Gas Range Manual for Installation,Care&Maintenance
AK3001 AK3605 AK4807
![](/html/69/699d/699dcc64c209d67930005936eed5ee9e4263b86ebe312fc3de495a73388fcc18/bg2.png)
INSTALLATION INSTRUCTIONS
IMPORTANT
Keep appliance area clear and free from combustible materials,gasoline,and other
flammable vapors.
Gas Supply Requirements
Installation of this range must conform with local codes,or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1 / NFPA 54. In Canada,installation must
conform to the current natural Gas Installation /code,CAN 1-1.1-M81 and with local
codes where applicable.This range has been design-certified according to ANSI Z21.1-
2016/CSA 21.1-2016 latest edition.
A statement of the maximum gas supply pressure in accordance with the inlet pressure
rating of the gas appliance pressure regulator supplied.
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR LP GAS---14.0 IN.W.C.
MINIMUM GAS SUPPLY PRESSURE TO APPLIANCE FOR NG --- 6 IN.W.C.
APPLIANCE REGULATOR IS SET AT 5.0 IN. W.C. OUTLET PRESSURE.
Do not obstruct the flow of combustion air into the range and ventilation air away from
the range.
Ventilation: it is recommended that the unit be operated with an oven head,vented
exhaust hood of sufficient size and capacity.
Before installing the range,you must locate and secure the included anti-tip bracket to the
wall for your range.
CAUTION
The use of cabinets for storage above the appliance may result in a potential
fire hazard.Combustible items may ignite;metallic items may become hot
and cause burns. If a cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects horizontally a minimum of
5" (12.7cm) beyond the bottom of the cabinets.
The appliance shall not be used for space heating.This information is based
on safety considerations.All openings in the wall behind the appliance and
in the floor under the appliance shall be sealed.
9
![](/html/69/699d/699dcc64c209d67930005936eed5ee9e4263b86ebe312fc3de495a73388fcc18/bg3.png)
INSTALLATION INSTRUCTIONS
Dimensions and Clearances
The range may be installed flush to the rear wall. You may install a noncombustible material on the rear wall above the range and up to the vent hood.
It is not necessary to install non-combustible materials behind the range below
the counter top height.
The minimum distance from the side of the range above the counter top to
combustible sidewalls must be at least 10 inches.
INSTALLATION INSTRUCTIONS
3
〃
27
30〃
4
Heig
39
ht
4
〃
5
depth
with door op
1
44
〃
4
en
〃
10