NuTone RL6200-H, RL6100-H, RL6300-H User Manual

READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
Range Hoods
RL-H SERIES (RL6100-H, RL6200-H, RL6300-H)
IMPORTANT SAFETY INSTRUCTIONS
WARNING — TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW­ING:
• Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent from being switched on accidentally.
When the service disconnecting means cannot be locked, se­curely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
this range hood with an additional speed control device.
WARNING — TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
• Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
• Always turn hood ON when cooking at high heat or when cook­ing flaming foods.
• Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
• Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING — TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
• SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
• NEVER PICK UP A FLAMING PAN — you may be burned.
• DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.
• Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you al-
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety Tips” published by NFPA.
5” ROUND DUCT
To reduce the risk of fire or electric shock, do not use
ready know how to operate it.
ROOF CAP
ADJUSTABLE ELBOW (if needed)
ROOF
INSTALLATION INSTRUCTIONS
WARNING — TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW­ING:
• Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards
- including fire-rated construction.
• Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Con­ditioning Engineers (ASHRAE), and local code authorities.
• When cutting or drilling into wall or ceiling, do not damage elec­trical wiring and other hidden utilities.
• Ducted fans must always be vented to the outdoors.
WARNING: “To reduce the risk of fire, use only metal ductwork”. CAUTION: To reduce the risk of fire and to properly exhaust air, be
sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
PLANNING
• Recommended mounting height is 24” to 30” above the cooking surface.
• The hood should be mounted to the bottom of a standard wall cabinet. If the hood must be mounted directly to a wall, secure the hood to wall studs.
• All wiring must be properly grounded. Connection should be made to a 110-120VAC lighting circuit (15 Amp) in the circuit breaker or fuse box.
DUCTING: (a) RL6300-H installs with 7” round duct vented vertically.
RL5300-H installs with 5” round vented vertically. RL6100-H installs with 3¼” x 10” duct vented vertically or horizontally.
(b) Make the duct run as short as possible. Try to avoid the use
of elbows in the duct. All joints should be properly sealed. Do not use duct smaller than the discharge on the hood.
(c) Do not terminate duct in an attic space. Run duct to the out-
side, using a roof or wall cap to terminate the run.
5” ROUND
RL5300-H SERIES
VERTICAL OR HORIZONTAL
DISCHARGE
USING 5” DUCT
RANGE
HOOD
FIGURE 1
RL6100-H SERIES
VERTICAL OR HORIZONTAL
DISCHARGE
USING 3¼” X 10” DUCT
3¼” X 10”
FIGURE 2
RL6300-H SERIES
VERTICAL OR HORIZONTAL
DISCHARGE
USING 7” DUCT
7” ROUND
FIGURE 3