NuTone EC50, 696NC, EC70, 695C, VSBP50M Installation Instructions Manual

INSTALLATION INSTRUCTIONS
ECONOMY VENTILATION FAN
MODELS: EC50 & EC70, 696NC & 695C, VSBP50M
HOUSING INSTALLATION
Rough Opening: 8¼” long x 7¼” wide Housing Size: 7
3
16” x 81⁄16” x 37⁄8
Refer to Figure 1A. Remove motor plate from housing before mounting. Insert screwdriver between motor plate and side of housing with duct collar. Gently pry the housing away from the motor plate while pulling up on the motor plate to disengage the plate from the housing.
1. With nails or screw, secure (but do not tighten) the housing to the ceiling or wall through the two keyhole slots in the mounting tabs.
NOTE: Prior to completely tightening, adjust the housing so
that the outer edge will remain 1/8” to 1/4” recessed from the finished ceiling or wall. For the grille to fit properly, the housing must not extend outside the finished wall surface.
2. Secure discharge adapter over flange on housing and connect ducting to discharge, make sure housing is securely mounted to prevent fan from vibrating and causing noise.
WIRING
IMPORTANT: Ensure all wiring complies with local codes and the
unit is properly grounded.
1. Refer to Figure 2. Run power leads from the wall or timer switch to the unit.
2. Using approved wire connectors, connect supply wires to fan wires: BLACK to BLACK and WHITE to WHITE. Connect ground wire (GREEN to bare) to the GREEN ground screw in the fan’s junction box.
30040605C
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire and electric shock, do not use this
fan with any solid-state speed control device.
8. Suitable for use over a tub or shower when connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive
installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.
11. When performing installation, servicing or cleaning the unit, it is
recommended to wear safety glasses and gloves.
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Do not mount this product in a ceiling insulated to a value
greater than R40. This product is designed to be mounted in a ceiling or in a standard 2” x 4” wall.
3. Do not use this product in kitchens.
4. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
5. Please read specification label on product for further
information and requirements.
READ AND SAVE THESE INSTRUCTIONS
!
CAUTION
SECURE
FAN TO
HOUSING
PLUG INSERTS INTO HOUSING’S RECEPTACLE
TABS
SLOTS
FIGURE 1
FIGURE 1A
MOUNTING TABS (TYP.)
FIGURE 2
REGISTER YOUR PRODUCT ONLINE AT
• For Broan EC50 or EC70: www.broan.ca
• For NuTone 696NC or 695C: www.nutone.ca
BLACK WHITE
BE0009A
SWITCH BOX
WHITEBLACK
120 V AC, 60 Hz HOUSE POWER
FAN
HOUSING
One Year Limited Warranty
Broan-NuTone Canada warrants to the original consumer purchaser of its products that such products will be free from defects in materials and workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone Canada or an authorized representative), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER'S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary by jurisdiction. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or telephone number below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Date of Installation Builder or Installer
Model No. and Product Description
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest Broan-NuTone Canada Incorporated dealer
Dial Free 1-888-882-7626
Please be prepared to provide:
Product model number • Date and Proof of Purchase • The nature of the difficulty
Broan-NuTone Canada Incorporated
1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9
www.broan.ca
www.nutone.ca
FIGURE 3
DUCTING
1. Refer to Figures 3 and 4. Run 3” round duct from the discharge
opening to the outside of the house.
INSTALLING THE FAN AND GRILLE
1. Refer to Figure 1. Insert the tabs into the housing’s slots.
2. Push the fan into the housing until it is secure against the electrical box.
3. As illustrated, tighten the screw and insert the plug into the housing’s receptacle. IMPORTANT: Ensure the blower wheel turns freely.
4. The grille may be installed when the finished walls have been completed. Place the grille’s spring mounting clips into the fan unit. Install the clips on both sides.
FIGURE 4
HORIZONTAL AND FROM HORIZONTAL TO VERTICAL DISCHARGE
FAN IN
BH0037A
VERTICAL AND FROM VERTICAL TO HORIZONTAL DISCHARGE
CEILING
3” ROUND DUCT
ROOF CAP
90° ELBOW
WALL CAP
3” ROUND DUCT
ROOF CAP
90° ELBOW & WALL CAP ASSEMBLY
FAN
IN WALL
BH0038A