TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. This unit must be grounded.
7. Do not connect this product as a load on a fan speed
control or light dimmer.
8. Read and understand entire instructions before proceeding
with installation.
INSTALLATION
Install controls and wire them as shown. Use following
guidelines:
• IMPORTANT:
QTXE080 Ultra Silent™ fan must be wired to SMSC080
SmartSense® control.
QTXE110 Ultra Silent™ fan must be wired to SMSC110
SmartSense® control.
• Use minimum 75 °C rated electrical wiring.
• Except for required neutral wire, these controls install
like normal switches. Make sure electrician knows each
control location must have a neutral wire. Neutral wire
at switch locations may be code requirement or regular
practice in installation municipality; but unless explicitly
specified, electrician might not install it.
• Specify deep device electrical boxes where controls will
be installed. These controls fit in most North American
electrical boxes; however, deep boxes provide extra
working space which eases installation. Labor cost
savings can offset higher box costs, which is usually
less than a dollar over standard depth boxes. Use boxes
that have 18 cu. in. minimum volume and are at least
1-1/2 in. deep.
•
All controls must be grounded using attached ground wire.
CONTROL OPERATION
MODELS SSQTXE080 • SSQTXE110
Page 2
HOW SYSTEM WORKS
Broan SmartSense® system is design to provide recommended
ventilation for desirable indoor air quality. Related ventilation
requirements of *ANSI/ASHRAE Standard 62, “Ventilation
for Acceptable Indoor Air Quality” are fulfilled when this
system is installed accordingly. Ventilation level, which is
based on home square footage and number of bedrooms,
is easily set during installation. Power outages do not
affect settings, since they are stored in power independent
(nonvolatile) memory. Energy usage is optimized by
monitoring fan on-time and adjusting automatic ventilation
as needed. Indoor air quality is provided 24-hours a day,
7-days a week.
A single Broan SmartSense® system is powerful enough
to fulfill ventilation rates for larger homes; however, it is
recommended to use multiple installations for homes with
multiple bathrooms. Multiple installations provide distributed
ventilation throughout the home. Multiple installations are
linked and communicate through home’s normal power
circuits to form an indoor air quality network.
Broan SmartSense® controls are designed and factory set for
multiple installation homes. If a single Broan SmartSense®
system is installed then System Level must be adjusted
accordingly; otherwise, fan may run continuously.
Additional features, which are turned off at factory, include
Vacation and Disabled modes. Vacation mode temporarily
disables system until Master fan is manually turned on.
Disabled mode removes system from automatic ventilation
usage. Disabled mode does not affect manual operation.
* American National Standards Institute / American Society of Heating,
Refrigerating and Air-Conditioning Engineers
HOW LED WORKS
LED works differently in Run and Program modes.
Run Mode: LED is off when fan is off. LED is on when fan
is on manual ventilation; turned on by pressing ON paddle.
LED turns on briefly every second (fast-blink) when fan is
on automatic ventilation; turned on by Broan SmartSense®
system.
Program Mode: LED is on while SET button is pressed. LED
turns on and off every second (slow-blink) when system is in
Program mode.
INDOOR AIR QUALITY NETWORK
A single Broan SmartSense® system is powerful enough
to fulfill ventilation rates for larger homes; however, it is
recommended to use multiple installations for homes with
multiple bathrooms. Multiple installations provide distributed
ventilation throughout the home.
Multiple installations communicate through a home’s
electrical power circuits to form an indoor air quality network.
Communication pathways are called links. A phase coupler
is required if multiple installations are connected to both
electrical power phases.
Individual systems in a multiple installation home can
operate independently; although, it is recommended to link
multiple installations as an indoor air quality network. If a
single Broan SmartSense® system is installed or independent
system operation is desired, proceed with “How To Set System
Level” section. If System Level is not adjusted, fan may not shut
off automatically or run unnecessarily too long.
One Broan SmartSense® control is selected as system Master
during set up. Any control can be selected as system Master,
but typically master bathroom control is chosen. All controls
are factory set as system Masters.
SmartSense® controls that are linked to Master control are
called Slaves. One Master control can link up to 10 Broan
SmartSense® Slave controls.
HOW TO LINK SMARTSENSE® SYSTEM
1. Unless another control is designated and clearly marked
on frame, under decorative plate, or documented on this
instruction sheet as Master control, go to master bathroom
control.
2. Put Master control in Program mode; press and hold SET
button for 3-seconds and then release it.
Note: Master control will automatically exit Program mode
after 4-minutes.
3. LED should be turning on and off every second (slow-blink);
if it isn’t then repeat step 2.
4. Go to first control to link as a Slave.
5. Press and hold SET button until fan turns on. If fan doesn’t
turn on in less than 5-seconds, make sure Master is in
Program mode; which is indicated with LED slow-blink.
Note: At same time Slave turns on, Master fan turns on.
Master fan should turn off automatically in less than
15-seconds.
6. Release Slave’s SET button.
7. If Master control has not automatically turned Slave off
then press Slave’s OFF paddle to manually turn it off.
8. If there are more Slave installations then go back to
Master control and repeat steps 2 through 8.
Note: Master control will automatically exit Program
mode 4-minutes after it is started. Slave link needs to be
made before Master automatically exits Program mode
or Master control’s Program mode needs to be started
again.
MODELS SSQTXE080 • SSQTXE110
Push to
turn ON
Push to
turn OFF
SmartSense
®
®
Page 3
HOW TO SET SYSTEM LEVEL
Installer, homeowner, or building science expert may adjust
Broan SmartSense® ventilation system level.
Initial Setting of System Level
1. System Level is only set in Master control. If home has
more than one installation then locate Master control;
it is usually in master bathroom or it should be clearly
marked on frame, under decorative plate, or documented
on this instruction sheet.
2. Circle, mark or highlight System Level in Table A using
home’s square footage and number of bedrooms.
Note: Building science experts may calculate different
rate based on air infiltration measurements.
3. Circle, mark or highlight same System Level in Table B.
4. If home’s System Level is 90 then next steps are not
necessary, since control’s System Level is set at factory
to 90.
5. Put Master control in Program mode; press and hold SET
button for 3-seconds and then release it.
6. LED should be turning on and off every second (slow-blink);
if it is not then repeat step 5.
7. Tap (press and release) ON or OFF paddle number of
times from Table B.
8. Exit Program mode; press and release SET button twice.
LED should turn off.
Changing System Level
1. Put Master control in Program mode; press and hold SET
button for 3-seconds and then release it.
2. LED should be turning on and off every second (slow-blink);
if it isn’t then repeat step 1.
3. Press Master control’s paddle ON once and OFF once;
System Level is changed back to factory setting of 90.
4. Tap (press and release) ON or OFF paddle number of
times from Table B.
5. Exit Program mode; press and release SET button twice.
LED should turn off.
FEATURE SELECTIONS
Vacation Mode: Used only with Master control. Temporarily
disables Broan SmartSense® system. Master control will not
automatically turn on its fan or any other system fan. After
Program mode exit, Vacation mode is cancelled when Master
control ON paddle is pressed.
Disabled Mode: When Master control is put in Disabled
mode, it will not turn on any fans for automatic ventilation
and recommended indoor air quality ventilation level is not
assured. Manual control fan operation is not affected.
Vacation Mode
1. Put Master control in Program mode; press and hold SET
button for 3-seconds and then release it.
2. LED should be turning on and off every second (slow-blink);
if it is not then repeat step 1.
3. Press Master control’s ON paddle seven times.
LED should turn off and fan turn on. After 1 to 2-seconds
fan turns off.
Vacation mode is maintained after power loss. Vacation mode
is cancelled when Master control’s paddle is pressed ON and
then OFF; System will then resume automatic operation.
Disabled Mode
1. Put Master control in Program mode; press and hold SET
button for 3-seconds and then release it.
2. LED should be turning on and off every second (slow-blink);
if it is not then repeat step 1.
3. Press Master control’s OFF paddle seven times.
4. Exit Program mode; press and release SET button twice.
LED should turn off.
Disabled mode indefinitely keeps Broan SmartSense®
system from turning fan(s) on automatically to provide
recommended ventilation for desirable indoor air quality.
Disabled mode is maintained after power loss. Disabled
mode is cancelled when Master control System Level is reset
following instructions in section “Changing System Level.”