Cables and Requirments ....................................................................................... 22
PARTS AND FUNCTIONS
Part Names
Surface mounted
[13]
Flush mounted
[11]
[12]
[11]
[12]
[10]
[1]
[9]
[8]
[7]
[6]
[5]
[14]
[9]
[8]
[2]
[3]
[4]
[1]
[2]
[3]
[13]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[7]
[4]
[6]
[5]
[10] Rainy cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
[14] Mounting box
-3-
PARTS AND FUNCTIONS
Mounting
The installation height is suggested to 145~160cm.
Surface mounted
12345
The distance between
Main unit
the top of main unit
and rain cover should
be not less than 3mm.
Rainy cover
≥0.12 inch
Main unit
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
1. Connect the cable correctly.
2. Drill holes in the wall to match the size of screw stoppers,then attach the rainy cover and
main unit to the wall,and the distance between the top of main unit and rain cover should be not
less than 0.12 inch.
3. Install the name plate.
4. Attach the front panel to the main unit.
5. Use the special screwdriver and the screws to x the panel.
Flush mounted
12345
AcDbMLeader (ACDB_MLEADER_CLASS)
1. Drill a hole in the wall to match the size of mounting box,then attach the mounting box to the
wall.
2. Loosen the high screws to install the name plate.
3. Connect the cable correctly.
4. Attach the front panel to the mounting box,then use the special screwdriver and the screws to
x the panel.
5. Finish the installation.
* The camera angle view of surface mount model may be less than 1700.
-4-
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
PARTS AND FUNCTIONS
Terminal description
1 2 3
+12V
L2
L1
GND
PL
PIR
Lock Control Jumper
S-
S+
PIR Motion Detector
Connect Port
Main Connect Port
Lock Control Jumper:
Motion Detector Connect Port:
Main Connect Port:
L1,L2:
•
•
•
•
Connect to the bus line, no polarity.
PL:
External lock power input, connect to the power positive(power +).
S+:
Lock power(+) output.
S-:
Lock power(-) output, connect to the power(-) input of locks(only when using the door
To select the lock type.
To connect external PIR motion detector.
To connect the bus line and the electronic locks.
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
-5-
BASIC FUNCTIONS
detector
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator
will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
Please note that this function requires the
monitor with sheye function to support.
The angle view is 1700,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
with sheye function.
Standard
door station angle
DT607
1700 door camera angle
(Wide angle view shown)
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected
to the system,following functions will be effec-
tive:
If detect someone passing by, the door station
can be activated operation to unlock or turn
on light.
* Please contact with supplier for more details about
detector connection.
-6-
12V
GND
PIR
Motion
SETUP INSTRUCTIONS
Functions Setting Up
This section explains the settings of each
function,please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the
LED
indicator on the unit, and by
the sounding of the buzzer.
OrderSetting itemsSetting rangeDefault value
1Setting door station address0~30
2Setting camera resolutionHigh/LowHigh
LED_NAME
RF CARD
LED_UNLOCK
LED_TALK
KEY_SET
KEY_4
KEY_3
KEY_2
KEY_1
3Setting the unlock mode0:opened/1:closed0:opened
4Setting the unlock time01 to 99 seconds1 seconds
5
6
7Setting ring-back tone
8Setting image display mode
Setting the nameplate
illumination mode
Setting night view LED
illumination mode
On/Off/AutoOn
On/Off/AutoAuto
Ringing one time
Ring continuously
No ring-back tone
Alternate switching mode
Zoom mode
Full screen mode
Ringing one time
Alternate switching mode
-7-
SETUP INSTRUCTIONS
Setting Door Station Address
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
ID=0,1st door stationID=1,2nd door stationID=2,3rd door stationID=3,4th door station
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep+
Press KEY_2 button to set
the second door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Press KEY_3 button to set
the third door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
Buzzer
Beep+, Beep
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep,Beep
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
freely.
LED_NAME
• The
indicator will always blink until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press
KEY_SET
button four times to exit out the setting mode manually.
-8-
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.