Congratulations on your purchase!
You have purchased a state-of-the-art SEVEN STAGE air purification system with high quality filters.
Breath easy knowing that your purifier will greatly increase the air quality of your home or office. We
hope that you will enjoy your O3PURE AIR Purifier for years to come.
IMPORTANT:
PURIFIER MUST BE BROUGHT TO ROOM TEMPERATURE PRIOR TO USAGE. FAILURE TO DO SO WILL
DAMAGE THE INTERNAL WORKINGS OF THE UNIT. This damage will not be covered under warranty.
NEVER OPERATE YOUR PURIFIER WITH A BROKEN PLATE. DOING SO WILL CAUSE DAMAGE TO THE UNIT.
This damage is not covered under warranty.
Precautions:
This unit employs a ground type (3 prong) plug which will only fit into a grounding type power outlet. Do
not use an adapter. Do not attempt to bypass this feature by altering the plug in any fashion.
Do not use outdoors or on wet surfaces.
Do not use with damaged cord or plug
Do not unplug by pulling on the cord. Grasp the plug, not the cord.
Do not operate this unit in areas where flammable or combustible products or vapors may be present.
Always turn “off” and unplug the unit prior to performing maintenance.
Read all instructions carefully before using this product.
INSPECTION AND INSTALLATION
Remove the unit from shipping carton and SAVE all protective packing materials.
Remove the White Ceramic Purification plate from its package. The ceramic plate is not installed in the air purifier by the
factory to prevent breakage during shipment. Verify that the White Ceramic Purification plate is intact and unbroken
Remove filters (4) from rear of unit:
.
Rear Diagram
1 Dirt, Dust & Debris Pre-Filter
4. Check to make sure that the UV cartridges (bulbs) are not broken.
5. Now that all of the filters are removed,
Oxygen plate] into the purifier.
a) Make s
b) Grasp the end of the ceramic plate and (following the photographs below) and slide the plate vertically into card
.
lot
s
1. The pre-f
2. The w
3. The blac
4. The Ph
2 Hospital-Grade HEPA Filter
ure the plate is installed with the arrows pointing towards the inside of the unit.
Activated Oxygen
3
Plate
O
ilter is removed by unscrewing the 4 thumb-screws on the back of the purifier.
hite HEPA filter is removed by pulling on the attached ribbon-tab at the top of the filter.
k Activated Carbon filter is removed by pulling on the attached ribbon-tab at the top.
oto-Catalytic Filter is removed by pulling on the attached ribbon-tab at the top.
3 Activated Carbon Filter
install the white Ceramic Purification plate [also referred to as O3 Activated
4 Photo-Catalytic Filter
(2) Germicidal UV bulbs
6. Reinstall the 3 inner filters in the following order:
FIRST, with the ribbon to the outside, place the Photo-Catalytic Filter in the unit so that the safety tab can no longer
be seen. CAUTION: When properly installed, the Photo-Catalytic Filter will push the safety tab towards the center
of the unit and will no longer be visible
***THE PURIFIER WILL NOT TURN-ON IF THIS FILTER IS NOT INSTALLED PROPERLY.
TAB LOCATION
. See photos BELOW for proper installation.
CORRECT INSTALLINCORRECT INSTALL
SECOND, insert the black Activated Carbon filter. Make sure the ribbon-tab is on the outside
THIRD, insert the HEPA filter in next. Make sure the ribbon-tab is on the outside.
LA S T LY, replace the Pre-Filter and install the 4 thumb screws to secure.
7. Determine a lo
proper air flow. Elevated placement is preferred as activated oxygen (03) is heavier than air. Increasing the elevation
increases the performance of the purifier.
cation for your unit(s). Allow a minimum of six inches between the back of the unit and the wall to allow
8. Plug unit into an appropriate (three prong grounded) outlet. Be sure the power switch on the rear of unit is in the “ON”
p
osition.
GENERAL MAINTENANCE
Periodic maintenance of your air purifier is important. A good
rule of thumb is to give your unit a “once-over” every 30 to 40
days to ensure continued optimal performance.
IMPORTANT: Disconnect power cord from both unit and wall
prior to performing any maintenance function
Cleaning the Pre-Filter, HEPA Filter, Carbon and
Photo-Catalytic Filter
If Dirt is visible, take out the filters and remove particulate by:
WIPING the carbon and photo-catalytic filters with a clean
cloth or vacuum with brush attachment.
RINSING the Pre-filter and HEPA filters using hot water every 3
to 6 months, depending on usage, and allow to air dry.
Filters MUST BE thoroughly dry before re-installing.
Filters are removed
in this order
WASHABLE
Dirt, Dust &
Debris Pre-Filter
WARNINGS:
DO NOT USE soap or detergent as it will damage the
material in the filters.
DO NOT USE a hairdryer to accelerate the drying time!
Cleaning the activated Oxygen O3Plate
Remove the Pre-Filter, the
HEPA filter, the Activated
Carbon and Photo-Catalytic
filters. Carefully remove the
white purification plate by
grasping the end and carefully
pulling straight out of the
card slot. Clean the plate
with a stiff brush using a 50/50 solution of ammonia and
hot water. Rinse plate in warm water and dry thoroughly
before re-installing. The plate MUST BE thoroughly dry before
re-installing.
WASHABLE
Hospital-Grade
HEPA Filter
3
CLEANABLE
Activated
Carbon Filter
4
CLEANABLE
Photo-Catalytic
Filter
Cleaning the Front Grill and Fan Blades
Note:It is normal for the
ANIONtocausesome
particles to accumulate on
the front grill and fan blades.
Use a Phillips-head screw
driver to remove the (4)
screws inthe front grill
cover.Simply clean the
blades and grill with a damp
cloth or vacuum.Allow to
dry completely before reattachingthefrontgrill
cover.
Activated Oxygen
(PURIFY) O
3
Plate
USING THE PURIFY FUNCTION
The purify setting is a powerful part of your purifier. It engages the ozone (O3) generator in the unit. This is a
great solution for mold and strong odors. The PURIFY (O3) is not designed to be left on all the time, but
rather to be used for short periods or with the timer, to cleanse unoccupied areas. When used for mold
eradication in musty moldy basements, set the timer on the unit so that it runs for 2 or 3 hours on highest fan
and purify settings, then leave the area or shut the area off by closing the door. Set the unit to shut down at
least 30 minutes prior to your return. These 30 minutes allow ozone (O3) to turn into oxygen (O2) rich air.
See instructions below when used to overcome odors. As a good rule of thumb, when you no longer smell
the odor and instead smell the ozone (O3), the ozone has done its job and you may turn the ozone off and
return the unit to normal settings.
Press “Purify ” or “Purify ” to adjust the level of activated oxygen (O3). There are five stages. Use the
following chart to determine the proper setting for the area to be purified. Reference the chart below for
recommended purify levels. These levels are considered safe for short periods of time when the room is
occupied. HOWEVER, INDIVIDUALS WITH ASTHMA OR ANY RESPIRATORY OR LUNG CONDITION SHOULD NOT
BE IN THE ROOM WHEN THE PURIFY FEATURE IS ENGAGED.
Yes, but moderation is the key. Use your nose – if you can smell ozone, it is time to turn it off.
The following guidelines should be strictly adhered to:
Set the Purify (O3) Level properly for the room size.
Run the Purify (O3) feature for short periods of time. Do not continuously run the Purify feature.
Individuals with asthma or any respiratory or lung condition should not be in the room when using
the
Purify feature.
Only set the Purify Level on higher settings when the room is unoccupied (people and animals) to
Use the (O3) Timer to run the ozone safely on higher settings in unoccupied setting and allow the
unit to shut down this PURIFY feature automatically.
When someone in the room is using bottled Oxygen, you should not use the purify (03) feature.
Ozone in very high concentrations can be irritating to mucous membranes and the respiratory
system. Relatively low levels of ozone may cause chest pain and shortness of breath. Ozone may worsen
asthma and compromise the ability of the body to fight respiratory infections.
Please refer to User’s Guide for additional instructions on the Purify Function, as well
Operating Settings, Setting the Clock, etc.