NuTone ULTRA SILENT QTRN, ULTRA SILENT QTREN110, ULTRA SILENT QTREN, ULTRA SILENT QTREN080, ULTRA SILENT QTRN050F Instructions Manual

QTRN / QTREN SERIES ULTRA SILENTTM FANS
READ AND SAVE THESE INSTRUCTIONS
MODELS QTREN080 • QTREN110
Page 1
To register this
product visit:
www.nutone.com
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN­JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip­ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori­ties.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard­ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further informa­tion and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear­ance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Use of speed controls other than the NuTone Models 78V and 78W may cause a motor humming noise.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO­RIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to mis­use, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN­NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EX­CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.nutone.com 888-336-3948
Installer: Leave this manual with the homeowner.
TYPICAL INSTALLATIONS
Housing mount­ed to I-joists.
Housing mount­ed anywhere between I-joists using hanger bars.
MODELS QTREN080 • QTREN110
Housing mount­ed anywhere between trusses using hanger bars.
PLAN THE INSTALLATION
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
Page 2
Housing mount­ed to joists.
Housing mount­ed anywhere between joists using hanger bars.
Housing mount­ed anywhere between truss­es using hanger bars.
NOT FOR USE IN
A COOKING AREA.
INSULATION*
(Place around and
over Fan Housing.)
FAN
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
4-IN. ROUND
DUCT*
*Purchase separately.
Seal duct joints with
tape.
Cooking
Equipment
4-IN.
ROUND
ELBOWS*
Floor
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
OR
WALL CAP*
(with built-in
damper)
The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Plan to supply the unit with proper line voltage and appropriate power cable.
INSTALL HOUSING & DUCT
MODELS QTREN080 • QTREN110
Page 3
1a. Mount
housing to joist or I-joist.
Use a pliers to bend housing TABS out
0
. Hold housing
to 90 in place so that the housing tabs contact the bottom of the joist. The housing mounts with four (4) screws or nails. Screw or nail housing to joist through lowest holes in each mounting flange, then through highest holes. NOTE: Mounting to I-JOIST (shown) requires use of SPACERS (included) between the highest hole of each mounting flange and the I-joist.
TABS
SPACER
(use for mounting to I-Joist)
OR
I-JOIST
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
NAIL (4)
Extend HANGER BARS to the width of the framing. Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
To ensure a noise-free mount: Secure hanger bars together
*
with SCREWS or use a pliers to crimp mounting channels tightly around hanger bars.
SCREW (2)
*
BOTTOM EDGE
OF FRAMING
1b. Mount housing anywhere between
trusses, joists, or I-joists using hanger bars.
Sliding hanger bars are provided to allow for accurate posi­tioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24”.
TAB
SCREWS (4)
STD
HANGER
BAR (4)
Attach the MOUNTING CHANNELS to the housing using the SCREWS supplied. Make sure TABS face “up” as shown. Use the set of channel mounting holes (marked “STD”) to mount the housing flush with the bottom of the drywall. Use the other set of holes (not marked) to mount the housing flush with the top of the drywall.
MOUNTING
CHANNEL (2)
2. Attach damper/duct connector.
Snap damper / duct connector onto housing. Make sure con­nector is flush with top of housing and damper flap falls closed.
3. Install 4-inch round duct­work.
Connect 4-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork con­nections to make them secure and air tight.