NuTone CI370 User Manual

CENTRAL CLEANING SYSTEM
Indicating Inlets
MODELS: CI370 Series
USE ONLY WITH CV653, CV750 & CV850 POWER UNITS
Mounting Bracket
MODEL: 361
INSTALLATION
2. To locate bracket on wall stud, measure approximately 18" up from finished floor level. (Height location may vary according to individual preference.)
3. Refer to Figure 1. Nail bracket to side of stud so that front edge of bracket is flush to front of stud. (The bracket may also be nailed to the front edge of the stud. For front stud mounting, use locating tabs on bracket for proper alignment.)
4. Refer to Figure 2. Remove cardboard from plaster guard frame. Using four (4) provided screws, attach the appropriate flanged fitting and inlet seal to back of inlet.
5. Replace cardboard into plaster guard frame.
6. Plumb tubing to inlet. Run 2-conductor (376 or 376UL) low voltage cable between inlet and power unit.
CAUTION: When tubing is run through the wall stud, sole plate, headers – or anywhere that building materials will be attached – place a nail plate (Model 378) over that area (on both sides if necessary) to prevent nails from piercing tubing.
WALL INLET INSTALLATION
1. Once the walls have been finished, install the wall inlets.
2. Remove the cardboard plaster guard.
3. Refer to Figure 3. For some dry wall or panel construction, the plaster frame will extend beyond the finished wall. In this case, remove plaster frame from mounting bracket by removing mounting screws.
NOTE: When using the Model 361 inlet bracket on walls thinner than 1⁄2", use a 1⁄4" spacer (not furnished) between the wall and the inlet bracket. See Figure 3A.
Spacer may be made from plywood, Masonite™, etc. Contact cement may be used to hold spacer in place during assembly. Configuration of spacer may vary depending upon installation.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
FIGURE 1
FIGURE 2
MODEL 361
SIDE
MOUNTING
FACE
MOUNTING
FIGURE 3
21/4"
31/4"
1
/4"
INLET MOUNTING
BRACKET
SPACER
WALL LESS THAN
1
/2" THICK.
PLASTER
GUARD
HOLE
FIGURE 3A
3
2
/8"
113/16"
Product specifications subject to change without notice.
4820 Red Bank Road, Cincinnati, Ohio 45227 • 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9
Printed in U.S.A., Rev. 4/01, Part No. 88384
FIGURE 5
FIGURE 6
FIGURE 7
MODEL 365C
DOUBLE FLANGED
TEE
WALL INLET
MOUNTING
BRACKET
CUT OFF APPROX.
3
4” OF WALL INLET
TUBE
WALL
361 MOUNTING BRACKET
WALL INLET
FLANGE FITTING
PLASTER FRAME
29⁄16
INLET SEAL
31⁄16
FINAL SYSTEM CHECK
Be sure all inlets are closed and soil bag is in place. Check switch on power
unit for manual on/off operation.
Check each wall inlet to be sure contacts activate indicator light and power unit when hose is inserted. A short piece of wire can be used to short contacts in wall inlet together to activate power unit. Check each wall inlet and tubing connection for air leaks. Check power unit for leaks around inlet tube and dirt receptacle.
Note:
If indicator light is RED when the hose is inserted, reverse the wiring of the 2-conductor cable at the CI370 inlet (see fig 4).
For a hose that has an ON/OFF switch on the hose, the light on the inlet will be activated only when the hose is switched “ON”.
FIGURE 4
4. Refer to Figure 4. Connect the red striped wire of the
2-conductor low voltage cable to the unused terminal screw on the inlet. Connect the remaining wire to the black pig tail wire. Cap off both wires using wire nut (supplied).
NOTE: The LED indicator light used in the CI370 is polarity sensitive. If the 2-conductor cable used to connect the inlet to the power unit does not have a polarity marking and the CI370 is wired backwards, no damage will result; however, the indicator will light RED instead of GREEN when the hose is inserted into the inlet. To correct this condition, simply reverse the 2-conductor connections at the CI370 inlet.
5. Guide excess wire back through the hole in inlet bracket
and flanged fitting.
6. Refer to Figure 5. Place inlet into mounting bracket and
secure.
NOTE: When wall inlets are installed in walls that are less than 1⁄2" thick or when inlets are installed back-to-back in a wall, the tube of the wall inlet may extend into elbow area of the flanged fitting and cause blockage. Shorten the wall inlet tube to prevent this condition. Refer to Figure 6.
For extra thick walls, use Model 399 extension sleeves to connect inlet to the flanged fitting.
SCREW
TERMINAL
RED
STRIPED
WIRE
BLACK
PIG TAIL
WIRE
NUT