nvent 24579-417, 24579-422, 24579-418, 24579-421, 24579-423 User Manual

...
3+1 U CPCI Serial System
User‘s Manual
Product Number:
24579-416/417/418/419/420/421/422/423/424
Doc-No: 63972-349_R1.0
January 2016
Schroff GmbH
Langenalber Str. 96 - 100 75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and checked - supported by certified Quality Management System to EN ISO 9001/2000
The company cannot accept any liabi
lity for errors or misprints. The company reserves the right to amendments of technical specifications due to further development and improvement of products.
Copyright
2018
All rights and technical modifications reserved.
R1.0 January 2016 Initial Release
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 I
1 Safety ....................................................................................................................... 1
1.1 Safety Symbols used in this document.............................................................................. 1
1.2 General Safety Precautions ............................................................................................... 1
1.3 References and Architecture Specifications.....
................................................................. 2
1.4 Product Definition .......................................................................................................... ...
2
1.5 System Overview............................................................................................................... 3
1.6
Subrack..............................................................................................................................
4
1.7 Backplane ..........................................................................................................................
5
1.8 Topology of a 9 Slot Backplane ......................................................................................... 6
1.9 Power Backplane............................................................................................................... 7
1.10
Power Supply.....................................................................................................................
8
1.10.1 CPCI Plug-In AC Power Supply............................................................................ 9
1.10.2 Grounding/Earthing ........................................................................................... 9
2 Cooling ................................................................................................................... 10
2.1 Air Filter........................................................................................................................... 11
2.2 Airflow..................................................................................................................... ........
11
3 Installation ............................................................................................................. 12
3.1 General Installation Guidelines ....................................................................................... 12
3.1.1 Unpacking ........................................................................................................ 12
3.1.2 Ensuring Proper Airflow................................................................................... 12
3.2 Rack-Mounting ................................................................................................................ 13
3.3
Initial Operation .............................................................................................................. 13
4 Service.................................................................................................................... 14
4.1 Technical support and Return for Service Assistance ..................................................... 14
4.2 Declaration of Conformity............................................................................................... 14
4.3 Scope of Delivery (24579-421)........................................................................................ 15
4.4
Accessories...................................................................................................................... 15
4.5
Spare Parts ...................................................................................................................... 15
5 Technical Data ........................................................................................................ 16
6 Dimensions............................................................................................................. 17
24579-4xx (CPCI Serial Systems 3+1 U)
II R1.0, January 2016
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Safe
ty 1
1 Safety
The intended audience of this User’s Manual is system integrators and hardware/software engineers.
1.1 Safety Symbols used in this document
1.2 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and connection practices for installing this equipment.
• Install this equipment only in compliance with local and national electrical codes.
Hazardous voltage!
This is the electrical hazard symbol. It indicates that there are dangerous voltages inside the Shelf.
Caution!
This is the user caution symbol. It indicates a condition where damage of the equipment or injury of the service personnel could occur. To reduce the risk of damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
Static electricity can damage sensitive components in a system. To avoid damage, wear ESD wrist straps or at regular intervals touch blank enclosure parts.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is intended to be
accessed, to be installed and maintained by qualified and trained service personnel only.
This equipment is designed in accordance
with protection class 1!
It must therefore be operated only with protective GND/earth connection!.
24579-4xx (CPCI Serial Systems 3+1 U)
2 Safety R1.0, January 2016
1.3 References and Architecture Specifications
• User Guide Schroff CPCI Serial Backplanes Order no.: 63972-333
• User Manual Power Backplanes Order no.: 63972-334
• User Manual 19“ Power Supply 11098-538 Order no.: 63972-335
1.4 Product Definition
The Schroff CPCI Serial system subracks are available in various backplane and PSU configurations and consist of:
• A shielded subrack with front and rear card cage for 3 U boards according to CompactPCI Stan
dard CPCI Serial (CPCI-S.0)
• 1...9 slot 3 U CPCI Serial backplanes with or without Rear I/O
• 1...2 Power Backplanes with SSI-type connector
• 1...2 CPCI Serial plug-in power supplies (300 W) with wide range input and SSI-type con­nector
• Power input module with IEC 320-C14 connector
,
mains/line switch, mains/line filter and
fuses
• Fan Trays with or without Fan Control Module (FCM) with 3 axial Fans for the active cooling of the boards and the power supplies
Available Configurations
The system 24579-421 is described as an example below in this manual.
The system includes:
- 9 slot CPCI Serial backplane with Rear I/O
- 2 power backplanes
- 2 CPCI Serial PSUs (300 W)
- Fan tray with Fan Control Module (FCM2) and Display.
All pictures in this manual may differ from the latest
series.
1 x 300 W PSU 2 x 300 W PSU
No Fan Control FCM & Display No Fan Control FCM & Display
Slots w/o Rear I/O with Rear I/O w/o Rear I/O with Rear I/O w/o Rear I/O with Rear I/O w/o Rear I/O with Rear I/O
1 On Request On Request On Request On Request On Request On Request On Request On Request
2 On Request On Request On Request On Request On Request On Request On Request On Request
3 On Request On Request On Request On Request On Request On Request On Request On Request
4 On Request On Request On Request On Request On Request On Request On Request On Request
5 On Request On Request On Request On Request On Request On Request On Request On Request
6 On Request On Request On Request On Request On Request On Request On Request On Request
7 On Request On Request On Request On Request On Request On Request On Request On Request
8 On Request On Request On Request On Request On Request On Request On Request On Request
9 24579-416 24579-424 24579-417 24579-423 24579-418 24579-422 24579-419 24579-421
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Safe
ty 3
1.5 System Overview
Figure 1: Front View
12315801
1 PSU 1 6 Front Panel 32 U 2 PSU 2 7 Display 3 Fan Tray 8 9 Slot CPCI-S Backplane 4 Power Backplane 1 9 Fan Control Module (FCM) 5 Power Backplane 2
24579-4xx (CPCI Serial Systems 3+1 U)
4 Safety R1.0, January 2016
Figure 2: Rear View
1.6 Subrack
The 4 U chassis is based on the Schroff europacPRO system with EMC shielding. The front card cage provides 9 CPCI Serial slots.
The lower guide rails of the card cage are equipped with ESD clips.
12315802
1 Temperature Sensor 5 Ground Terminal 2 Front Panel 32 U 6 Power Backplane 2 3 Front Panel 12 U 7 Power Backplane 1 4 AC mains/line module
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Safe
ty 5
1.7 Backplane
Figure 3: Example: 9 Slot Backplane with rear I/O, Systemslot left
24579-4xx (CPCI Serial Systems 3+1 U)
6 Safety R1.0, January 2016
1.8 Topology of a 9 Slot Backplane
The CPCI Serial backplane with 9 slots supports the full set of serial links at all slots.
The serial links (SATA/SAS, USB2/3, PCIe) are arranged as a Single Star architecture.
Ethernet is implemented by 4 differential pairs in Single Star
routing to support 10/100/1000/
10GBase-T.
More information in the Schroff Backplane manual, order no.: 63972-333
Figure 4: Backplane Topology
1
2
3
4
5
6
7
8
2
31 456789
GA[3]=GND GA[2]=GND GA[1]=GND GA[0]=GND
GA[3]=GND GA[2]=GND GA[1]=GND GA[0]=OPEN
GA[3]=GND GA[2]=GND GA[1]=OPEN GA[0]=GND
GA[3]=GND GA[2]=GND GA[1]=OPEN GA[0]=OPEN
GA[3]=GND GA[2]=OPEN GA[1]=GND GA[0]=GND
GA[3]=GND GA[2]=OPEN GA[1]=GND GA[0]=OPEN
GA[3]=GND GA[2]=OPEN GA[1]=OPEN GA[0]=GND
GA[3]=GND GA[2]=OPEN GA[1]=OPEN GA[0]=OPEN
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
7
6
5
4
3
2
1
8
PCIe
SATA
USB 3.0
I2C
ETH
SGPIO
USB 2.0
8x
8x
GA
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Safe
ty 7
1.9 Power Backplane
The Schroff CompactPCI Serial power backplane accepts a pluggable power supply with SSI­type connector. The power backplane provides +12 V payload power and for wake-up events an additional +5 V Standby voltage. More information in the backplane‘s user manual, order no.: 63972-334
Figure 5: Power Backplane
24579-4xx (CPCI Serial Systems 3+1 U)
8 Safety R1.0, January 2016
1.10 Power Supply
The CPCI Serial system is powered by 300 W CPCI Serial plug-in power supplies with wide range input (100 - 240 VAC). They provide 12 V payload power and 5 V standby power for CPCI Serial boards.
The power supplies are plugged-in in dedicated slots at the left front side. The power supply contacts
via
a SSI-type connector to a Power backplane.
The power input is provided by an AC mains/line modu
le with IEC 320-C14 connector,
integrated mains/line fuses and line filter.
The fuse rating is 10 A slow blow
(10AT).
Figure 6: AC mains/line module
Hazardous voltage!
Parts of the power supply may be exposed with hazardous voltage. Always remove mains/ line connector before carry out any assembly work.
Caution!
Your system has not been provided with a AC power cable. Purchase an AC power cable that is approved for use in your country. The AC power cable must be rated for the product and for the voltage and current marked on the product's electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product.
12309010
1 Fuse holder 3 AC Connector (IEC320-C14) 2 Mains/line switch
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Safe
ty 9
1.10.1 CPCI Plug-In AC Power Supply
Figure 7: Power Supply
Tab l e 1 : Data AC Power Supply
e
More information in the user manual order no.: 63972-335
1.10.2 Grounding/Earthing
Input voltage nominal 100 - 240 VAC
Mains Frequency 50 / 60 Hz
Output (max.) 300 W
Output voltages 5.0
12.0VV--
2.5 25A A
Ripple < 1 % Peak/Peak
Cooling Requires Airflow > 10 CFM for 300 W Output
Caution!
The unit is designed in accordance with protection class 1! It must therefore be oper­ated with protective earth/GND connection. Use only a three cond
uctor AC power
cable with a protective earth conductor that meets the IEC safety standards!
24579-4xx (CPCI Serial Systems 3+1 U)
10 Cooling R1.0, January 2016
2 Cooling
The CPCI Serial boards and the power supplies are cooled by forced air convection through three 12 VDC axial fans located in a hot-swappable fan tray.
2 different fan trays are available:
• Fan Tray with Fan Control Module (FCM), status LEDs and RESET button (3 fans with 220 m³/h (130 cfm)).
• Fan Tray with constant speed fans (3 fans with 140 m³/h (85 cfm)).
An air filter is available as an option for both fan trays.
Figure 8: Fan Tray with FCM
The fan speed is determined by a temperature sensor above the card cage. Up to 40 °C the PWM is 20%, from 40 °C to 60 °C the PWM is increased continously from 20% to 100%.
This control characteristics can be changed by a DIP switch on th
e FCM. (See user manual,
order no.: 63972-312)
12315803
1 Display with Status LEDs 2 Fan Control Module
3 RESET Push Button (Grounds the PRST# signal)
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Cooling 11
2.1 Air Filter
An air filter is avalaible as an option. The air filter can be fixed with a mounting frame at the bottom of the fan tray.
The filter meets the requirements of the Telcordia
Technologies Generic Requirements GR-
78-CORE specification.
Figure 9: Fan Tray with Air Filter
2.2 Airflow
Figure 10: Airflow
12315804
1 Air Filter with mounting frame
Caution!
To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane.
12315805
24579-4xx (CPCI Serial Systems 3+1 U)
12 Installation R1.0, January 2016
3 Installation
3.1 General Installation Guidelines
3.1.1 Unpacking
Consider the following when unpacking and storing the system:
• Leave the system packed until it is needed for immediate installation.
• After unpacking the system, save and store the packaging material in case the system mus
t
be returned.
If the packaging is damaged and possible system damage is present, report to the shipper and ana
l
yze the damage.
3.1.2 Ensuring Proper Airflow
• Maintain ambient airflow to ensure normal operation. If the airflow is blocked or restricted, or if the intake air is too warm, an over temperature condition can occur.
• Ensure that cables from other equipment do not obstruct the airflow through the sys­tems.
• Use filler panels to cover all empty chassis slots. The filler panel should include an airflow baff
le that extends to backplane. The filler panel prevents fan air from escaping out of the
front of an open slot.
Caution!
When opening the shipping carton, use caution to avoid damaging the system.
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Installation 13
3.2 Rack-Mounting
This subrack system can be installed in 19“ equipment racks. The rack must be accessible from the front and rear for equipment installation.
Mounting Instructions:
• Ensure that the rack is constructed to support the weight and dimensions of the system.
• Install any stabilizers that came with your equipment rack before mounting or servicing the sy
stem in the rack.
Load the rack from the bottom to the top, with the heaviest system at the bottom, avoid unev
en mechanical loading of the rack.
3.3 Initial Operation
• Ensure that the system has not been damaged during transport, storage or assembly.
• Check the Protective Earth (PE) resistance, should be < 0,1 Ohm.
• Plug-in the boards.
• Cover all open Slots with filler panels.
• Switch on the system.
Warning!
This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This eqipment is designed in accordance with protection cla
ss 1!
It must therefore be operated only with
protective GND/earth connection!
24579-4xx (CPCI Serial Systems 3+1 U)
14 Service R1.0, January 2016
4 Service
4.1 Technical support and Return for Service Assistance
We generally recommend to return the complete system. For all product returns and support issues, please contact your Schroff sales distributor.
We recommend that you save the packing material. Shipping without the original packing material might void the warranty.
4.2 Declaration of Conformity
SCHROFF CompactPCI systems are developed and manufactured according to EN 60950-1.
SCHROFF CompactPCI systems are not end-products with independen
t functionality as described in the definition of the EMC regulations, and therefore a CE marking is not required. However, when CPCI cards are assembled according to specification, the systems fulfill the requirements in accordance with EMC Directive 2004/108/EG and Low-voltage Directive 2006/95/EG.
Interference resistance and interference emissions are
factors which are
heavily influenced by the type and quantity of CPCI cards used in the system assembly. Through the use of high quality line filters and EMC optimized enclosure design, SCHROFF offers CPCI systems which serve as an ideal base for system integrators, which comply with the prescribed limits of EN 6100-6-3 and EN 61000-6-2
The systems are generally equipped with power supplies which possess CE markings in accordance with EN 60950-1, EN 61
000-6-3, EN 61000-6-2).
Before delivery a high-voltage, protective earth and functionality test is carried
out on each
individual system.
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Serv
ice 15
4.3 Scope of Delivery (24579-421)
Please order the power cable separately.
4.4 Accessories
4.5 Spare Parts
On request.
Quantity Description
1 Shielded europacPRO chassis 4 U / 84 HP with front handles
1 CPCI Serial backplane 9 slot 3 U with Rear I/O
2 Power backplanes with SSI-type connector
1 Front card cage for max. 9 boards 3 U 160 mm deep
IEEE guide rails inc. ESD clips)
1 Rear card cage for max. 9 boards 3 U 80 mm deep
IEEE guide rails inc. ESD clips
2 300 W CPCI Serial plug-in pow
e
r supply with input range of 100 VAC to 240 VAC
1 Power input module with IEC 320-C14 connector, mains/line sw
itch, mains/line filter and fuses
1 Complete AC/DC cabling
1 Fan Tray 1 HP with FCM and 3 fans 220 m³/h (140 cfm) each
2 Front panel 3 U, 32 HP
1 Front panel 3 U, 12 HP
Order No. Description
20848-75x Front panels for Rear I/O Boards, dimensions see catalogue
24579-632 Air filter mounting frame
60713-471 Air filter
20848-7xx Slot covers with front panel and EMC shielding for v
a
cant slots. For dimensions, please see catalogue.
34562-8xx Slot covers for vacant slots. For dimensions, please see catalogue.
24579-03x Printed Circuit Board covers (solder side cover
s
). For dimensions, please see catalogue
24579-4xx (CPCI Serial Systems 3+1 U)
16 Technical Data R1.0, January 2016
5 Technical Data
Tab l e 2 : Technical Data
Dimensions
Height 177 mm (4 U)
Width 482.60 mm (19“)
Depth (Card cage) 275 mm
Depth (Overall with handles)
330 mm
Weight
Completely assembled approx. 9 kg
Power Supply
Input Voltage 100 VAC bis 240 VAC
Frequency 50 / 60 Hz
Power input
up to 600 W
Ambient Temperature
Operation +0 °C to +50 °C
Storage
-40 °C to +85 °C
Humidity
Admissible humidity 30 % to 80 %, non-condensing
EMC, fulfils requirements for:
Transient Emissions
EN 61000-6-3
Interference Resistance
EN 61000-6-2
Safety
Test voltages according to EN 60950-1 Input - Output:
Input - PE: Output - PE: Output - Output:
4,3 kVDC 2,2 kVDC 0,7 kVDC 0,7 kVDC
Shock and vibration:
EN 60068-2-6 and EN 60068-2-27
Electromagnetic Shielding
Shielding attenuation typ. 40 dB at 1 GHz if shielded front
panels are used.
24579-4xx (CPCI Serial Systems 3+1 U)
R1.0, January 2016 Dimensions 17
6 Dimensions
Figure 11: Dimensions
3 U -32 HP
465,80
482,60
282,00
330,00
3 U
177,00 = 4 U
3 U -32 HP
3 U -12 HP
150,00 45,00
24579-4xx (CPCI Serial Systems 3+1 U)
18 Dimensions R1.0, January 2016
Schroff GmbH
Langenalber Str. 96 - 100 75334 Straubenhardt, Germany Tel +49.7082.794.0 Fax +49.7082.794.200
schroff.nVent.com
Loading...