Nuvo NV-E6DMS-DC, NV-E6DXS-DC User Manual

Page 1
Page 2
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
Danger Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposures:
DURATION PER DAY (HOURS)86432 1
SOUND LEVEL (dB) 90 93 95 97 100 103
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF NON-INSULATED "DANGEROUS VOLTAGE" WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATINGAND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATUREACCOMPANYING THE UNIT.
APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS.
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE CHASSIS. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
1. Read all safety and operating instructions before using this product.
2. All safety and operating instructions should be kept for future reference.
3. Read and understand all warnings listed on the operating instructions.
4 . Follow all operating instructions to operate this product.
5. This product should not be used near water, i.e. bathtub, sink, swimming pool, wet basement, etc.
6. Only use dry cloth to clean this product.
7. Do not block any ventilation openings, It should not be placed flat against a wall or placed in a built-in enclosure that will impede the flow of cooling air.
8. Do not install this product near any heat sources ; such as, radiators, heat registers, stove or other apparatus (including heat producing amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding­type plug. Apolarized plug has two blades with one wider than the other.Agrounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord being walked on or pinched, particularly at plugs, convenience receptacles and the point where they exit from the apparatus. Do not break the ground pin of the power supply cord.
11 . Only use attachments specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation ports or any other openings.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way; such as, power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
1
Page 3
FRENCH
Danger L‘exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l’audition, Chaque organisme humain reagit differemment quant a la perte de l’audition, mais quasiment tout le monde subit une diminution de I’acuite auditive lors d’une exposition suffisamment longue au bruit intense. Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits:
DURE EN HEURES PAR JOUR 8 6 4321 INIVEAU SONORE CONTINU EN dB 90 93 95 97 100 103
Selon les autorites, toute exposition dans les limites citees ci-dessus, peuvent provoquer certaines pertes d’audition. Des bouchons ou protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors de l’utilisation de ce systeme d’amplification afin de prevenir le risque de perte permanente de l’audition, Dans le cas d’expositions superieures aux limites precitees il est recommande, afin de se premunir contre les expositions aux pressions acoustiquese I evees potentielIement dangeure u ses, aux personnes exposees aux equipements capables de delivrer de telles puissances, tels ce systeme d’amplification en fonctionnement, de proteger l’appareil auditif.
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
ATTENTION:AFIN DE LlMlTER LE RISQUE DE CHO ELECTR/QUE, NE
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES DOCUMENTS FOURNIS AVEC CE PRODUIT.
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE ELECTRIQUE, NE PAS EXPOSER CETAPPAREILA LA PLUIE OU A L'HUMIDITE.
PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR. CONFER LE SERVICE APRES-VENTEAUX REPARATEURS
IMPORTANTES INSTRUCTIONS DE SECURITE
1. Lire avec attention toutes les recommandations et précautions
d'emploi avant d'utiliser ce produit.
2. Toutes les recommandations et précautions d'emploi doivent être
conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les avertissements énumérés dans les
précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par exemple
baignoires, éviers, piscine, sous-sol humides ... Etc.
6. Utiliser exclusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le
produit tout contre un mur ou dans une enceinte fern gênerait le flux d'air nécessaire au refroidissement.
8. Ne pas placer le produit près de toute source de chaeur telle que
radiateurs, arrivées d'air chaud, fourneaux ou autres appareils générant de la chaleur (incluant les amplificateurs producteurs de chaleur) .
9. Ne pas négliger la sécurité que procure un branchement polarisé
ou avec raccordement à la terre, Un branchement polarisé comprend deux fiches dont l'une est plus large que l'autre. Un branchement à la terre comprend deux fiches plus une troisième reliée à la terre. Si la fiche secteur fournie ne s'insert pas dans votre prise de courant. consulter un 'électricien afin de remplacer votre prise obsolète.
Protéger
10. le cordon d'alimentation de tout écrasement ou
pincement, particulièrement au niveau des fiches, des réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas casser la fiche de terre du cordon d'alimentation.
11. Utiliser uniquement les accessoires spécifiés par le constructeur.
12. Utiliser uniquement avec le chariot de transport, le support, le
trépied, la console ou la table spécifiés par le constructeur ou vendus avec l'appareil. Lors de l'utilisation d'un chariot, bouger avec précaution l'ensemble chariotlappareil afin d'éviter les dommages d'un renversement.
13 Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé
pendant une longue période.
14. Des précautions doivent être prises afin qu'aucun objet ne tombe
et qu'aucun liquide ne se répande à l'intérieur de l'appareil par les orifics de ventilation ou n'importe quelle autre ouverture.
15. Pour toutes interventions techniques s'adresser à un technicien
qualifié.L'intervention technique est nécessaire lorsque l'appareil a été endommagé de n'importe quelle façon, comme par exemple si le cordon secteur ou sa fiche sont détériorés,si du liquide a coulé ou si des objets sont tombés à l'intérieur de l'apparei1,si l'appareil a été exposé à la pluie ou à l'humidité, s'il ne fonctionne pas normalement ou s'il est tombé.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc
electrique ne pas exposer l'appareil à la pluie ou à l'humidité.
ée, cela
2
Page 4
Introduction
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CCCCC
Congratulations on your purchase of the NuVo Essentia System. Essentia brings the best of today's digital technology to a true whole­home audio system. Listening to multiple audio sources from independent zones throughout the home has never been easier or more affordable.
The elegant keypads allow independent selection of up to six different audio sources from up to twelve zones in the home.Each ship including white, almond, ivory and black inserts and trim plates to match a variety of decorating choices. Generation D digital amplification provides clear, precise digital sound to each zone without the heat generated by traditional analog amplification. The integrated infrared repeater in each keypad means you can control all of your audio sources wirelessly from any zone of your home.
Enjoying quality audio throughout the home is simple and affordable with Essentia. This installation manual is designed to provide a sequential, step-by-step guide to making full use of the many features and capabilities of the Essentia System.
Package Contents:
E6DMS-DC Main System 1 NV-E6DM2 Six-Source, Six-Zone Amplifier 6 NV-E6DKP-DC Decora style Zone Controller Keypads
®*
including white, almond, ivory and black. 1 NV-LRC1 Learning Remote Control 1 NV-E6DEZP Decora EZ Port Multi-port connection hub
®
1 NV-NEC Network connection cable 6 NV-VEC IR emitters with feedback LED 1 NV-PC1 IEC 3-wire power cable
Zone/Room 1 Zone/Room 2 Zone/Room 3 Zone/Room 4 Zone/Room 5 Zone/Room 6
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
E6DXS-DC Expander System 1 NV-E6DMS Six-Source, Six-Zone Amplifier 6 NV-E6DKP-DC Decora style Zone Controller Keypads
®
including white, almond, ivory and black 1 NV-LRC1 Learning Remote Control 1 NV-SRC 1 Source Link Cable 1 NV-DNK1 Data Link Cable 1 NV-PC1 IEC 3-wire power cable
*Decora is a registered trademark of the Leviton Corp.
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
EZ Port Cat-5 connection
CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC
MODELNV-P2100
HIGHEFFICIENCY200WATT
STEREOAMPLIFIER
WATTS
120V
250
60HZ
NuVoTechnologiesCincinnatiOhio. USA
AUDIO
L
SENSITIVITY
OdBV=1.0RMS
ON/OFFSWITCH
LEFT
RIGHT
INPUT
AUDIO AC/DC
0
0
2
R
-12
-12
+6
OUTPUT
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
135
4
2
6
EMITTEROUTPUTS
+6
OUTPUTPOWER
20W/6OHMX2
SUM1
SUM2
3
INPUT
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE1
1234 5
1234 5
Source 1 Tuner 1
Source 2 Tuner 2
OUTPUTPOWER
20W/6OHMX2
SOURCEINPUTS
Audio Out
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE2
6
6
OUTPUTPOWER
20W/6OHMX2
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
SOURCELINK
Source 3 Tuner 3
Audio Out
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE3
OUTPUTPOWER
20W/6OHMX2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE4
Audio Out
Source 4 CD 1
OUTPUTPOWER
20W/6OHMX2
1
5
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE5
13
24
ZONETRIGGER OUTPUTS
OUTPUTPOWER
20W/6OHMX2
5
6
Source 5 CD 2
Audio Out
CONTROL
CONTROL
VOLTAGE
POWER
TRIGGER
MODE
3-30VOLTS
ACORDC
Essentia D
SYSON
EXT.MUTE
SYSTEM
Audio Out
Source 6 Sat.
V.II
UNIT ON
+12VDC 100mA
CONNECTTO NV-E6DEZP
USENV-NC1
CABLE
NETWORK
SPEAKER
OUTPUTPOWER
8OHM:70W X 2 4OHM:100W X 2
RS-232
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
DIGITALLINK
USEONLYWITH250V FUSEUSEONLYWITH250V FUSE
USEONLYWITH 250V FUSE
MODELNV-E6DM2
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz 500W
NuVoTechnologiesHebronKY USA
www.nuvotechnologies.com
CONFORMSTO
R
ULSTD.6500
CERTIFIEDTO
US
C
CAN/CSASTD.E60065
3033118
Audio Out
Diagram shown with optional NuVo
FUSE:T5A
NV-P2100 auxiliary amplifier powering zone 6.
Essentia D Wiring Diagram
Single Network cable connection to the Essentia Amplifier
Page 5
POWER
STANDBY
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
V.II
1
2
Essentia Front Panel
1. POWER Button:
2. STAND BY LED:
3. Zone Status LED's:
The amplifier is designed to be turned on and remain on. The power button supplies power to the system. Each zone can then be turned on or off independently. The amplifier should be turned on before any external connections are made. This activates internal protective circuitry. When lit, this blue LED (light-emitting diode) indicates that the amplifier is plugged into an AC power outlet source. These LED's indicate the power status of each zone. When a zone LED is lit, it indicates that the zone is currently turned on.
3
1
VOLUME
2
6
TNR1
TNR2
SAT1
MUTE
CD
HD
SAT2
3
4
5
Keypad Features
1. Volume Level
2. Power
3. Volume
4. IR Receiver
5. Mute
6. Source Selection
The level of the zone volume is indicated by these LEDs (light-emitting diodes). The power button turns that keypad's zone on and off independently of the other zones. Pressing and holding the power button turns all zones off simultaneously. Independent audio volume level for each zone is controlled with these buttons. Each keypad has an IR (infrared) receiver located under the volume button for wireless control of the audio source equipment. The mute button temporarily silences any audio playing in that keypad's zone. The source buttons independently select any of the six sources connected to the Essentia amplifier. The selected source button will remain lit.
4
Page 6
VARIABLE
OUTPUT
OUTPUT POWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE 1
12 345
12 345
SOURCE INPUTS
ZONE 2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUT POWER
6
6
20W/6OHMX2
ZONE 3
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
SOURCE LINK
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUT POWER
20W/6OHMX2
ZONE 4
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUT POWER
20W/6OHMX2
1
5
ZONE TRIGGEROUTPUTS
VARIABLE
OUTPUT
RING=R
OUTPUT
ZONE 5
1
3
24
TIP=L
FIXED
OUTPUT POWER
20W/6OHMX2
135
5
2
6
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE 6
4
6
EMITTER OUTPUTS
OUTPUT POWER
20W/6OHMX2
SUM1
SUM2
Essentia D
SYS ON
EXT.MUTE
SYSTEM
V.II
CONNECTTO
NV-E6DEZP
USENV-NC1
CABLE
NETWORK
RS-232
PROGRAM
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
DIGITALLINK
MODEL NV-6DM2
SIXSOURCESIX ZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz 500W
NuVoTechnologiesHebron KY USA
www.nuvotechnologies.com
CONFORMSTO
R
ULSTD.6500
US
C
CERTIFIEDTO
CAN/CSASTD.E60065
3033118
FUSE:T5A
1
Essentia Back Panel
1. Audio Source Inputs:
2. Source Link:
3. Variable Lineout:
4. Fixed Lineout:
5. Speaker Outputs:
6. Zone Triggers:
7. Emitter Outputs:
8. System On:
9. External Mute:
10. Network Input:
11. Digital Link:
12. RS232 Port:
13. AC Power:
The Essentia amplifier accepts up to six audio sources. A source consists of any audio component capable of supplying a line level signal. This multi-pin connection is used to transfer the audio information from the Essentia main amplifier to the expander amplifier. This output is used to expand the system to twelve zones. The source link connection cable is provided with the Essentia D Expander package. The variable lineout is intended for zones where additional amplification is needed and the Essentia keypad is used to control the volume of all the speakers in that zone. The fixed lineout is intended for zones where additional amplification and separate volume control are needed. Individual stereo speaker outputs for each zone provide 20 watts output per channel. These outputs provide a 12-volt output when the corresponding zone is turned on. This is used to trigger external equipment specific to a given zone. These outputs transfer IR (infrared) signals, repeated from a zone keypad, from the Essentia amplifier to the audio source equipment. There are six source specific outputs and two “sum” output that sends IR signals regardless of the selected source. This output provides a constant 12-volt output when any zone is turned on. This is used to trigger external devices. This is designed to mute any audio playing through the system when the phone or doorbell rings. This RJ-45 connection is the input for all zone information coming from the Essentia keypads. The connection is made using the Network Cable supplied with the package. This multi-pin connection transfers all the digital information from the main amplifier to the expander amplifier. This output is used to expand the system from six to twelve zones. The Digital Link connection cable is provided with the Essentia D Expander package. The RS232 serial port allows two-way communication for control by a home automation system. A detachable power cable supplies power to the Essentia System from any AC outlet.
2
3
4
5
6
7
8
9
10 11
12
13
5
Page 7
LRC1 Learning Remote Control
1
2
3
4
5
1. Setup:
The setup button is used to place the remote control in program/learn mode.
3
7
2
1
4
MUTE
E
C
UR
O
S
5
6
M
M
E
E
O
O
C
C
H
H
-
-
O
O
N
N
E
E
T
T
L
L
O
O
H
H
W
W
VOL-
R
R
O
O
L
L
VOL+
ON/OFF
2. Whole-Home Control:
3. Transport Buttons:
This section automatically performs the basic Essentia keypad functions.
The transport buttons perform basic source specific functions, such as play, stop, pause, forward and reverse.
4. Video Source Control:
These buttons are typically used by video equipment for menu navigation and selection.
5. Source Volume:
This is source specific volume control, such as a TV or stereo receiver. This is not used for NuVo zone volume.
8
6. Numeric Buttons:
These buttons provide source specific direct numeric access.
6
M1
M5
M2
M6
NV-LRC1
7. Power Button:
This power button is for source specific power on and off. It is not for NuVo zone on and off.
M4
M3
M7
M8
9
8. Channel up and down:
This button provides source specific channel scrolling.
9. Macro Buttons:
These buttons do not perform a given source function. They can be used for programming multiple function macro commands.
6
Page 8
Installing the Essentia System in Your Home
I. Prewire
The Essentia System uses CAT5 cable for keypad control and either two or four-conductor 16-gauge speaker wire. All the wire is “homerun” from each zone to the location of the Essentia amplifier and Audio Source equipment.
Complete CAT5 Crimping Instructions
The NuVo audio systems require CAT5, unshielded, twisted pair (UTP), for communication between the keypads/Display Pads and the main amplifier unit. Each end of the wire is terminated with an RJ45 connector.
The Essentia System can accommodate 2,000 total feet of CAT5 cable. For the most reliable operation, it is best that no single run of CAT5 exceeds 250 feet.
The correct wiring scheme for the CAT5 cable is standard EIA/TIA 568A. Properly terminating the CAT5 cable is crucial for the operation of the system. It is very important to use a good quality crimp tool, and test each end to end run with a CAT5 wire tester to insure that your system operates flawlessly, fig.1.
Step-by-Step Crimping Instructions:
1. Strip a 2 to 3 inch portion of the insulation, exposing the 4 twisted pairs.
2. Untwist the wires and fan them out individually. Arrange the wires into the correct color scheme as shown in Fig. 1.
3. Flatten the wires in their correct order, and trim them evenly across the top. Most crimp tools have a wire trimmer built-in. It is best to trim the wires to about ½” in length.
4. While holding the wires flat between your thumb and forefinger, insert the wires into the RJ45 connector, so each is in its own slot. Push the wire into the RJ45, so all 8 conductors touch the end of the connector. The insulation jacket should extend beyond the crimp point of the RJ45.
5. Insert the RJ45 into the crimp tool receptacle and squeeze the tool firmly. Note that a ratchet type tool should tighten down until it no longer clicks.
6. The RJ45 should be firmly crimped to the CAT5 insulation. It is necessary that the color scheme be repeated identically on each end of the wire.
Ground
Top view with tab down.
12345678
Pair 2
Fig. 1: EIA 568A wiring scheme for CAT5 Cable
Pin #
1. Green Stripe
2. Green
3. Orange Stripe
4. Blue
5. Blue Stripe
6. Orange
7. Brown Stripe
8. Brown
Note: Colors listed as “stripe” are a white wire with a colored stripe.
Control Data Bus+
Control Data Bus-
Ground
IR TX
Pair 1
Pair 3
Wires insert from this end.
Step 1 Step 2 Step 3
Step 4 Step 5 Step 6
IR Active
Pair 4
Ground
+12V Power
7
Page 9
II. Installing the Essentia Amplifier
System setup works best when the amplifier is placed in the same location as the audio source equipment. This is typically in an audio rack, entertainment center or a closet dedicated to housing the home audio/video equipment.
The amplifier should be plugged in and the power button on the front panel should be depressed before proceeding with the rest of the installation.
the Essentia System.
This activates the internal protective circuitry of
II. Terminating Speaker Wire
The speaker wire for each zone is terminated in a standard Euro­style connector that plugs into each zone specific amplified output. The common speaker termination scheme is Left - Left +, Right - Right +. Either two or four-conductor 16-guage wire is recommended. Larger than 14-guage wire will not fit into the euro connector.
To terminate the speaker wire, strip back the outer jacket and expose the inner conductors. Strip approximately 1/4” (4 mm) of the insulation from the inner conductors exposing the copper wire. Place the exposed wire in the euro connector and tighten the screw down terminals, fig. 2.
Once you have plugged the Cat-5 wires into the EZ Port, screw the EZ Port into its construction bracket using the supplied mounting screws.
Fig. 2
LEFT
-
LEFT
+
RIGHT
-
RIGHT
+
Be careful not to allow the exposed wire from each conductor to touch the adjacent conductor. This will short the speaker input. Each speaker output is designed for two 8-Ohm speakers. Overloading the amplifier could cause it to overheat and do damage to the output.
III. Installing the NV-E6DEZP EZ Port
The EZ Port is a multi-connection hub designed to accept all the CAT5 wires from the keypads in the system. The location of the EZ Port should be determined by the location of the Essentia amplifier. It is best to place in the wall behind the amplifier that would be easily accessible if necessary.
The EZ Port fits easily in any dual-gang size construction bracket with an open back. These are often referred to as “mud rings”. Simply plug the terminated CAT5 wires into any of the sixteen available jacks on the back of the EZ Port, Fig. 3. The order in which the individual CAT5 wires are plugged is in not important, although it is strongly recommended that you label the CAT5 with the appropriate zone number for future reference.
Fig. 3
8
Page 10
IV. Connecting the EZ Port to the Essentia amplifier
When the EZ Port is installed in the wall the only part visible should be the faceplate and a single RJ45 jack. The supplied pre­terminated network cable can then be plugged into the jack on the EZ Port and into the network connection on the back of the Essentia amplifier, Fig. 4. Any CAT5 cable terminated using 568A or 568B network wiring will suffice should you need a longer connection.
V. Attaching Audio Source Equipment to the Essentia Amplifier
Each piece of audio source equipment is connected to the Essentia amplifier with standard stereo RCA cables. Attach the RCA cable to the corresponding audio output on the source equipment and to the desired source input on the back of the Essentia amplifier, Fig. 5.
Fig. 4
Fig. 5
EZ Port (front)
NV-E6D EZ Port
Model NV-E6DEZP
Connect to NV-E6DM
Audio Distribution Amplifier
Network Cable
VARIABLE
OUTPUT
OUTPUT POWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE 1
ZONE 1
12 345
12 345
SOURCE INPUTS
ZONE 2
ZONE 2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
Essentia Network Connection
SYSON
EXT.MUTE
SYSTEM
OUTPUT POWER
20W/6OHMX2
6
6
CONNECTTO
NV-E6DEZP
USENV-NC1
CABLE
NETWORK
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
SOURCE LINK
CONNECTTO
USENV-SLC1
DIGITALLINK
VARIA BLE
ZONE 3
ZONE 3
PROGRAM
NV-E6DX
CABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUT POWER
20W/6OHMX2
VI. Connecting the IR Emitters
IR commands for the source equipment are transferred from the Essentia amplifier to the source equipment via mini IR mouse emitters. Six of these are supplied with your Essentia System. The emitter is plugged into the corresponding source IR output on the Essentia and then placed over the IR receiver window on the source component, fig. 6. The IR outputs are individually routed to sources 1-6 allowing IR commands from the chosen source to only control that source.
The two SUM outputs will flash any IR command that is sent from any of the zones. This is used to connect the NuVo T2 Tuner, which has a single IR direct input to control both tuners to the Essentia System or an IR blaster designed to flash IR commands to a variety of components. This is done by plugging a single mono 1/8” patch cable into the SUM IR output and into the Direct IR input.
Fig. 6
Source 1 Tuner 1
Audio Out
9
Page 11
VII. Expanding Essentia to 12 Zones
Six additional listening zones can be added to the Essentia System using the Essentia Expander package. The expansion is easily done using the Source Link and Digital Link multi-pin outputs on the Essentia main amplifier, Fig. 7.
The necessary cables for this are supplied with the Expander package. No other connections are necessary with the exception of the AC power cord and the additional speaker terminations. The additional CAT5 wires for the zones 7-12 plug into the EZ Port.
VIII. Installing the Essentia Keypads
You are now ready to install the keypads and complete the Essentia installation. This is easily done using a rotary switch located on the back of the keypad to set a specific zone address for each keypad, Fig. 8.
Fig. 7
Fig. 8
VARIABLE OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE71
ZONE8
VARIABLE OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE1
1234 5
1234 5
ZONE2
SOURCEINPUTS
Source Link Cable
VARIABLE
VARIABLE
VARIABLE
VARIABLE
OUTPUT
OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE9
CONNECTTO
NV-E6DM2
USENV-SLC1
CABLE
SOURCELINK
VARIABLE OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE3
6
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
6
SOURCELINK
OUTPUT
OUTPUTPOWER
20W/6OHMX2
OUTPUTPOWER
20W/6OHMX2
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE10
ZONE11
8
7
1
5
10 11
ZONETRIGGER OUTPUTS
VARIABLE OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE4
ZONE5
1
2
1
5
45
ZONETRIGGER OUTPUTS
TIP=L
RING=R
FIXED
OUTPUT
VARIABLE OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUT
TIP=L RING=R
FIXED
OUTPUT
VARIABLE
OUTPUT
TIP=L RING=R
FIXED OUTPUT
OUTPUTPOWER
20W/6OHMX2
9
12
OUTPUTPOWER
20W/6OHMX2
123
3
4
6
VARIABLE
OUTPUT
TIP=L RING=R
FIXED OUTPUT
ZONE12
VARIABLE
OUTPUT
RING=R
OUTPUT
ZONE6
5
EMITTEROUTPUTS
OUTPUTPOWER
20W/6OHMX2
MODELNV-6DX
CONNECTTO
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
NV-E6DM2
FUSE:T5A
120V 60Hz500W
NuVoTechnologiesHebronKYUSA
www.nuvotechnologies.com
USENV-SLC1
CABLE
CONFORMSTO
R
ULSTD.6500
US
C
CERTIFIEDTO
CAN/CSASTD.E60065
DIGITALLINK
3033118
OUTPUTPOWER
TIP=L
20W/6OHMX2
FIXED
SUM1
SUM2
6
Essentia D
SYSON
EXT.MUTE
SYSTEM
RS-232
V.II
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
DIGITALLINK
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz500W
NuVoTechnologiesHebronKYUSA
www.nuvotechnologies.com
R
US
C
CAN/CSASTD.E60065
3033118
MODELNV-6DM2
FUSE:T5A
CONFORMSTO
ULSTD.6500
CERTIFIEDTO
CONNECTTO
NV-E6DEZP
USENV-NC1
NETWORK
CABLE
Data Link Cable
0
1
F
2
3
E
4
D
5
C
6
7
B
8
A
9
The switch requires the use of a small flat screwdriver and is set by turning the arrow insert on the switch to the appropriate zone number. Zones 1-12 are set by using switch positions 1-C (note that zones 10, 11 and 12 are denoted by A, B and C respectively). Switch positions D, E, F and 0 are for additional keypads in zones 1-4.
It is important to note that the keypads will not function properly unless each has its own unique zone address.
Once each keypad’s zone address is set, the CAT5 can be plugged in and the keypad installed in the wall.
Zone
Address
WARNING:
AVI S:
NuVoTechnologies LLC Hebron, Kentucky USA
www.nuvotechnologies.com
Local Source
Essentia Keypad
Model NV-E6DKP-DC
Use
only with
Essentia
NuVo System
Utiliser uniquementavec
NuVo System
Essentia
Network
Connection
10
Page 12
IX. Keypad Zone Settings
Each Essentia keypad has the ability to set specific zone functions. These are bass and treble EQ, source grouping, all on (party mode) and volume reset. Each of these functions is accessed by pressing the MUTE and SOURCE 1-5 buttons simultaneously, fig. 9. While the keypad is in the function set mode, the appropriate source button with flash. To return to normal zone control, press the flashing source button.
Fig. 9
Source 1
Source 3
Source 5
TNR1
TNR2
SAT 1
VOLUME
MUTE
SAT2
The volume indicator LED indicates the function being set.
Press the Mute and Source 1-5 buttons to initiate each zone function.
CD
Source 2
HD
Source 4
EQ Control and Source Grouping
To change bass response, press the Mute button and Source 1 button simultaneously. Adjust the bass level up or down by using the Volume Up and Volume Down buttons. The volume indicator LEDs will indicate the output level, fig. 8. Adjust treble response using the same process. This is accessed by pressing the Mute and Source 2 buttons. Once the desired setting is made, press the Source button again to return the keypad to normal operation.
Source grouping is a feature that allows multiple zones in an open living space to always share the same source selection but still retain individual volume and on/off control. This is achieved by pressing Mute and Source 3. Volume Up enables the group function, and Volume Down disables the group function and causes the keypad to operate independently of all other groups, fig. 10.
Fig.10
Fig. 11
-6 dB
-8 dB
Group Disabled
-4 dB
VOLUME
VOLUME
FLAT
+4 dB
+6 dB
+8 dB
Group Enabled
11
Page 13
All On/Party Mode
The Essentia System has an All On feature. Any keypad within the system, which can be up to twelve zones, has the ability to become a master control for the entire house. The master keypad will control zone on, volume level, and source selection for all other zones.
Fig. 12
The lit volume LED will flash when the keypad is in Master Mode.
To place a keypad in Master Mode function, simply press the Mute and Source 4 buttons simultaneously. This will cause the volume indicator LED for that zones keypad to flash continuously and adjust to a preset volume level (-60 dB). All other zones will then turn on to the same relative volume level and increase or decrease with the volume adjustment on the master keypad, fig. 12. Each keypad volume LED indicates a preset meter level threshold, fig. 13.
Any of the other zone keypads have the ability to override the master function by selecting a new source, changing a local zones volume control, or by turning a local zones keypad off and back on.
The master mode is turned off by repeating the sequence of pressing the Mute and Source 4 buttons.
Volume Reset
Each zone has the capability of turning on at two different volume level settings. At factory default the zone will turn on at the previous listening level. If desired, you can change that default to a low level volume reset regardless of the previous level.
Fig. 13
-54 to -39 dB
-78 to -55 dB
VOLUME
TNR1
TNR2
SAT 1
Source 4
-38 to -29 dB
MUTE
CD
HD
SAT2
-28 to -19 dB
VOLUME
Press the Mute and Source 4 buttons to initiate the Master Mode.
-18 to -13 dB
-12 to -7 dB
-6to0dB
To change the zone to volume reset mode, press the Mute and Source 5 buttons simultaneously. The Source 5 button will begin flashing. The volume LED will first appear at the far left indicating no volume reset. Pushing the Volume Up button will cause the volume LED to move to the far right position. This now indicates that the zone is in volume reset mode, fig. 14.
To return to normal keypad operation, press the Source 5 button again and it will stop flashing. In the volume reset mode the zone will automatically turn on at a preset -60 dB level. The volume reset can be turned off by repeating the above steps and returning the volume LED to the far left position.
12
Fig. 14
Volume Reset Off
Volume Reset On
VOLUME
Page 14
X. Using the Fixed and Variable Lineouts
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CCCCC
C
Each zone of the Essentia amplifier has two 3.5mm mini stereo outputs. These are fixed and variable lineouts used for adding additional amplification when necessary for each zone. A distinct advantage to the NuVo equipment is the ability to use the amplified output, variable and fixed lineouts all simultaneously on all zones. The Essentia amplifier has zone trigger outputs that provide a 12V trigger for additional amplification. This enables the attached amplifier to be triggered on and off with the zone keypad.
Zone Variable Lineout
The variable lineout is designed to allow additional audio amplification volume level to be controlled from that zone’s keypad. When used in conjunction with the zone amplified output, fig. 15, all the speaker’s volume will track with the keypad volume level.
Fig. 15
Zone/Room 1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
The Zone keypad controls the audio volume.
Diagram shown using the NuVo P2100 amplifier
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED
OUTPUT
ZONE1
1234 5
1234 5
SOURCEINPUTS
20W/6OHMX2
ZONE2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
6
6
20W/6OHMX2
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
SOURCELINK
ZONE3
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
20W/6OHMX2
ZONE4
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
20W/6OHMX2
13
1
5
24
ZONETRIGGER OUTPUTS
ZONE5
INPUT
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
L
R
OUTPUT
OUTPUTPOWER
20W/6OHMX2
5
6
AUDIO
SENSITIVITY
OdBV= 1.0RMS
RIGHT
LEFT
INPUT
0
2
-12 +6
+6
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
135
4
2
EMITTEROUTPUTS
0
6
-12
OUTPUTPOWER
POWER
MODE
ON/OFFSWITCH AUDIO AC/DC
20W/6OHMX2
SUM1
SUM2
CONTROL
CONTROL
VOLTAGE TRIGGER
UNIT
+12VDC
3-30VOLTS
100mA
ACOR DC
MODELNV-6DM
SIXSOURCESIX ZONE
AUDIODISTRIBUTIONSYSTEM
Essentia D
SYSON
EXT.MUTE
SYSTEM
ON
V.II
CONNECTTO
NV-E6DEZP
USENV-NC1
NETWORK
CABLE
SPEAKER
OUTPUT POWER
8OHM: 70W X 2 4OHM: 100W X 2
RS-232
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
DIGITALLINK
CABLE
MODELNV-P2100
HIGHEFFICIENCY200 WATT
STEREOAMPLIFIER
120V
60HZ
NuVoTechnologiesCincinnati Ohio. USA
USEONLYWITH 250V FUSE
USEONLYWITH 250V FUSE
120V 60Hz 500W
NuVoTechnologiesHebron KYUSA
www.nuvotechnologies.com
R
US
C
3033118
WATTS
250
MODELNV-6DM2
SIXSOURCESIX ZONE
AUDIODISTRIBUTIONSYSTEM
FUSE:T5A
CONFORMSTO
ULSTD.6500 CERTIFIEDTO
CAN/CSASTD.E60065
CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC
Source 1 Tuner 1
Audio Out
13
Page 15
Zone Fixed Lineout
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
In some zone applications, it is more advantageous to have a separate volume control on the additional speakers being driven by an additional amplifier. This is common with outdoor zones. The fixed lineout offers the capability to add amplification, but the audio signal is not affected by the zone keypad volume level. Therefore, it requires a separate volume control for those speakers, fig. 16.
Fig. 16
Zone/Room 1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
Additional speakers are controlled by a separate volume control.
Diagram shown using the NuVo P2100 amplifier
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED
OUTPUT
ZONE1
1234 5
1234 5
SOURCEINPUTS
Source 1 Tuner 1
20W/6OHMX2
Audio Out
ZONE2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
6
6
20W/6OHMX2
CONNECT TO
NV-6DX
USE NV-SLC1
CABLE
SOURCELINK
ZONE3
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
20W/6OHMX2
ZONE4
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
20W/6OHMX2
13
1
5
24
ZONETRIGGER OUTPUTS
ZONE5
INPUT
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
L
R
OUTPUT
OUTPUTPOWER
20W/6OHMX2
5
6
AUDIO
SENSITIVITY
OdBV= 1.0RMS
RIGHT
LEFT
INPUT
0
2
-12
+6
+6
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
135
4
2
EMITTEROUTPUTS
0
6
-12
OUTPUTPOWER
POWER
MODE
ON/OFFSWITCH AUDIO AC/DC
20W/6OHMX2
SUM1
SUM2
CONTROL
CONTROL
VOLTAGE TRIGGER
3-30VOLTS ACOR DC
Essentia D
SYSON
EXT.MUTE
SYSTEM
UNIT
ON
+12VDC 100mA
V.II
CONNECTTO
NV-E6DEZP
USENV-NC1
CABLE
NETWORK
SPEAKER
OUTPUT POWER
8OHM: 70W X 2 4OHM: 100W X 2
RS-232
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
DIGITALLINK
CABLE
MODELNV-P2100
HIGHEFFICIENCY200 WATT
STEREOAMPLIFIER
120V
60HZ
NuVoTechnologiesCincinnati Ohio. USA
USEONLYWITH 250V FUSEUSEONLYWITH 250V FUSE
USEONLYWITH 250V FUSE
120V 60Hz 500W
NuVoTechnologiesHebron KYUSA
www.nuvotechnologies.com
R
US
C
3033118
WATTS
250
MODELNV-6DM2
SIXSOURCESIX ZONE
AUDIODISTRIBUTIONSYSTEM
FUSE:T5A
CONFORMSTO
ULSTD.6500 CERTIFIEDTO
CAN/CSASTD.E60065
CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC CCC
14
Page 16
XI. The NV-LRC1 IR Remote Control
The Essentia System comes with the NV-LRC1 Learning Remote Control. This remote allows wireless control of all keypad functions, as well as the functions of the audio source equipment. Each NuVo zone keypad has an IR receiver that captures the specific source commands from any remote control and in turn sends the command ultimately to the appropriate source equipment. Embedded IR code libraries makes use of the LRC1 with a large variety of audio and video equipment easy. For complete setup and functionality refer to the User Guide included with the remote control. Additional remote controls are available from NuVo.
XII. NV-MI1 Mute Interface Adapter
The Mute Interface is used in conjunction with System Mute input in the back of the Essentia amplifier. It acts as a relay for a voltage from up to two phone lines and two doorbell transformers. When a voltage is presented to the MI1 it then sends a contact closure to the Essentia System, which in turn causes the system to mute momentarily. This is useful in allowing the telephone ring or doorbell to be heard when audio is playing in any of the zones, Fig. 17.
Fig. 17
20W/6OHMX2
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED OUTPUT
ZONE2
6
L
L
R
R
6
20W/6OHMX2
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
SOURCELINK
ZONE3
VARIABLE
OUTPUT
RING=R
OUTPUT
VARIABLE
OUTPUT
ZONE4
RING=R
OUTPUT
OUTPUTPOWER
TIP=L
FIXED
OUTPUTPOWER
20W/6OHMX2
TIP=L
FIXED
VARIABLE
OUTPUT
ZONE5
RING=R
OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
FIXED
6
20W/6OHMX2
135135
24
ZONETRIGGER OUTPUTS
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED
OUTPUT
ZONE1
1234 5
L
R
1234 5
SOURCEINPUTS
The MI1 connects to the NuVo amplifier using a standard mono patch cable with a mini-plug on each end. Plug one end into the EXT. MUTE input on the back of the amplifier and the other end into the input on the front of the Mi1.
MUTE INTERFACE
ADAPTER
NV-MI1
CONNECTTO
MUTE INPUT
2
EMITTEROUTPUTS
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
ZONE6
4
6
DOORBELL 1
DOORBELL 2
Connectto Telephone RJ-11
Line1: Pins 3,4 Line 2: Pins 2,5
Model NV-MI1
MuteInterface Module
20W/6OHMX2
SUM1
SUM2
SYSON
EXT.MUTE
SYSTEM
A
B
A
B
CONNECTTO
NV-E6DEZP
USENV-NC1
CABLE
NETWORK
RS-232
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
DIGITALLINK
USECNLYWITH 250V FUSE
MODELNV-6DM
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz500W
FUSE:T5A
NuVoTechnologiesCincinnati OhioUSA
www.nuvotechnologies.com
CONFORMSTO
R
ULSTD.6500
US
C
CERTIFIEDTO
CAN/CSASTD.E60065
3033118
Essentia D
V.II
The back of the MI1 will accept up to two AC or DC voltages from two different doorbell chimes. This connection is done with a two conductor wire from the terminals on the doorbell chime to the Doorbell A or Doorbell B inputs on the back of the MI1. Polarity is not important for this connection.
15
Up to two phone lines can be brought into the RJ-11 connection on the back of the MI1. The voltage from the phone ringer will trigger the NuVo System to mute.
Page 17
XIII. NV-LSA40 Local Source Amplifier
The LSA40 is 40 watt accessary amplifier that allows any line-level audio signal local to a zone to be amplified through that zone’s speakers. It is designed to be used universally in a variety of applications, but as shown in fig. 18, it can be triggered on and off by any zone keypad. When connected to the keypad, the user will listen to the NuVo audio system when the zone is turned on. When the zone is off the LSA40 will automatically amplify any incoming local audio signal.
Fig. 18
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE1
1234 5
1234 5
ZONE2
SOURCEINPUTS
VARIABLE
6
6
OUTPUTPOWER
20W/6OHMX2
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
SOURCELINK
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE3
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
VARIABLE
OUTPUT
OUTPUTPOWER
20W/6OHMX2
OUTPUTPOWER
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE4
13
1
5
24
ZONETRIGGER OUTPUTS
Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier.
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED OUTPUT
ZONE5
OUTPUTPOWER
20W/6OHMX2
135
5
2
6
VARIABLE
OUTPUT
TIP=L RING=R
FIXED OUTPUT
ZONE6
4
EMITTEROUTPUTS
6
OUTPUTPOWER
20W/6OHMX2
SUM1
SUM2
Essentia D
SYSON
EXT.MUTE
SYSTEM
V.II
CONNECTTO NV-E6DEZP
USENV-NC1
CABLE
NETWORK
RS-232
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
DIGITALLINK
USEONLYWITH 250V FUSE
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz 500W
NuVoTechnologiesHebronKY USA
www.nuvotechnologies.com
R
US
C
CAN/CSASTD.E60065
3033118
MODELNV-6DM2
CONFORMSTO
ULSTD.6500 CERTIFIEDTO
NuVo System zone speakers.
FUSE:T5A
Atwoconductorwireisusedasavoltage trigger from the LSA40 the NuVo zone keypad. When the zone is turned on this allows to NuVo system audio to pass to the zone speakers. When the zone is turned off the internal amplifier of the LSA40 is automatically engaged.
Zone/Room1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
The connection from the LSA40 to the Essentia or Concerto keypads is done using the provide two
LSA40P Back
MODEL:NV-LSA40-DC LOCALSOURCEAMPLIFIER
+
+
Control
28VDC
Voltage
1.5A
-
-
R
T
E
E
T
K
N
I
CM
TOA
+
+
L
L
3033118
ER
M
K
-
-
L
L
A
P
E
L
P
IF
R
+
R
+
S
I E
R
T
E
E
T
K
N
I
R
TO
-
R
-
R
DESIGNEDINUSA
MADEINCHINA
LSA40P Front
INPUT
POWER
50 Watt AC power adapter supplied with the LSA40P
prong plug.
0
1
F
2
3
E
4
D
5
C
6
7
B
8
A
9
16
Page 18
XIV. NV-LSA40PD Local Source Amplifier Power Distribution Hub
The LSA40PD is a great device for distributing the necessary DC power to up to 4 individual LSA40 amplifiers. This allows the LSA40 components to be remotely located without the need for an external power supply in the zone, fig. 19. The LSA40PD is typically located where the Essentia amplifier is installed. The power from the head end to each of LSA40 locations is sent over standard 16 gauge speaker wire.
Fig. 19
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
TIP=L
FIXED
OUTPUTPOWER
20W/6OHMX2
SOURCEINPUTS
VARIABLE
OUTPUT
RING=R
OUTPUT
ZONE2
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L
FIXED
LRLRL
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE3
6
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
6
SOURCELINK
OUTPUTPOWER
20W/6OHMX2
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE4
VARIABLE
OUTPUT
RING=R
OUTPUT
ZONE1
1234 5
R
1234 5
Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier.
VARIABLE
OUTPUT
OUTPUTPOWER
OUTPUTPOWER
20W/6OHMX2
TIP=L
20W/6OHMX2
RING=R
FIXED
OUTPUT
ZONE5
135135
6
24
ZONETRIGGER OUTPUTS
2
VARIABLE OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
ZONE6
4
EMITTEROUTPUTS
6
OUTPUTPOWER
20W/6OHMX2
LSA40 Back
RS-232
Essentia D
V.II
SYSON
SUM1
CONNECTTO
NV-E6DEZP
USENV-NC1
CABLE
SUM2
EXT.MUTE
SYSTEM
NETWORK
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
DIGITALLINK
120V 60Hz500W
www.nuvotechnologies.com
C
3033118
USECNLYWITH 250V FUSE
MODELNV-6DM2 SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
CONFORMSTO
R
ULSTD.6500
US
CERTIFIEDTO
CAN/CSASTD.E60065
FUSE:T5A
MODEL:NV-LSA40
LOCALSOURCEAMPLIFIER
2
1.5A
+
8 V D
TO
C
-
TOAMPLIFIER
+
L
-
L
R
+
-
R
NuVoTechnologiesLLC Cincinnati, Ohio USA
www.nuvotechnologies.com
MadeInChina
DesignedInUSA
WIRESTRIP5/16” (8MM)
D
+
A P Y E
-
K
+
L
-
L
R
+
TOSPEAKER
-
R
LSA40 Back
MODEL:NV-LSA40
LOCALSOURCEAMPLIFIER
2
D
+
1.5A
+
8
A
V
P
D
Y
TO
C
E
-
K
-
TOAMPLIFIER
+
+
L
L
-
-
L
L
R
+
R
+
TOSPEAKER
-
R
-
R
NuVoTechnologiesLLC Cincinnati, Ohio USA
www.nuvotechnologies.com
MadeInChina
DesignedInUSA
WIRESTRIP5/16” (8MM)
16 gauge 2 conductor speaker wire is required to send voltage from the LSA40PD to four separate zones.
LSA40PD
+
-
+
-
LSA40PD Front
POWER
200 Watt AC power adapter included with the LSA40PD
Back
MODEL:NV-LSA40PD-DC LOCALSOURCEAMPLIFIER
28VDC5A
+
ZONE1
-
+
ZONE2 ZONE4
-
DESIGNEDINUSA MADEINCHINA
R
T
E
E
T
K
N
I
CM
D
3033118
ZONE3
R
T
E
E
T
K
N
I
AC Power Source
LSA40 Back
MODEL:NV-LSA40
LOCALSOURCEAMPLIFIER
2
D
+
1.5A
+
8
A
V
P
D
Y
TO
C
E
-
K
-
TOAMPLIFIER
+
+
L
L
-
-
L
L
R
+
R
+
TOSPEAKER
-
R
-
R
NuVoTechnologiesLLC Cincinnati, Ohio USA
www.nuvotechnologies.com
MadeInChina
DesignedInUSA
WIRESTRIP5/16” (8MM)
LSA40 Back
MODEL:NV-LSA40
LOCALSOURCEAMPLIFIER
2
D
+
1.5A
+
8
A
V
P
D
Y
TO
C
E
-
K
-
TOAMPLIFIER
+
+
L
L
-
-
L
L
R
+
R
+
TOSPEAKER
-
R
-
R
NuVoTechnologiesLLC Cincinnati, Ohio USA
www.nuvotechnologies.com
MadeInChina
DesignedInUSA
WIRESTRIP5/16” (8MM)
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
17
Page 19
XV. NV-LSI12 Local Source Interrupt
A lower cost alternative to the LSA40 is the LSI12. This is a non-amplified local source interrupt. It is installed in the same way the LSA40 is installed, but the incoming local signal must be amplified, fig 20. This is a useful accessory where a local amplified signal is already present.
Fig. 20
The connection from the LSI12 is
The selected zone speaker output of the Essentia or Simplese amplifier is wired directly to the LSI12.
done with the provided two prong plug. Make sure that red is positive and black is negative when splicing the two conductor wire from the LSI12.
VARIABLE
OUTPUT
OUTPUTPOWER
TIP=L RING=R
FIXED OUTPUT
ZONE1
1234 5
1234 5
SOURCEINPUTS
20W/6OHMX2
VARIABLE
ZONE2
20W/6OHMX2
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
SOURCELINK
ZONE3
VARIABLE
OUTPUT
RING=R
OUTPUT
TIP=L
FIXED
OUTPUT
OUTPUTPOWER
TIP=L
RING=R
FIXED
OUTPUT
6
6
OUTPUTPOWER
20W/6OHMX2
ZONE4
VARIABLE
OUTPUT
RING=R
OUTPUT
TIP=L
FIXED
OUTPUTPOWER
20W/6OHMX2
1
5
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE5
13
24
ZONETRIGGER OUTPUTS
OUTPUTPOWER
20W/6OHMX2
135
5
2
6
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE6
4
EMITTEROUTPUTS
6
OUTPUTPOWER
20W/6OHMX2
SUM1
SUM2
Essentia D
SYSON
EXT.MUTE
SYSTEM
V.II
CONNECTTO
NV-E6DEZP
USENV-NC1
NETWORK
RS-232
USEONLYWITH 250V FUSE
PROGRAM
CONNECTTO
NV-E6DX
USENV-SLC1
CABLE
CABLE
DIGITALLINK
MODELNV-6DM2
SIXSOURCESIXZONE
AUDIODISTRIBUTIONSYSTEM
120V 60Hz 500W
NuVoTechnologiesHebronKY USA
www.nuvotechnologies.com
CONFORMSTO
R
ULSTD.6500
CERTIFIEDTO
S
C
CAN/CSASTD.E60065
3033118
FUSE:T5A
0
1
F
2
3
E
4
D
5
C
6
7
B
8
A
9
VOLUME
MUTE
CD
TNR1
HD
TNR2
SAT2
SAT1
A two conductor wire from a relay on the LSI12 plugs into the back of the zone keypad. When the Essentia or Simplese keypad is turned off the local source is routed to the zone speakers. The Essentia or Simplese is active when the zone keypad is turned on.
LSI12 front
LOCALSOURCE
SWITCH
NV-LSI12
CONNECTTO
AMPLIFIER
LSI12 back
Model NV-LSI12
MuteInterface Module
RLY+
ToKeypad
RLY-
L­L+
plifier
R­R+
To A m
L-
L+ R­R+
ToSpeakers
Four conductor speaker wire from the LSI12 to the zone speakers.
18
Speaker input from Essentia or Simplese.
Page 20
XVI. NV-P2100 200 Watt Auxiliary Amplifier
The P2100 is specifically designed for use with the NuVo Systems' lineouts. It can be used with either the fixed or variable lineouts on the Essentia with either a 1/8” (3.5mm) to 1/8” stereo patch cable or a 1/8” stereo to RCA patch cable, Fig 21.
There are two methods for triggering the P2100 from the Essentia outputs. One is to set the POWER MODE switch on the P2100 to Audio (the extreme left position) and allow an incoming audio signal from the Essentia System to turn on the P2100. The second method is to place the POWER MODE switch in the AC/DC (extreme right) position. This will turn on the P2100 when the Essentia is on. An additional feature of Essentia is zone specific triggers that will trigger the P2100 only when that zone is turned on.
Fig. 21
NV-P2100 Amplifier
Essentia Amplifier
AUDIO
L
R
INPUT
OUTPUT
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
ZONE1
ZONE1
1234 5
1234 5
INPUT
2
OUTPUTPOWER
20W/6OHMX2
SOURCEINPUTS
SENSITIVITY
OdBV= 1.0RMS
LEFT
0
-12
+6
+6
ZONE2
ZONE2
RIGHT
0
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
-12
POWER
MODE
ON/OFFSWITCH AUDIO AC/DC
OUTPUTPOWER
6
6
CONTROL
CONTROL
20W/6OHMX2
VOLTAGE TRIGGER
3-30VOLTS ACOR DC
CONNECT TO
NV-E6DX
USE NV-SLC1
CABLE
SOURCELINK
ZONE3
ZONE3
VARIABLE
OUTPUT
TIP=L
RING=R
FIXED
OUTPUT
OUTPUTPOWER
20W/6OHMX2
Utilizing the voltage trigger requires a mono 1/8” (3.5mm) patch cable from either the System ON output on the Essentia to the P2100 Voltage trigger input, or from the specific Zone Trigger on the Essentia to the Voltage Trigger on the P2100, Fig. 22.
RS232 Interface
The RS232 port allows external two-way communication with the Essentia System. Home automation systems such as Crestron and AMX can be set up to operate Essentia. The RS232 addendum contains the necessary command sets for communication with the Essentia System.
Fig. 22
NV-P2100 Amplifier
AUDIO
INPUT
L
R
OUTPUT
INPUT
SENSITIVITY
OdBV = 1.0RMS
RIGHT
LEFT
0
2
-12
+6
+6
Essentia Amplifier
ZONE 5
2
2
1
5
45
ZONE TRIGGEROUTPUTS
3
6
ZONE 6
135
4
2
EMITTER OUTPUTS
CONTROL
CONTROL
VOLTAGE
POWER
TRIGGER
MODE
ON/OFF SWITCH
3-30 VOLTS
AC OR DC
AUDIO AC/DC
0
-12
SUM1
SUM2
6
19
Page 21
Troubleshooting
Symptom Probable Cause
Remedy
When the keypad is plugged in there is a loud pop through the speakers and the keypad does not work.
When the keypad is plugged in, it just flashes and has no functionality.
The amplifier is plugged in and turned on, but the STAND BY LED is not lit and none of
The zone is on and music is playing, but the keypad only flashes when I try to change source, control volume, mute, or turn the zone off.
Improperly wired CAT5 cable. Check that you are using the 568A or B
wiring standard (see section I: Crimping CAT5 wire). The best way to know is to use a CAT5 tester.
Assigning duplicate addresses to multiple keypads.
This is most likely caused by a blown fuse on the power supply.
The parental lock is assigned on that particular keypad.
Each keypad must have a unique address set with the Zone Address rotary switch located on the back of the keypad (see section VII, Installing the Essentia keypads.
The fuse is accessed at the back of the amplifier where the AC cord plugs in. It requires a 4 amp time delay fuse.
Pressing and holding the active Source button on the keypad will activate a lock feature and prevent any functionality. When locked the keypad will simply flash when a function is attempted. Pressing and holding the source button again will unlock the keypad.
All the keypads change when a source is selected on only one.
With the keypads plugged in, the POWER LED on the front of the amplifier will not turn on.
The IR repeater does not properly control the audio source equipment.
The keypads are set for Source Grouping. Pressing the MUTE and Source 3 button
simultaneously sets the Source Grouping feature. This will cause multiple keypads to always share the same source (see Section IX, Zone EQ and Source Grouping on page 11).
One or more improperly wired CAT5 cables. Make sure the amplifier is turned on. Test
that the POWER LED on the amplifier turns on when the Network Cable is unplugged. Next, unplug all the CAT5 cables from the EZ Port and plug them back in one at a time until the bad cable(s) is discovered.
One or more of the IR emitters are not properly placed over the IR receiver on the audio source equipment, or the IR output on the Essentia does not correspond with the audio equipment you are controlling.
20
Reposition the LED end of the emitter on the face of the source equipment, so it is flashing directly over that source’s IR receiver. Make sure that the emitter plugged into IR Output #1 is actually going to source #1 , and so on for sources 2-6.
Page 22
Specifications
Zones 1-6 Power Amplifier Outputs Zone Trigger Outputs
Continuous Average Output Power 40W (20W x 2) Output Power 12V @ 50mA Two channels driven 30-20kHz @1% THD Outputs 6 (zones 1-6) Rated Distortion (1/2 power) 0.40% Rated Impedance 6 Ohms Power Requirements Damping Factor 50+ Power Supply 120VAC/240VAC 50/60Hz Frequency Response (20-20kHz)
Zones 1-6 Preamplifier Outputs Cower Consumption average 50VA (40W) Variable output 0-600mV operating conditions Fixed output 600mV Power Consumption no signal 30VA (12.5W) Impedance 600 Ohms USA Safety Listing (UL 6500)
Source Inputs 1-6 CE Listing/SEMKO (EN60065, EN55013, input Impedance 10K EN55020, EN6100-3-2, EN6100-3-3/A1) Input Sensitivity for rated power 300mV RMS Input Overload 3V RMS Physical Specifications
Emitter Outputs Unit Size Inches 3 1/2 H x 17 W x 12 3/4 D Source Outputs 6 Shipping Size Millimeters 290 x 540 x 440 Sum Outputs 2 Shipping Size Inches 11 3/8 x 21 1/4 x 17 3/8 Output Drive Current 100mA Unit Weight Kilograms 7.8 Output Drive Voltage 12V Unit Weight Pounds 17.0 Compatible with single and dual emitters Shipping Weight Kilograms 12.7
System Keypad Size Millimeters 107.2 H x 41.5 W x 32.5 D System On 12V @ 50mA Keypad Size Inches 4 1/4 H x 1 5/8 W x 1 1/4 D External Mute 3-12V DC
±2 dB
Power Consumption all channels 340VA (290W) driven to full-rated power
Canada Safety Listing (CAN/CSA E60065.00)
Unit Size Millimeters 88 H x 430 W x 325 D
Shipping Weight Pounds 28.0
NuVo reserves the right to change specifications without notice.
21
Page 23
Addendum
Control Interface Description Document for the Nuvo E6D Main Unit
Revision E (for Nuvo E6D Mark II systems only) June 8, 2006
DB9M PORT PINOUTS:
SERIAL PORT PARAMETERS: protocol.
RULES OF PROTOCOL:
(1) For alpha ASCII characters, always use UPPER CASE. In this document, actual characters in a string are presented in
BOLD type. (2) All numerical fields are coded as ASCII digit characters. (3) Each Command string is STARTED with an ASCII “ ” character and terminated by a <CR> character (0D hexadecimal).
Each response string issued by the E6D will START with an ASCII “ ” and be terminated with a <CR> character (0D
hexadecimal). (4) If a command has an error in it (does not adhere to exact command syntax), the E6D will respond with a “
string. (5) Whenever queuing multiple commands to the E6D, the host program should pause for 50 milliseconds between
commands to prevent buffer overruns.
NUVO POWER-ON STATE:
(1) Each zone is OFF until ON command is received.
(2) Each zone's ZoneSet status will be as set by the special key combination settings as detailed in the owner's manual.
If no keypad is connected with a given zone address, then ZoneSet will default to:
A. OR0 (No override) B. BASS+0 (Bass FLAT) C. TREB+0 (Treble FLAT) D. GRP0 (SOURCE GROUPING OFF) E. VRST1 (VOLUME RESET TO 50 dB ON)
If these zone settings are overridden by the commands which follow in this document, the overridden values will reset to the default values above upon cycling power on the Main Unit.
(3) For the first four seconds after power-on, a series of non-control related characters will be issued at a wide range of
baud rates. These are necessary queries to a program that may be running on a connected PC for the purpose of Firmware field upgrades. They should be ignored by the host control system.
Nuvo Transmit to System Controller on pin 2. Nuvo Receive from System Controller on pin 3. Ground on pin 5.
RS232, RTS/CTS or software flow control (XON/XOFF) NOT required, 9600 baud, 8N1
*
#
#?<CR>”
NON-VOLATILE COMMANDS AND ASSOCIATED RESPONSES IR carrier frequency, the effect of all commands is non-permanent; i.e. when power is cycled on the main unit, it will return to default values. The commands that are an exception to this rule follow in this section.
********************************************************************************* COMMAND: Reads status of SOURCE IR carrier frequency settings. RESPONSE: where:
*IRSETSR<CR> #IRSET:aa,bb,cc,dd,ee,ff<CR>
aa = IR carrier frequency of SOURCE 1 ("38" or "56")
bb = carrier frequency of SOURCE 2 ("38" or "56") cc = carrier frequency of SOURCE 3 ("38" or "56") dd = carrier frequency of SOURCE 4 ("38" or "56") ee = carrier frequency of SOURCE 5 ("38" or "56") ff = carrier frequency of SOURCE 6 ("38" or "56")
With the exception of commands associated with setting the
22
Page 24
NOTE: the Main Unit ships with the carrier frequency DEFAULT setting of 38 KHz for all six sources.
********************************************************************************* COMMAND: Restores DEFAULT SOURCE IR carrier frequency settings (38 KHz for all six sources). RESPONSE: Same response as for
********************************************************************************* COMMAND: - sets SOURCE x to 56 KHz IR repeat carrier (x is 1 to 6). RESPONSE: Same response as for
********************************************************************************* COMMAND: - sets SOURCE x to 38 KHz IR repeat carrier (x is 1 to 6). RESPONSE: Same response as for
*********************************************************************************
COMMAND/RESPONSE DESCRIPTIONS. NOTE zone number field xx should ALWAYS include a lead zero (“0”) for zone numbers less than 10.
*IRSETDF<CR>
#IRSETSR<CR>
*SxIR56SET<CR>
#IRSETSR<CR>
*SxIR38SET<CR>
#IRSETSR<CR>
COMMAND: * - Connect STATUS REQUEST where xx is zone # from 1 to
RESPONSE: # -ppp = “ON” (2 characters)
The remaining fields are not included in the response if ppp is “OFF”:
This response will also be issued in response to pressing the ON/OFF, VOLUME, or SOURCE keys on a KEYPAD. NOTE the response will be issued if a SOURCE key is pressed on a zone that is powered OFF even though the key press has no effect on the system. It will be output at every increment during a volume ramp initiated by HOLDING a VOLUME UP or VOLUME DOWN key on a keypad. It will also be issued at every increment of a volume ramp commanded by the and commands (see below).
ZxxCONSR<CR>
12.
ZxxPWRppp,SRCs,GRPt,VOL-yy,Pzzz<CR>
or “OFF” (3 characters)
-s = SOURCE NUMBER 1 to 6
-q=0ifSOURCE GROUP is ON 1if SOURCE GROUP is OFF
-yy = level below max in dB: -00 to -78 dB (include lead 0 for all single-digit values)
-yy = “MT” if in MUTE state
-yy = “XM” if external MUTE is being held
active
-zzz = “MST” if this zone is PARTY MASTER
-zzz = “SLV” if this zone is SLAVED to a PARTY MASTER in another zone
-zzz = “OFF” if this zone is under LOCAL CONTROL only (either there is no party master, or this zone has been manually overridden)
*ZxxVOL+<CR> *ZxxVOL-<CR>
The MUTE value will be asserted if a * command has been received, OR if the volume is run all the way to the lowest possible point (volume off). An active EXTERNAL
ZxMTON<CR>
23
Page 25
MUTE input, however, will always override other volume response values with the “XM” response.
********************************************************************************* COMMAND: * ZoneSet STATUS REQUEST where xx is zone # from 1 to 12. RESPONSE: # -p=1ifatleast one of the permanent
ZxxSETSR<CR>
ZxxORp,BASSyy,TREByy,GRPq,VRSTu
values have been overridden* by an RS232 command.
-yy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments if
set by RS232, -8, -6,-4, 0, +4, +6, +8 if set on keypad.
-q=0ifSOURCE GROUP is ON
1 if SOURCE GROUP is OFF
-u=0ifVOLUME RESET is ON
1 if VOLUME RESET is OFF
*override set to 1 FOR THIS ZONE only if one of commands * , * , or * are issued (see descriptions below).
ZxxGRPq<CR>
Once a parameter has been SET by one of these commands, it will remain UNTIL: a. power is cycled on the Main Unit either with the front panel power switch or by removing AC power. Upon power-up,
the system will restore keypad permanent settings (see the User Manual for details on how to perform these settings).
b. an operator manually sets one of these parameters from a keypad. This takes the unit out of OVERRIDE state, but
other RS232-commanded settings will remain until another RS232 command overrides them, or power is cycled.
This response is also issued whenever these parameters are set from a keypad.
********************************************************************************* COMMAND: * Turn zone xx ON. RESPONSE: Same response as for
********************************************************************************* COMMAND: * Turn zone xx OFF. RESPONSE: Same response as for
********************************************************************************* COMMAND: * Turn ALL zones OFF. RESPONSE: #
This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.
ZxxON<CR>
*ZxxCONSR<CR>
ZxxOFF<CR>
*ZxxCONSR<CR>
ALLOFF<CR>
ALLOFF<CR>
ZxxBASSyy<CR> ZxxTREByy<CR>
********************************************************************************* COMMAND: * Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps. RESPONSE: #
The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an Command is received. Note that to stop the ramp with this command before maximum volume, one reference zone must be periodically polled with a
*ZxxCONSR<CR>
ALLV+<CR>
ALLV+<CR>
*ALLHLD<CR>
24
Page 26
Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.
********************************************************************************* COMMAND: * Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps. RESPONSE: #
ALLV-<CR>
ALLV-<CR>
The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an Command is received. Note that to stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.
********************************************************************************* COMMAND: * Stops ramp action initiated by Or RESPONSE: #
This results in a HOLD of the level at time of command receipt.
********************************************************************************* COMMAND: * ALL MUTE ON. RESPONSE: #
********************************************************************************* COMMAND: * ALL MUTE OFF. RESPONSE: #
******************************************************************************** COMMAND: * Switch zone xx to SOURCEp(1to6). RESPONSE: Same response as for
********************************************************************************* COMMAND: * Set volume of zone xx to level yy below max in dB from 0 to 78 dB (include lead 0 for all
RESPONSE: Same response as for
*ZxxCONSR<CR>
ALLHLD<CR> *ALLV+<CR> *ALLV-<CR>
ALLHLD-<CR>
ALLMON<CR>
ALLMON<CR>
ALLMOFF<CR>
ALLMOFF<CR>
ZxxSRCp<CR>
*ZxxCONSR<CR>
ZxxVOLyy<CR>
single-digit values).
*ZxxCONSR<CR>
*ALLHLD<CR>
********************************************************************************* COMMAND: * STARTS zone xx volume ramp UP at the rate of +10 dB per second in +1 dB steps. (This is
RESPONSE: Same response as for
********************************************************************************* COMMAND: * STARTS zone xx volume ramp DOWN at the rate of -10 dB per second in -1 dB steps. (This
RESPONSE:
********************************************************************************* COMMAND: * STOPS zone xx volume ramp initiated by or commands.
RESPONSE: #
********************************************************************************* COMMAND: * zone xx MUTE ON (mutes currently connected source) RESPONSE:
ZxxVOL+<CR>
the same as holding VOLUME UP key on a KEYPAD for 1 second).
*ZxxCONSR<CR>, updated 10 times per second.
ZxxVOL-<CR>
is the same as holding VOLUME UP key on a KEYPAD for 1 second).
Same response as for *ZxxCONSR<CR>, updated 10 times per second.
ZxxVHLD<CR> *ZxxVOL++<CR> *ZxxVOL--<CR>
This results in a HOLD of the level at time of command receipt.
ZxxVHLD<CR>
ZxxMTON<CR>
Same response as for *ZxxCONSR<CR>
25
Page 27
********************************************************************************* COMMAND: * zone xx MUTE OFF (returns zone output to currently connected source at previous volume
RESPONSE:
********************************************************************************* COMMAND: * zone xx BASS EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.
RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile BASS setting (set from keypad) for this zone until power is cycled.
********************************************************************************* COMMAND: * zone xx TREBLE EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.
RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile TREBLE setting (set from keypad) for this zone until power is cycled.
********************************************************************************* COMMAND: * zone xx SOURCE GROUP ON. RESPONSE:
NOTE: sending this command to the E6D will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.
ZxxMTOFF<CR>
setting).
Same response as for *ZxxCONSR<CR>
ZxxBASSyyy<CR>
USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.
Same response as for *ZxxSETSR<CR>
ZxxTREByyy<CR>
USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.
Same response as for *ZxxSETSR<CR>
ZxxGRPON<CR>
Same response as for *ZxxSETSR<CR>
********************************************************************************* COMMAND: * zone xx SOURCE GROUP OFF. RESPONSE:
NOTE: sending this command to the will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.
********************************************************************************* COMMAND: * zone xx VOLUME RESET ON. RESPONSE:
NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.
********************************************************************************* COMMAND: * zone xx VOLUME RESET OFF. RESPONSE:
NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.
********************************************************************************* COMMAND: * zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone. This is
RESPONSE: #
ZxxGRPOFF<CR>
Same response as for *ZxxSETSR<CR>
ZxxVRSTON<CR>
Same response as for *ZxxSETSR<CR>
ZxxVRSTOFF<CR>
Same response as for *ZxxSETSR<CR>
ZxxLKON<CR>
the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).
ZxxLKON<CR>6
26
Page 28
*********************************************************************************
COMMAND: * zone xx KEYPAD LOCK ON This will RESTORE ALL keypad control input on the zone
RESPONSE: #
********************************************************************************* COMMAND: * Firmware version query.
RESPONSE: # where x is the major version number and yy is the minor version number.
********************************************************************************* RESPONSE: # Issued whenever the External MUTE first activates (closure to ground) and 0 whenever the
NOTE: there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.
********************************************************************************* RESPONSE: # Issued whenever External MUTE de-activates (open connection to ground).
NOTE: there is no COMMAND associated with this response; it is always initiated by a change at the EXT. MUTE input.
ZxxLKOFF<CR>
(useful as Parental lock control) . This is the same as deactivating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).
ZxxLKOFF<CR>
VER<CR>
NUVO_E6D_vx.yy<CR>
EXTMON<CR>
External MUTE de-activates (open connection to ground).
EXTMOFF<CR>
27
Page 29
ESS513 0706
Loading...