MANUAL
Libra
www.oakworks.com · 717.235.6807
© Copyright 2010 OAKWORKS® , Inc.
All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of OAKWORKS®, Inc.
OAKWORKS® is a registered trademark of OAKWORKS®, Inc.
Notice
The information contained in this document is subject to change without notice and should not be construed as a commitment by OAKWORKS®, Inc.
OAKWORKS®, Inc. assumes no responsibility for any errors that may appear in this document nor does it make expressed or implied warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
OAKWORKS®, Inc. shall not be liable for incidental or consequen­tial damages in connection with or arising out of the furnishing, per­formance, or use of this document and the program material which it describes.
TABLE OF CONTENTS
Product Use Description ...................................................................................................... 1
Important Safety Instructions
Symbol Identification .................................................................................................... 1
Safety Instructions ......................................................................................................1-2
Product Description & Photo
Clodagh Libra ................................................................................................................3
Installation
Facility Plumbing Instructions ..................................................................................4-5
Facility Electrical Instructions ...................................................................................... 6
Grounding ..................................................................................................................... 6
Directions for Use
Control Operations ........................................................................................................ 7
Moving the Table ...........................................................................................................8
Leveling the Table .........................................................................................................8
Storage Shelf Use ........................................................................................................... 9
Accessory Outlet ............................................................................................................ 9
Lowered Arm Rest Use ................................................................................................. 9
Adjustable Arm Rest Installation and Adjustment .................................................. 10
Leg Rest Use.................................................................................................................11
Foot Rest Use ...............................................................................................................11
QuickLock Face Rest ...................................................................................................12
Manicure Arm Rest Use .............................................................................................. 12
Foot Bath Use .......................................................................................................... 13-14
Cleaning & Disinfection ................................................................................................... 15
Inspections & Maintenance ............................................................................................. 15
Warranty Information ......................................................................................................... 15
Model Number & Serial Number ..................................................................................... 16
Specifications
Product Specifications .................................................................................................17
Environmental Conditions .........................................................................................17
Electrical Specifications ..............................................................................................17
Contact Information ............................................................................................back cover
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS
PRODUCT USE DESCRIPTION
The Clodagh Libra is a powered positioning table used to support the client during spa treatment, massage, pedicure and manicure procedures. It is intended to be operated by a healthcare profes­sional in a spa environment. No special training is required but a review of the following Safety Instructions is important for the safety of the operator and client. The healthcare professional should read and understand this entire manual before use with a client. There are no known contradictions to the use of this equipment.
SYMBOL IDENTIFICATION
This symbol, when used in this manual and on product labels, represents a caution warning. Be sure to read and comply with all precautions and warnings.
This symbol, when used in this manual and on product labels, warns against an electrical shock hazard. Be sure to observe and comply with all warnings.
This symbol, when used in this manual or on product labels, indicates a Protective Earth (Ground) Terminal.
This symbol, when used in this manual or on product labels, indicates that the product should be protected from moisture. The humidity specifications for Transport & Storage are listed in the environmental conditions section of this manual.
This symbol is used in documentation on this product, warns that during transport there should be no stacking of containers.
This symbol is used to indicate that the operator should consult the user manual.
This symbol, when used in this manual or on product labels, indicates alternating
~
----
current (AC).
This symbol, when used in this manual or on product labels, indicates direct current (DC).
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
The Backrest and Leg Rest sections are not designed to support the entire weight of the patient. Do not sit on the Backrest or Leg rest sections.
Consult your physician if you are diabetic, have poor circulation, if any area of your feet or legs are inflamed, has an open wound or if any other questions about whether you should be using hydro massage equipment.
As with any moving mechanism there are potential pinch points around and underneath the table. It is the responsibility of the operator of this equipment to insure that bystanders are not in the area below or around this equipment during opera­tion.
READ AND SAVE THESE INSTRUCTIONS
1
IMPORTANT SAFETY INSTRUCTIONS
Maximum Table Weight Limit: (patient and accessories) 500 lbs./226 kg. Do not exceed.
Maximum Shelf Weight Limit: 225 lbs./102 kg. Do not exceed.
Maximum Leg Rest Weight Limit: 125 lbs./57 kg. Do not exceed.
Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
Close supervision is necessary when this furnishing is used near children or disabled persons.
The table weighs as much as 342 lbs./155 kg. Never lift the table by the table top. Do not turn the table on its side.
When making adjustments to the arm rests, make certain that the client’s arms are away from the working mechanism.
Do not extend the accessory dowels more than 3” (8 cm.) from the table edge.
Do not store or place anything on the cabinet hood or under the backrest. This can cause damage to the table.
Foot Bath:
a. Risk of accidental injury or drowning. Exercise care when entering or exiting of the foot bath. Invalid or disabled persons should not use the hydro foot bath without trained supervision.
b. Risk of scalding and possible drowning: Water temperatures in excess of 104º F (38º C) may be injurious to your health. Check and adjust water temperature before use.
c. Should you experience any pain or discomfort while using the foot bath, discontinue use immediately and consult your physi­cian.
d. Unless thoroughly cleaned after each use, bath residue will buildup within the jets and on the surface area of any whirlpool foot bath, which can promote the growth of bacteria.
e. DO NOT operate water jets unless completely installed or without water filled to the water level indicator above the jets. f. DO NOT overfill the foot bath. g. DO NOT stand on or in the foot bath. Use only while seated.
WARNING
To reduce the risk of burns, fire, electric shock or injury to persons:
1. Unplug this furnishing from the electrical outlet before cleaning.
2. Unplug from outlet before adding or removing parts.
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8. This product is equipped with an interior accessory outlet (110V only). The total electrical load plugged into this set of outlets is not to exceed 1000 watts.
9. DO NOT permit electric appliances (e.g. hair dryer, lamp, telephone, radio, television, etc.) to be within 5 feet (1.5m) of this
appliance.
10. DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
DANGER
If a floor outlet is used, the outlet must not be recessed in the floor (to prevent water entering the outlet in the event of an overflow).
Risk of electric shock - Connect this furnishing to a Ground Fault Protected Outlet only. See Grounding Instructions in this manual.
Electrical Shock Hazard. The power supply/control module is located under the chair. No user serviceable parts are inside the control box. Refer servicing to qualified personnel. Unplug wall plug prior to contact with any cables connected to the power supply.
2
PRODUCT DESCRIPTION
Clodagh Libra
Manicure Arm Rests (2) (optional)
Hydraulic Lift
Columns (4)
Electronic Backrest
Electronic Seat
Pedi Foot Bath
Storage Shelf
Manual Leg
Rests (2)
Removable Foot Rest
STANDARD SPECIFICATIONS
Motion 1 Powered 25” - 33” (64-84cm.) Height Range Patient Capacity 500 lbs. (227 kg.) (patient and accessories)
Motion 2 Powered 0-4” (0-10 cm.) Seat Width 30” (76 cm.)
Motion 3 Powered 75º Backrest Length 77” (195 cm.)
Motion 4 Manual Leg Rests Padding 4” (10 cm.) Areocell
Foot Control All powered motions Upholstery Premium, PVC free TerraTouch
Table Voltage Options 120V/60Hz or 230V/50Hz Table Weight 342 lbs. (155 kg.)
Storage Shelf
24” x 37” (61 x 94 cm.) (usable opening 11.75” x 32” (30 x 81 cm.))
Wood Stain Natural Maple Finish
Warranty 3 year parts, 1 year labor
OPTIONS / ACCESSORIES
Wood Finishes Lowered Arm Rest
Adjustable Side Arm Rests (2) Manicure Arm Rests (2)
QuickLock Face Pad Hand Control - All powered motions
For electrical specs, see Specifications section.
3
INSTALLATION
The table comes completely assembled and ready to use. Plug the cord into a functioning GFCI outlet that is rated for the table.
Arrange the power cord and foot switch so that they will not create a tripping hazard. Place the controls in a safe location where they are convenient and accessible. Keep the controls out of the way of all table mecha­nisms.
If your table was ordered with the optional faucet & drain, please review typical installation instructions in the section below.
FACILITY PLUMBING INSTRUCTIONS
When installed in the United States, the plumbing of this table must meet the requirements of
CAUTION
Customer Supplied Parts list:
1. (2) 20” long flexible braided water supply lines with 3/8” male end foot bath faucet connection
2. (2) Shut off valves for Facility Hot/Cold water supply connection
3. (2) 1.5” PVC adapters
4. (1) 1.5” Flexible drain line for Facility DWV system connection.
Facility Connection Requirements:
1. An existing below floor plumbing trap and flexible drain line connection to the Libra table located on floor as detailed by illustration shown in these instructions.
2. Hot and cold water supply with braided flexible supply lines that will interface to a 3/8” female compression fit­ting. (supplied on the Libra table)
any applicable state or local codes. Plumbing rough in and final hook up should be performed by a qualified plumber and approved by a local building/plumbing inspector.
Procedure:
a. The print below shows the details of where the plumbing rough-in locations under table are required to be posi­tioned for proper installation.
b. Customer to provide flexible 3/8” braided water supply lines of at least 20” in length for interfacing to facilities hot and cold water supply located on the floor beneath the table as shown in the above picture.
4
INSTALLATION
c. The table comes equipped with a faucet that has flexible 3/8” compression lines with female ends. The customer supplied flexible line will need to have male 3/8” compression to be connected to the faucet supply line.
Table - Female 3/8” compressions
d. The table comes equipped with a 1.5” PVC fitting at the drain location for the installer to connect to.
Male/Female fitting connection
Customer supplied Flexible line with Male 3/8” com­pression fitting
e. The Flexible 1.5” drain line supplied by customer and interfaced between the table drain and the facility drain in the floor.
5
Loading...
+ 16 hidden pages