Introduction
The NX-IMH12 is a stereo (two channel), one input twelve output, resistor based, broad frequency response, impedance matching audio dis tribution panel. The NX-IMH12 provides a simple solution in complex speaker installations providing an easy way to connect from two to twelve pairs of stereo speakers to a single stereo receiver/amplifier. All outputs are labeled easing both connection and troubleshooting of a system.
Features and Benefits
• 12 - Zone, 200 watt, stereo, audio distribution panel
• Isolated left/right circuit grounds provide safe connection for amplifiers with floating grounds or bridged configurations
• Detachable screw-type connectors accept up to 12 AWG wire
• High quality heavy-duty painted steel cabinet with ventilated cover for improved heat dissipation
• 3⁄4˝ and 1⁄2˝ cable/conduit knockouts allow easy wire routing to all connectors
• Cabinet may be surface, side, or flush mounted
• Designed for use with Class 2 wiring
Fig. 1
Mounting & Wiring Instructions
1. Remove the ventilated cover plate using the four thumbscrews and set everything aside until the wiring is finished.
2. Determine where you want the NX-IMH12 mounted and secure it to the wall or studs using the various holes in the cabinet.
3. Follow the suggestions that came with your receiver or speakers for
determining the correct wire gauge needed to connect your NX-IMH12 distribution panel. If necessary, you may want to consult a manufac­turer’s wire chart to determine the minimum wire gauge needed to minimize loss for long runs, which may be necessary to connect to the NX-IMH12 in a basement location.
4. Make all wire runs from each speaker location and your receiver/
amplifier to your NX-IMH12 panel.
5. Remove the NX-IMH12 knockouts you need to get your wire into the
panel depending on the location of your panel and the wire entry. If you are using conduit, use the proper fittings and pull all wire into the box with enough extra wire to dress and terminate later. If you are not using conduit, then use the supplied plastic grommets in the panel openings you knock out to protect the wire from damage when it’s pulled through the panel holes.
6. Remove the connector blocks from the NX-IMH12 panel PC boards
and make all the connections to the connector blocks as shown in Fig. 1. (If your receiver or amplifier has both A & B outputs connect your NX-IMH12 to your receiver’s “A” outputs.) Pay close attention to make certain all strands of bare wire are completely inserted into the connector properly and that no loose strands are outside the con­nector hole. Any loose strands could possibly touch another wire and short the receiver’s output. After you have tightened the screw terminals to secure the wires, insert the connector block back into NX-IMH12 as shown in Fig 2.
, you can put
7. Once you have verified ever
the cover plate back on the NX-IMH12 cabinet.
ything is working pr
operly
To Speaker
Circuits
Input from
Receiver/Amp
To Speaker
Circuits
If not using
conduit, use
plastic gr
in open hole
to prevent
wire damage
Backwall
Mounting
Holes
Fig. 2
ommet
Typical Speakers
Typical Room
Volume Controls
NXG One-Year Limited Warranty
f the NXG product proves to be defective in
I
orkmanship or materials within one year
w from the date of the original customer’s pur­chase, we will, at our option, repair or replace the defective product.
Limitation of Implied Warranties
ny implied warranties, including warranties
A of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty.
Receiver/Amplifier
NX-IMH12
Fig. 3 Typical System Diagram for the NX-IMH12 Audio Distribution Panel
NX-IMH12 Specifications
Power Handling: 120 watts RMS per channel
(suitable for use with 200 watt per channel rated receivers/amplifiers)
Frequency Response: 20 Hz - 22kHz (+0dB, -0dB)
e size acceptance:
W
ir
2 or 4 conductor
, stranded, 16 A
Dimensions: 121/4˝ (311mm) H x 99/16˝ (243mm) W x 3˝ (76mm) D
Maximum Number of Speaker Connections: 12 pairs @ 4 minimum
Maximum Amplifier Impedance with All Zones Connected:
4.7 with 8 speakers connected
4.3 with 4 speakers connected
Designed for use with Class 2 wiring only
WG to 12 AWG
Exclusion of Certain Damages
XG’s liability for any defective product is
N limited to repair or replacement of the product at our option. NXG shall not be liable for inci­dental or consequential damages of any kind or character because of product defects. Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limi­tations and exclusions may not apply.
This Warranty Does Not Cover:
• Damage caused by abuse, accident, misuse, negligence, or improper operation.
• Any product whose serial number has been altered, defaced, or removed.
• Products that have been altered or modified.
• Normal wear and maintenance.
• Damages caused by shipping. (All claims for shipping damage must be made with the carrier.)
Warranty Service
Warranty service must be performed by an authorized service center, usually a NXG dealer or its authorized agent. You may obtain a list of authorized service centers by contacting NXG. All warranty repairs must be accompanied by the original bill of sales. No other document is acceptable or is required. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
NXG reserves the right to revise specifications without notice.
16648 Nor
Scottsdale, AZ 85260
th 94th Street
1-800-733-0008
www.nxgtech.com
Loading...